Corrosion:
(Salt Fog Testing) Method 509.2, 168 Hours, employed for all NEMA-4X units.
Applies to AHP-X
models
Vibration:
Method 514.3, 2 hours, x, y, z axis 8.9 G's, 10-2000 Hz with a magnitude of
0.04 G*G/Hz, Employed for all XM-Versions, Standard models are designed to
withstand 2.2 G's.
Applies to AHP-XM
models. Please Contact
us.
Shock:
Method 516.2 with 30 G's peak amplitude, 11 ms pulse duration, half-sine
waveform, and three (3) shocks in each direction along three mutually
orthogonal axes, Employed for all XM-Versions.
Applies to AHP-XM
models. Please Contact
us.
|