TECA’s
FHP
thermoelectric air conditioners are designed to mount on
the outside of the enclosure. There is no intrusion
within the enclosure allowing for greater design
flexibility. A mounting plate provides for easy
installation.

Side, Front, or Back
Mounting
This mounting orientation is recommended for
applications with high humidity or incomplete cabinet
seals. Condensation can be removed via moisture
collection systems (standard on
FHP-units and
AHP-1400) or a drip pan positioned below the cold
side fins. Drip pans are optional for thru mount style
units.
Top Mounting
It is difficult to collect condensation in this
orientation due to fin orientation and gravity. If a
drip pan is employed by the end user, use caution to
place the pan far enough away from the internal fan to
minimize the restriction of air flow. The pan should
cover the fin ends as well as the fan area. When there
is a choice, side orientation is preferred by most users
in high humidity environments. |