Liquid Cooled Thermoelectric Cold Plates For Laboratory
The cold plates on this page are designed to cool and heat, through direct contact, laboratory samples or other loads. Reaching temperatures as cold as -70C is possible with the Cascade system. RS-232 and other features are included... read more ➡ |
|
LHP-1200CPV Series
Style: Bench Top
Voltages: 100 - 240 VAC, 24 VDC
Cold Plate Temperature Range: -30 °C to 90
°C
Environments: Bench Top, Laboratory, Industrial |
Cooling capacity:
400 Watts @ 0 °C
ΔT
Includes:
Integral Power Supply
Integral Temperature control
RS-232 Communications
Remote Sensibility |
Click on part number to request a quick quote
MODEL NUMBER |
PART NUMBER |
COLD PLATE |
VOLTAGE VAC (VDC) |
CURRENT AMPS. |
COOLANT RANGE °C |
COLD PLATE RANGE C° |
LHP-1200CPV |
3-35EB-1-0A0 |
Smooth Surface |
100-240 |
6† |
0 / 50 |
-30 / 90 |
LHP-1200CPV |
3-35EB-1-TAP |
6-32 Tap Pattern |
100-240 |
6† |
0 / 50 |
-30 / 90 |
LHP-1200CPV |
3-35EB-1-MET |
M3 Tap Pattern |
100-240 |
6† |
0 / 50 |
-30 / 90 |
LHP-1200CPV |
3-35E5-1-0A0 |
Smooth Surface |
24 VDC |
25 |
0 / 50 |
-30 / 90 |
LHP-1200CPV |
3-35E5-1-TAP |
6-32 Tap Pattern |
24 VDC |
25 |
0 / 50 |
-30 / 90 |
LHP-1200CPV |
3-35E5-1-MET |
M3 Tap Pattern |
24 VDC |
25 |
0 / 50 |
-30 / 90 |
† Reflects the current draw of the unit @ 120 VAC, 60 Hz input.
Cold Plate Features:
•Precision machined cold plate surface
•Easy clean stainless steel top surface
•Cools and heats (TYP.-30 °C to 90 °C)
•100-240 VAC universal input
•Low-profile design with ergonomic sloped front
•Weighs only 25 lbs.(11.4 kg)
•Compact bench top unit,11.2”X 15.1”footprint
•Virtually maintenance-free operation
•Painted Enameled stainless steel exterior housing
•Accessories for glassware (beaker/test tube) cooling
•Many options and accessories available |
Control Features:
•Integral TC-4300 PID "tunable" temperature control
•One shot smart PID control tuning or Adaptive SmartContinuous Tuning
•EasyLog software for easy programming,tuning,chartingand data acquisition
•Heating and Cooling
•Internal RTD sensor
•Remote Sensibility™ switchable exterior sensor
•Multi-segment ramp and soak programmable(4X8 or 2X16 or 1X32 segments)
•RS-232 communications |
Click on the image for a larger view
Click on the image for larger view of the performance curve
|
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the images to open the PDF files
|
|
|
LHP-1200CPV High Temperature Series
Style: Bench Top
Voltages: 100 - 240 VAC, 24 VDC
Cold Plate Temperature Range: -30 °C to 90
°C
Environments: Bench Top, Laboratory, Industrial |
Cooling capacity:
400 Watts @ 0 °C
ΔT
Includes:
Integral Power Supply
Integral Temperature control
RS-232 Communications
Remote Sensibility |
Click on part number to request a quick quote
MODEL NUMBER |
PART NUMBER |
COLD PLATE |
VOLTAGE VAC (VDC) |
CURRENT AMPS. |
COOLANT RANGE °C |
COLD PLATE RANGE C° |
LHP-1200CPV |
3-35EB-6-0A0 |
Smooth Surface |
100-240 |
6† |
0 / 50 |
-30 / 130 |
LHP-1200CPV |
3-35EB-6-TAP |
6-32 Tap Pattern |
100-240 |
6† |
0 / 50 |
-30 / 130 |
LHP-1200CPV |
3-35EB-6-MET |
M3 Tap Pattern |
100-240 |
6† |
0 / 50 |
-30 / 130 |
LHP-1200CPV |
3-35E5-6-0A0 |
Smooth Surface |
24 VDC |
25 |
0 / 50 |
-30 / 130 |
LHP-1200CPV |
3-35E5-6-TAP |
6-32 Tap Pattern |
24 VDC |
25 |
0 / 50 |
-30 / 130 |
LHP-1200CPV |
3-35E5-6-MET |
M3 Tap Pattern |
24 VDC |
25 |
0 / 50 |
-30 / 130 |
† Reflects the current draw of the unit @ 120 VAC, 60 Hz input.
Cold Plate Features:
•Precision machined cold plate surface
•Easy clean stainless steel top surface
•Cools and heats (TYP.-30 °C to 130 °C)
•100-240 VAC universal input
•Low-profile design with ergonomic sloped front
•Weighs only 25 lbs.(11.4 kg)
•Compact bench top unit,11.2”X 15.1”footprint
•Virtually maintenance-free operation
•Painted Enameled stainless steel exterior housing
•Accessories for glassware (beaker/test tube) cooling
•Many options and accessories available |
Control Features:
•Integral TC-4300 PID "tunable" temperature control
•One shot smart PID control tuning or Adaptive SmartContinuous Tuning
•EasyLog software for easy programming,tuning,chartingand data acquisition
•Heating and Cooling
•Internal RTD sensor
•Remote Sensibility™ switchable exterior sensor
•Multi-segment ramp and soak programmable(4X8 or 2X16 or 1X32 segments)
•RS-232 communications |
Click on the image for a larger view
Click on the image for larger view of the performance curve
|
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to open the PDF file
|
|
|
LHP-1200CAS Cascade Series
Style: Bench Top
Voltages: 100 - 240 VAC, 24 VDC
Cold Plate Temperature Range: -60 °C to 90
°C
Environments: Bench Top, Laboratory, Industrial |
Maximum ΔT @ 0 Watts Load:
-54 °C for LHP-1200CAS
-72 °C for LHP-1200C22
-82 °C for LHP-1200C21
-90 °C for LHP-1200C31
Referenced 25 °C coolant flow @ 2 L/Min
Includes:
Integral Power Supply
Integral Temperature control
RS-232 Communications
Remote Sensibility |
Click on part number to request a quick quote
MODEL NUMBER |
PART NUMBER |
INCLUDED
CASCADE |
COLD PLATE
SURFACE in |
MAXIMUM
delta T °C |
VOLTAGE VAC (VDC) |
CURRENT AMPS. |
COOLANT RANGE °C |
COLD PLATE RANGE °C |
LHP-1200CAS |
3-35EB-1-CAS |
None (base model) |
13.3X5.77 |
-54 |
100-240 |
8 |
0 / 50 |
-30 / 90 |
LHP-1200C22 |
3-35EB-1-C22 |
CCP-22 |
8.75X4.50 |
-72 |
100-240 |
8.4 |
0 / 50 |
-50 / 90 |
LHP-1200C21 |
3-35EB-1-C21 |
CCP-21 |
6.0X3.0 |
-82 |
100-240 |
8.2 |
0 / 50 |
-55 / 90 |
LHP-1200C31 |
3-35EB-1-C31 |
CCP-31 |
6.0X3.0 |
-90 |
100-240 |
8.6 |
0 / 50 |
-60 / 90 |
The current draw of the unit reflect the operation in 120 VAC 60 Hz.
Cold Plate Features:
•Precision machined cold plate surface
•Easy clean stainless steel top surface
•Cools and heats (TYP.-60 °C to 90 °C)
•100-240 VAC universal input
•Low-profile design with ergonomic sloped front
•Weighs only 25 lbs.(11.4 kg)
•Compact bench top unit,11.2”X 15.1”footprint
•Virtually maintenance-free operation
•Painted Enameled stainless steel exterior housing
•Accessories for glassware (beaker/test tube) cooling
•Many options and accessories available |
Control Features:
•Integral TC-4300 PID "tunable" temperature control
•One shot smart PID control tuning or Adaptive SmartContinuous Tuning
•EasyLog software for easy programming,tuning,chartingand data acquisition
•Heating and Cooling
•Internal RTD sensor
•Remote Sensibility™ switchable exterior sensor
•Multi-segment ramp and soak programmable(4X8 or 2X16 or 1X32 segments)
•RS-232 communications |
Click on the image for a larger view
Click on the image for larger view of the performance curve
|
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to view LHP-1200CAS 3D PDF file: |
|
Click on the image to open the PDF file
|
|
|
LHP-1200CAS Cascade High Temp. Series
Style: Bench Top
Voltages: 100 - 240 VAC, 24 VDC
Cold Plate Temperature Range: -60 °C to 150
°C
Environments: Bench Top, Laboratory, Industrial |
Maximum ΔT @ 0 Watts Load:
-54 °C for LHP-1200CAS
-72 °C for LHP-1200C22
-82 °C for LHP-1200C21
-90 °C for LHP-1200C31
Referenced 25 °C coolant flow @ 2 L/Min
Includes:
Integral Power Supply
Integral Temperature control
RS-232 Communications
Remote Sensibility |
Click on part number to request a quick quote
MODEL NUMBER |
PART NUMBER |
INCLUDED
CASCADE |
COLD PLATE
SURFACE in |
MAXIMUM
delta T °C |
VOLTAGE VAC (VDC) |
CURRENT AMPS. |
COOLANT RANGE °C |
COLD PLATE RANGE °C |
LHP-1200CAS |
3-35EB-6-CAS |
None (base model) |
13.3X5.77 |
-54 |
100-240 |
8 |
0 / 50 |
-30 / 130 |
LHP-1200C22 |
3-35EB-6-C22 |
CCP-22 |
8.75X4.50 |
-72 |
100-240 |
8.4 |
0 / 50 |
-50 / 150 |
LHP-1200C21 |
3-35EB-6-C21 |
CCP-21 |
6.0X3.0 |
-82 |
100-240 |
8.2 |
0 / 50 |
-55 / 150 |
LHP-1200C31 |
3-35EB-6-C31 |
CCP-31 |
6.0X3.0 |
-90 |
100-240 |
8.6 |
0 / 50 |
-60 / 150 |
The current draw of the unit reflect the operation in 120 VAC 60 Hz.
Cold Plate Features:
•Precision machined cold plate surface
•Easy clean stainless steel top surface
•Cools and heats (TYP.-60 °C to 150 °C)
•100-240 VAC universal input
•Low-profile design with ergonomic sloped front
•Weighs only 25 lbs.(11.4 kg)
•Compact bench top unit,11.2”X 15.1”footprint
•Virtually maintenance-free operation
•Painted Enameled stainless steel exterior housing
•Accessories for glassware (beaker/test tube) cooling
•Many options and accessories available |
Control Features:
•Integral TC-4300 PID "tunable" temperature control
•One shot smart PID control tuning or Adaptive SmartContinuous Tuning
•EasyLog software for easy programming,tuning,chartingand data acquisition
•Heating and Cooling
•Internal RTD sensor
•Remote Sensibility™ switchable exterior sensor
•Multi-segment ramp and soak programmable(4X8 or 2X16 or 1X32 segments)
•RS-232 communications |
Click on the image for a larger view
Click on the image for larger view of the performance curve
|
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to view LHP-1200CAS 3D PDF file: |
|
Click on the image to open the PDF file
|
|
|
CCP-22 Cascade Cold Plate
Description: Low Temperature Cascade
Voltages: 24 VDC
Cascade Temperature Range: -30 °C to 90
°C
Requirement:
AHP-1200CPV for Cascades Part Number: 9-35EB-1-CAS |
Applications:
Laboratory or industrial environments, drugs and industrial chemicals. Process testing. Quality control.
Includes:
Internal RTD Sensor |
Click on the image for a larger view
Shown above CCP-22 cascade and CCP-22 cascade mounted on AHP-1200CPV CAS.
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to view CCP-22 3D PDF file: |
|
Click on the image to open the PDF file
|
|
|
CCP-22H High Temp. Cascade Cold Plate
Description: Extended Temperature Cascade
Voltages: 24 VDC
Cascade Temperature Range: -30 °C to 150
°C
Requirement:
AHP-1200CPV for Cascades Part Number: 9-35EB-6-CAS |
Applications:
Laboratory or industrial environments, drugs and industrial chemicals. Process testing. Quality control.
Includes:
Internal RTD Sensor |
Click on the image for a larger view
Shown above CCP-22 cascade and CCP-22 cascade mounted on AHP-1200CPV CAS.
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to view CCP-22 3D PDF file: |
|
Click on the image to open the PDF file
|
|
|
CCP-21 Cascade Cold Plate
Description: Low Temperature Cascade
Voltages: 24 VDC
Cascade Temperature Range: -40 °C to 90
°C
Requirement:
AHP-1200CPV for Cascades Part Number: 9-35EB-1-CAS |
Applications:
Laboratory or industrial environments, drugs and industrial chemicals. Process testing. Quality control.
Includes:
Internal RTD Sensor |
Click on the image for a larger view
Shown above CCP-21 low termperature cascade and CCP-21 mounted on AHP-1200CPV CAS.
Click for larger view of the performance curve
|
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to view CCP-21 3D PDF file: |
|
Click on the image to open the PDF file
|
|
|
CCP-21H High Temp. Cascade Cold Plate
Description: Extended Temperature Cascade
Voltages: 24 VDC
Cascade Temperature Range: -40 °C to 150
°C
Requirement:
AHP-1200CPV for Cascades Part Number: 9-35EB-6-CAS |
Applications:
Laboratory or industrial environments, drugs and industrial chemicals. Process testing. Quality control.
Includes:
Internal RTD Sensor |
Click on the image for a larger view
Shown above CCP-21 low termperature cascade and CCP-21 mounted on AHP-1200CPV CAS.
Click for larger view of the performance curve
|
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to view CCP-21 3D PDF file: |
|
Click on the image to open the PDF file
|
|
|
CCP-31 Cascade Cold Plate
Description: Low Temperature Cascade
Voltages: 24 VDC & 12 VDC
Cascade Temperature Range: -50 °C to 90
°C
Requirement:
AHP-1200CPV for Cascades Part Number: 9-35EB-1-CAS |
Applications:
Laboratory or industrial environments, drugs and industrial chemicals. Process testing. Quality control.
Includes:
Internal RTD Sensor |
Click on the image for a larger view
Shown above CCP-31 low termperature cascade and CCP-31 mounted on AHP-1200CPV CAS with CH-1200 hinged cover accessory.
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to view CCP-31 3D PDF file: |
|
Click on the image to open the PDF file
|
|
|
CCP-31H High Temp. Cascade Cold Plate
Description: Extended Temperature Cascade
Voltages: 24 VDC & 12 VDC
Cascade Temperature Range: -50 °C to 150
°C
Requirement:
AHP-1200CPV for Cascades Part Number: 9-35EB-6-CAS |
Applications:
Laboratory or industrial environments, drugs and industrial chemicals. Process testing. Quality control.
Includes:
Internal RTD Sensor |
Click on the image for a larger view
Shown above CCP-31 low termperature cascade and CCP-31 mounted on AHP-1200CPV CAS with CH-1200 hinged cover accessory.
Click on the image for a larger view
View or request 3D solid model files for this product:
Click on the image to view CCP-31 3D PDF file: |
|
Click on the image to open the PDF file
|
|
|
TECA's thermoelectric (Peltier) Liquid-Cooled Laboratory Cold/Hot Plates are perfect for use in laboratories or anywhere solid-state cooling or heating surfaces are needed. Applications include cooling and heating lab samples, tissue dissection (histology), quality control, pharmaceuticals, research, pain studies (thermal nociception) and more.
Each thermoelectric Cold/Hot plate (Peltier cold/hot plate) on this page include versatile features such as: integral programmable temperature controller, data logging software, RS-232 communications, integral RTD sensor, ability to swith to exterior sensor, and more.
Cold/Hot Plate surfaces can be smooth or include tapped accessory holes at no extra charge (see drawing). Accessories are available to help you further customize the plate to your application.
High temperature versions are available for heating above 90C. Ultra-low temperatures can be attained with a liquid cooled cascade system, the theromelectric LHP-1200CAS Cold/Hot Plate. |
|
|
|
|
|
|