Style: Bench Top, Laboratory
Voltage: 100-240 VAC
Current: 2.2-1.0 AMPS
Operating Ambient: 0/+45 °C
Requirements:
The AHP-301MSP must be used with one of the SLV-XXXMSP Cold Shoe accessories.
• SLV-XXXMSP Sleeve accessory for direct contact cooling/heating of specific beakers and vessels.
Includes:
• Integral Power Supply
• Integral PWM Temperature control
• USB comms port
• Remote Sensibility
Controller Features:
• Integral “tunable” PWM temperature control
• PWM, Bi-directional temperature control
• 4 Temperature zone with 4 independent PID settings
• Multi-segment ramp and soak programmable
• Internal RTD sensor
• Remote Sensibility™ switchable to exterior accessory RTD sensor
• USB Communication with easy-to-use software
• Labview VI examples
- Click on the part numbers to request a quick quote:
MODEL NUMBER | PART NUMBER | VOLTAGE
VAC (VDC) | CURRENT
AMPS |
AHP-301MSP | 9-70KB-1-MSP
| 100-240 | 2.2-1.0 |
The AHP-301MSP must be used with one of the SLV-XXXMSP Cold Shoe accessories.
SLV-XXXMSP Sleeve accessories part numbers and specifications:
PART NUMBER |
BEAKER
TYPE |
VOLUME
mL |
DIAMETER
in [mm] |
TT PAD
RQD. |
SLV-600MSP
|
Griffin Low Form |
600 |
3.54 [90] |
_ |
|
Griffin Low Form |
500 |
3.35 [85] |
TT-G500 |
|
Berzelius Tall Form |
800 |
3.54 [90] |
TT-B800 |
SLV-400MSP
|
Griffin Low Form |
400 |
3.15 [80] |
_ |
|
Berzelius Tall Form |
500 |
3.11 [79] |
TT-B500 |
|
Berzelius Tall Form |
600 |
3.15 [80] |
TT-B600 |
SLV-250MSP
|
Griffin Low Form |
250 |
2.75 [70] |
_ |
|
Berzelius Tall Form |
400 |
2.75 [70] |
TT-B400 |
SLV-150MSP
|
Griffin Low Form |
150 |
2.36 [60] |
_ |
|
Berzelius Tall Form |
250 |
2.36 [60] |
TT-B250 |
SLV-100MSP
|
Griffin Low Form |
100 |
1.97 [50] |
_ |
|
Berzelius Tall Form |
100 |
1.89 [48] |
TT-B100 |
- Click to download:
Product Manuals, Software:
PART NUMBER |
BEAKER
TYPE |
VOLUME
mL |
DIAMETER
in [mm] |
TT PAD
RQD. |
SLV-600MSP |
Griffin Low Form |
600 |
3.54 [90] |
_ |
|
Griffin Low Form |
500 |
3.35 [85] |
TT-G500 |
|
Berzelius Tall Form |
800 |
3.54 [90] |
TT-B800 |
SLV-400MSP |
Griffin Low Form |
400 |
3.15 [80] |
_ |
|
Berzelius Tall Form |
500 |
3.11 [79] |
TT-B500 |
|
Berzelius Tall Form |
600 |
3.15 [80] |
TT-B600 |
SLV-250MSP |
Griffin Low Form |
250 |
2.75 [70] |
_ |
|
Berzelius Tall Form |
400 |
2.75 [70] |
TT-B400 |
SLV-150MSP |
Griffin Low Form |
150 |
2.36 [60] |
_ |
|
Berzelius Tall Form |
250 |
2.36 [60] |
TT-B250 |
SLV-100MSP |
Griffin Low Form |
100 |
1.97 [50] |
_ |
|
Berzelius Tall Form |
100 |
1.89 [48] |
TT-B100 |
Features:
• PWM temperature control
• Fluid process temperature range 0 °C to 50 °C
• Internal and external RTD sensor
• Adjustable stirring from 100 to 1000 RPM
• Accommodates many vessel sizes
• Stainless steel, aluminum and acrylic construction
• Certified to CSA STDS C22.2 # 61010-1 & 61010-2-010
• FCC 47CFR PT 15: 2019; IEC 61326-1
Resources:
Cold Plate Notes
Applications
Accessories
Manuals