Thermoelectric Air Conditioners for Nema-4X/Harsh Environment/Military harsh environment:
This page identifies the TECA Air Conditioner models which are available for installation in a NEMA-4X/Harsh Environment cabinet. These use Mil-Std 810 fans and are ideal for corrosive environments, such as salt spray and blowing sand.
As you browse, please note that NEMA-4X/Harsh Environment air conditioners have a suffix of “X” or “XHC”. Air conditioners suited to NEMA-4X/Harsh Environment and Full Shock & Vibration have the suffix “XM” or “XMHC”. The NEMA definitions are below. Please call TECA anytime with your questions!
Click on any column to sort the below matrix by column header.
Model Number | Mounting Style | Cooling Capacity BTU/HR | COP | Voltage VAC (VDC) | Current AMPS |
---|---|---|---|---|---|
FHP-250X | Flush | 109 | 0.44 | (12, 24) | 6, 3 |
AHP-250X | Through | 130 | 0.53 | (12, 24) | 6, 3 |
FHP-270X | Flush | 140 | 0.42 | (12, 24) | 8.3, 4.1 |
AHP-270X | Through | 160 | 0.46 | (12, 24) | 8.3, 4.1 |
FHP-470X | Flush | 259 | 0.48 | (24) | 7 |
AHP-470X | Through | 315 | 0.56 | (24) | 7 |
IHP-470X | Internal | 228 | 0.4 | (24) | 7 |
IHP-590X | Internal | 315 | 0.56 | (24) | 7 |
AHP-590X | Through | 460 | 0.85 | (24, 48) | 7, 3.5 |
AHP-690X | Through | 467 | 0.52 | (24, 48) | 15, 7 |
AHP-1200X | Through | 530 | 0.71 | 120, 240, (24, 48) | 4.5, 2.5, (9, 4.5) |
FHP-590X | Flush | 416 | 0.75 | (24, 48) | 7, 3.5 |
AHP-1300X | Through | 760 | 0.84 | (24) | 11 |
AHP-1800X | Through | 1100 | 0.74 | 120, 240, (24, 48) | 8, 5, (18, 9) |
AHP-2250X Hi. Eff. | Through | 1400 | 0.95 | 120, (24, 48) | 3.6, (15, 7.5) |
FHP-2250X Hi. Eff. | Flush | 1220 | 0.83 | 120, (24, 48) | 3.6, (15, 7.5) |
AHP-2250X Hi. Cap. | Through | 1880 | 0.42 | 120, (48) | 10.8, (15) |
AHP-3250X | Through | 2250 | 0.78 | 120, (48) | 7, (22) |
AHP-4250X | Through | 2490 | 0.98 | 120, (48) | 6, (16) |
FHP-2250X Hi. Cap. | Flush | 1715 | 0.39 | 120, (48) | 10.8, (15) |
FHP-3250X | Flush | 1978 | 0.7 | 120, (48) | 7, (22) |
FHP-4250X | Flush | 2408 | 0.98 | 120, (48) | 6, (16) |
AHP-2252X | Through | 2060 | 0.4 | 240 | 6.5 |
AHP-3252X | Through | 2610 | 0.7 | 240 | 4.6 |
AHP-4252X Hi. Eff. | Through | 2780 | 0.85 | 240 | 4 |
FHP-2252X hi. Cap | Flush | 1875 | 0.35 | 240 | 6.5 |
FHP-3252X | Flush | 2290 | 0.61 | 240 | 4.6 |
FHP-4252X Hi. Eff. | Flush | 2615 | 0.8 | 240 | 4 |
AHP-3254X | Through | 2686 | 0.84 | 208 (3 PH, Wye) | 2.6 |
AHP-3253X | Through | 2973 | 0.72 | 240 (3 PH, Delta) | 2.9 |
FHP-3254X | Flush | 2235 | 0.61 | 208 ( 3PH, Wye) | 2.6 |
FHP-3253X | Flush | 2593 | 0.63 | 240 (3 PH, Delta) | 2.9 |
AHP-4252X Hi. Cap. | Through | 3810 | 0.37 | 240 | 12.5 |
FHP-4252X Hi. Cap. | Flush | 3615 | 0.35 | 240 | 12.5 |
AHP-6250X | Through | 4340 | 0.76 | 120, (48) | 14, (25) |
FHP-6250X | Flush | 3820 | 0.67 | 120, (48) | 14, (25) |
FHP-6252X | Flush | 4480 | 0.6 | 240 | 9.2 |
FHP-6253X | Flush | 4830 | 0.62 | 240 (3 PH, Delta) | 5.5 |
FHP-6263X | Flush | 4970 | 0.32 | 240 (3 PH. Delta) | 11 |
AHP-6252X | Through | 5196 | 0.7 | 240 | 9.2 |
AHP-6253X | Through | 5080 | 0.7 | 240 (3 PH. Delta) | 5.5 |
AHP-6263X | Through | 5660 | 0.36 | 240 (3 PH, Delta) | 11 |
NEMA-12: Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids.
Source: NEMA Publication N0. 250, Part 1, Page 1
Applies to prefix AHP, LHP, IHP & FHP air conditioner models.
NEMA-4: Type 4 enclosures are intended for indoor and outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, and hose directed water. TECA products with the “XE” designation use sealed fans, sealed components, stud/gasket mounting and Mil- Spec finishes. They are designed to maintain the enclosure rating and perform in the rated environment. Source: NEMA Publication N0. 250, Part 1, Page 1
Applies to suffix XE air conditioner models.
NEMA-4X/Harsh Environment: Type 4X enclosures are intended for indoor and outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose directed water. TECA products carrying the “X” designation use Mil-Spec fans, o-ring sealed power supplies, no exposed electronic components, stud/gasket mounting and Mil-Spec finishes. They are designed to maintain the enclosure rating and perform in the rated environment. Source: NEMA Publication N0. 250, Part 1, Page 1
Applies to suffix X air conditioner models.
IP Ratings: “IP” refers to “Ingress Protection”, a standard recognized largely in Europe and internationally. While the IP Ratings and NEMA Ratings do not correlate exactly, there are similarities. TECA air conditioners indicate on each product specification sheet the NEMA rating and most similar IP rating. For a summary on IP ratings, please see our Design Considerations page and click the “IP” tab (second tab down).
Contact TECA sales anytime with your questions, 773-342-4900
Mounting Styles:
Resources: