AHP-3259

High Capacity Thermoelectric Air Conditioner

  • Mounting Style: Through Mounted
    Voltage: 100-240 VAC
    Current: 11-4.6 AMPS
    Operating Ambient: -40/+65 °C
    Operating Enclosure: -10/+60 °C
    Environments: Nema-12, Nema-4

    Performance Rating:
    Cooling (Traditional):
    2400 BTU/HR
    Cooling (Din 3168): 705 WATTS
    Cooling COP (at L35 L35): 0.64
    Heating (Traditional): >1200 BTU/HR
    Heating (Din 3168): >352 WATTS
    Heating COP: >1.0

    Includes:
    • Power supply
    • Temperature controller
    • Power saving heat exchanger mode (ECO-Mode)
    • Mounting gasket
    • Mounting hardware
    • Power input cord

    Controller Features:
    TC-4F: Active cool 35 °C; ECO-Mode 25 °C
    TC-7F: Active cool 35 °C; Active heat 15 °C; ECO-Mode 25 °C

  • Click on the part numbers to request a quick quote:
    MODEL NUMBERPART NUMBERNOTESCONTROLLERENVIRONMENT
    AHP-32590-I5JB-0-000
    Cool onlyTC-4FNEMA-12, IP 52
    AHP-32590-I55B-0-000
    Cool only5-32 VDC external signalNEMA-12, IP 52
    AHP-3259HC0-I5IB-1-000
    Heat/CoolTC-7FNEMA-12, IP 52
    AHP-3259HC0-I55B-1-000
    Heat/Cool5-32 VDC external signalNEMA-12, IP 52
    AHP-3259XE0-I5JB-4-000
    Cool onlyTC-4FNEMA-4/4X, IP 56
    AHP-3259XE0-I55B-4-000
    Cool only5-32 VDC external signalNEMA-4/4X, IP 56
    AHP-3259XEHC0-I5IB-5-000
    Heat/CoolTC-7FNEMA-4/4X, IP 56
    AHP-3259XEHC0-I55B-5-000
    Heat/Cool5-32 VDC external signalNEMA-4/4X, IP 56
    AHP-3259HC0-I5LB-5-000
    Heat/CoolTC-5300D PWM controlNEMA-12, IP 52
    AHP-3259XEHC0-I5LB-5-000
    Heat/CoolTC-5300D PWM controlNEMA-4/4X, IP 56
  • Click to download:

    Solid Model files:
    TypeFile NameDate ModifiedSize

    IGS
    AHP 3259 8:36 am 11/04/201665.1M

    PDF
    AHP 3259 8:35 am 11/04/20165.6M

    SLDP
    AHP 3259 8:36 am 11/04/201620.8M

    STEP
    AHP 3259 8:36 am 11/04/201641M
  • Part NumberDescriptionDrawingData Sheet
    EH-2001200 Watts Enclosure heater
    120 VAC
    dwgpdf
    EH-2002200 Watts Enclosure heater
    240 VAC
    dwgpdf
    EH-4001400 Watts Enclosure heater
    120 VAC
    dwgpdf
    EH-4002400 Watts Enclosure heater
    240 VAC
    dwgpdf
    DVA-3200Drip pan, vertical cold side finsdwgpdf
    DHA-3200Drip pan, horizontal cold side finsdwgpdf
    D-100Condensate discharge, plasticpdf
    D-200Condensate discharge, ST.ST.pdf

Features:
• 90-264 VAC Universal input power supply
• High capacity thermoelectric design
• Power saving air to air heat exchanger mode (ECO-Mode)
• Heavy duty full perimeter mounting
• Lower profile intrusion into enclosure
• Central input cord for easy mounting
• Closed loop design
• Condensate control and evaporation system
• Compact
• Increased efficiency at higher ambient by as much as 10%
• Virtually maintenance free
• No compressor
• Environmentally friendly and safe
• Stainless Steel exterior housing
• Mounts and operates in any orientation
• Integral temperature controller
• Weight 82 LBS.


Resources:

Air conditioner Notes

Applications

Accessories

Manuals

Sizing Software

Contact Us

Internally Mounted, AC Input Air Conditioner

TECA Launches line of internally mounted, AC-input Air Conditioners:

The IHP-2259 is TECA’s first internally-mounted thermoelectric air conditioner with universal 100-240 VAC input.

Read more

Largest Cold Plate Surface

New Cold/Hot Plate with Largest Plate Surface to Date:

TECA now offers a 690 watt product with a 13.3 x 20.3 inch flat plate surface for heating and cooling. See New, Even Larger AHP-5400CPV!

Read more

AHP-2259 High Capacity

High Capacity Thermoelectric Air Conditioner

  • Mounting Style: Through Mounted
    Voltage: 100-240 VAC
    Current: 8.4-3.5 AMPS
    Operating Ambient: -40/+65 °C
    Operating Enclosure: -10/+60 °C
    Environments: Nema-12, Nema-4

    Performance Rating:
    Cooling (Traditional):
    1820 BTU/HR
    Cooling (Din 3168): 534 WATTS
    Cooling COP (at L35 L35): 0.65
    Heating (Traditional): >2780 BTU/HR
    Heating (Din 3168): >816 WATTS
    Heating COP: >1.0

    Includes:
    • Power supply
    • Temperature controller
    • Power saving heat exchanger mode (ECO-Mode)
    • Mounting gasket
    • Mounting hardware
    • Power input cord

    Controller Features:
    TC-4F: Active cool 35 °C; ECO-Mode 25 °C
    TC-7F: Active cool 35 °C; Active heat 15 °C; ECO-Mode 25 °C

  • Click on the part numbers to request a quick quote:
    MODEL NUMBERPART NUMBERNOTESCONTROLLERENVIRONMENT
    AHP-22590-H5JB-0-000
    Cool onlyTC-4FNEMA-12, IP 52
    AHP-22590-H55B-0-000
    Cool only5-32 VDC external signalNEMA-12, IP 52
    AHP-2259HC0-H5IB-1-000
    Heat/CoolTC-7FNEMA-12, IP 52
    AHP-2259HC0-H55B-1-000
    Heat/Cool5-32 VDC external signalNEMA-12, IP 52
    AHP-2259XE0-H5JB-4-000
    Cool onlyTC-4FNEMA-4/4X, IP 56
    AHP-2259XE0-H55B-4-000
    Cool only5-32 VDC external signalNEMA-4/4X, IP 56
    AHP-2259XEHC0-H5IB-5-000
    Heat/CoolTC-7FNEMA-4/4X, IP 56
    AHP-2259XEHC0-H55B-5-000
    Heat/Cool5-32 VDC external signalNEMA-4/4X, IP 56
  • Click to download:

    Solid Model files:
    TypeFile NameDate ModifiedSize

    IGS
    AHP 2259 8:52 am 09/01/201650.6M

    PDF
    AHP 2259 8:52 am 09/01/20162.2M

    SLDP
    AHP 2259 8:52 am 09/01/201615.5M

    STEP
    AHP 2259 8:53 am 09/01/201632.1M
  • Part NumberDescriptionFor use with air conditioner seriesDrawingData Sheet
    EH-2001200 Watts Enclosure heater
    120 VAC
    dwgpdf
    EH-2002200 Watts Enclosure heater
    240 VAC
    dwgpdf
    EH-4001400 Watts Enclosure heater
    120 VAC
    dwgpdf
    EH-4002400 Watts Enclosure heater
    240 VAC
    dwgpdf
    DVA-2200Drip pan, vertical cold side finsAHP-2200dwgpdf
    DHA-2200Drip pan, horizontal cold side finsAHP-2200dwgpdf
    D-100Condensate discharge, plasticpdf
    D-200Condensate discharge, ST.ST.pdf
    SP500-24Switching power supply
    500 Watts, 24 VDC
    pdf
    SP800-24Switching power supply
    800 Watts, 24 VDC
    pdf

Features:
• 90-264 VAC Universal input power supply
• High efficiency thermoelectric design
• Power saving air to air heat exchanger mode (ECO-Mode)
• Heavy duty full perimeter mounting
• Lower profile intrusion into enclosure
• Central input cord for easy mounting
• Closed loop design
• Condensate control and evaporation system
• Compact
• Increased efficiency at higher ambients by as much as 10%
• Virtually maintenance free
• No compressor
• Environmentaly friendly and safe
• Stainless Steel exterior housing
• Mounts and operates in any orientation
• Integral temperature controller
• Weight 60 LBS.


Resources:

Air conditioner Notes

Applications

Accessories

Manuals

Sizing Software

Contact Us

GAS CHROMATOGRAPHY SYSTEM

Gas Chromatography System:

Gas Chromatography System
Gas Chromatography System Gas Chromatography System

 

TECA Model AHP-1801XPHC-1 Thermoelectric Air Conditioner is used to enable the safe installation of a gas chromatography system into hazardous locations. Most installations are rated Class 1, Groups C & D, Division II. However in some cases the installations require Group B and/or Group A. TECA’s AHP-1801XPHC-1 maintains the interior of the Process Analyzer Enclosure at a control temperature of around 70o °F.  It meets the various requirements of all the installation environments.

This system is installed in Refining, Petrochemical, Upstream and other applications requiring the aforementioned safety ratings. Controlling the temperature of the equipment enclosure rather than the entire shelter allows for far more economical plant installations even in very cold or very hot environments.

Our customer reports:
“Simply protecting our Process Analyzer Enclosure from direct sunlight and precipitation is enough using the AHP-1801XPHC-1.  The TECA Air Conditioner has plenty of capacity to handle the most demanding environments such as the Texas Gulf Coast and even in Alberta, CA. See the actual plant installation picture where 3 Process Enclosures are shown. The TECA Air Conditioners are clearly evident below each analyzer.  These units have been in operation for more than 2 years without maintenance, without downtime.  This says a lot about the capability and capacity of the TECA product in a tough environment.  And the analyzers have performed flawlessly delivering control quality composition data to the plant process control computer.

TIGHT TEMPERATURE CONTROL

Tight Temperature Control Within Small Enclosure:

tight temperature control 172-ahp-301ff

 

A manufacturer of specialty materials required cooling and heating of small enclosures. The system pictured here is used for the mixing of helium and hydrogen with dew point control.

TECA Model AHP-301FFHC is used with a TECA PID temperature controller to regulate the temperature of the enclosure in order to establish the moisture content of the “wet gas”, which is blended with dry gas to fix the dew point by way of the Buck Equation.

The customer is pleased with the results and continues to build more systems using TECA air conditioners and temperature controllers.

the AHP-301FF series is now replaced by newer model the AHP-401 series.

COOLING LARGER ENCLOSURES

Cooling Larger enclosures Than Ever Before:

cooling larger enclosures

A user of the Model AHP-6250 Solid-State Air Conditioner gives a wonderful example of the benefit of TECA’s newly introduced line of high-capacity thermoelectric air conditioners.

Designed to cool larger enclosures than was previously practical with thermoelectric technology, the AHP-6250 is one of the largest models in this group. For example, the enclosure pictured here is about 8 x 6 x 3 feet. The customer is able to achieve large enclosure cooling with a single thermoelectric air conditioner. Thermoelectric cooling is reliable and maintenance free.

TECA’s new high-capacity line has some thoughtful design features, as seen pictured here on the installed AHP-6250. The cold side (internal to enclosure) has a low profile, which translates into less intrusion into the enclosure, giving the user more room for whatever the enclosure is meant to hold. The robust mounting flange, gasket and hardware and centrally located power input contribute to user-friendly installation. Finally, high air-flow fans and high fin-density heat sinks on the cold side maximize performance and minimize condensation. An integral condensate removal system absorbs condensation and transports it to the hot side, where it gets evaporated into the ambient.

COMMUNICATIONS

Communications, Cooling Battery Bank:

communications communications

 

Maintain the temperature of a battery bank in a Class 1 Division 2 explosion proof environment to power portable communications equipment. A special purpose vehicle manufacturer needed to maintain the temperature of a bank of batteries to maintain maximum performance.

With our recommendation, the customer selected the TECA Model AHP-1800XP, because it is the only NEMA4X air conditioner available off-the-shelf, which is also certified for C1D2 use. The power source was able to meet the requirement of operation in a Class 1 Division 2 explosion proof environment, to support portable communications systems at car racing venues.

HAZARDOUS ENVIRONMENT

Hazardous Environment:

hazardous environment

A custom design solution based on a standard thermoelectric air conditioner AHP-1801X was developed to meet European hazardous environment specification (ATEX) for a customer that was in need of such a system in a very short time.

Quarterly eNewsletter