Enclosure Cooling with Universal Input Voltage:
The newly released AHP-3259 Series of thermoelectric air conditioners will automatically accept 90 to 264 VRMS input.
High Capacity Thermoelectric Air Conditioner
Mounting Style: Through Mounted
Voltage: 100-240 VAC
Current: 11-4.6 AMPS
Operating Ambient: -40/+65 °C
Operating Enclosure: -10/+60 °C
Environments: ,
Performance Rating:
Cooling (Traditional): 2400 BTU/HR
Cooling (Din 3168): 705 WATTS
Cooling COP (at L35 L35): 0.64
Heating (Traditional): >1200 BTU/HR
Heating (Din 3168): >352 WATTS
Heating COP: >1.0
Includes:
• Power supply
• Temperature controller
• Power saving heat exchanger mode (ECO-Mode)
• Mounting gasket
• Mounting hardware
• Power input cord
Controller Features:
TC-4F: Active cool 35 °C; ECO-Mode 25 °C
TC-7F: Active cool 35 °C; Active heat 15 °C; ECO-Mode 25 °C
MODEL NUMBER | PART NUMBER | NOTES | CONTROLLER | ENVIRONMENT |
---|---|---|---|---|
AHP-3259 | 0-I5JB-0-000 | Cool only | TC-4F | NEMA-12, IP 52 |
AHP-3259 | 0-I55B-0-000 | Cool only | 5-32 VDC external signal | NEMA-12, IP 52 |
AHP-3259HC | 0-I5IB-1-000 | Heat/Cool | TC-7F | NEMA-12, IP 52 |
AHP-3259HC | 0-I55B-1-000 | Heat/Cool | 5-32 VDC external signal | NEMA-12, IP 52 |
AHP-3259XE | 0-I5JB-4-000 | Cool only | TC-4F | NEMA-4/4X, IP 56 |
AHP-3259XE | 0-I55B-4-000 | Cool only | 5-32 VDC external signal | NEMA-4/4X, IP 56 |
AHP-3259XEHC | 0-I5IB-5-000 | Heat/Cool | TC-7F | NEMA-4/4X, IP 56 |
AHP-3259XEHC | 0-I55B-5-000 | Heat/Cool | 5-32 VDC external signal | NEMA-4/4X, IP 56 |
AHP-3259HC | 0-I5LB-5-000 | Heat/Cool | TC-5300D PWM control | NEMA-12, IP 52 |
AHP-3259XEHC | 0-I5LB-5-000 | Heat/Cool | TC-5300D PWM control | NEMA-4/4X, IP 56 |
Features:
• 90-264 VAC Universal input power supply
• High capacity thermoelectric design
• Power saving air to air heat exchanger mode (ECO-Mode)
• Heavy duty full perimeter mounting
• Lower profile intrusion into enclosure
• Central input cord for easy mounting
• Closed loop design
• Condensate control and evaporation system
• Compact
• Increased efficiency at higher ambient by as much as 10%
• Virtually maintenance free
• No compressor
• Environmentally friendly and safe
• Stainless Steel exterior housing
• Mounts and operates in any orientation
• Integral temperature controller
• Weight 82 LBS.
Resources:
TECA now offers a 690 watt product with a 13.3 x 20.3 inch flat plate surface for heating and cooling. See New, Even Larger AHP-5400CPV!
High Capacity Thermoelectric Air Conditioner
Mounting Style: Through Mounted
Voltage: 100-240 VAC
Current: 8.4-3.5 AMPS
Operating Ambient: -40/+65 °C
Operating Enclosure: -10/+60 °C
Environments: ,
Performance Rating:
Cooling (Traditional): 1820 BTU/HR
Cooling (Din 3168): 534 WATTS
Cooling COP (at L35 L35): 0.65
Heating (Traditional): >2780 BTU/HR
Heating (Din 3168): >816 WATTS
Heating COP: >1.0
Includes:
• Power supply
• Temperature controller
• Power saving heat exchanger mode (ECO-Mode)
• Mounting gasket
• Mounting hardware
• Power input cord
Controller Features:
TC-4F: Active cool 35 °C; ECO-Mode 25 °C
TC-7F: Active cool 35 °C; Active heat 15 °C; ECO-Mode 25 °C
MODEL NUMBER | PART NUMBER | NOTES | CONTROLLER | ENVIRONMENT |
---|---|---|---|---|
AHP-2259 | 0-H5JB-0-000 | Cool only | TC-4F | NEMA-12, IP 52 |
AHP-2259 | 0-H55B-0-000 | Cool only | 5-32 VDC external signal | NEMA-12, IP 52 |
AHP-2259HC | 0-H5IB-1-000 | Heat/Cool | TC-7F | NEMA-12, IP 52 |
AHP-2259HC | 0-H55B-1-000 | Heat/Cool | 5-32 VDC external signal | NEMA-12, IP 52 |
AHP-2259XE | 0-H5JB-4-000 | Cool only | TC-4F | NEMA-4/4X, IP 56 |
AHP-2259XE | 0-H55B-4-000 | Cool only | 5-32 VDC external signal | NEMA-4/4X, IP 56 |
AHP-2259XEHC | 0-H5IB-5-000 | Heat/Cool | TC-7F | NEMA-4/4X, IP 56 |
AHP-2259XEHC | 0-H55B-5-000 | Heat/Cool | 5-32 VDC external signal | NEMA-4/4X, IP 56 |
Features:
• 90-264 VAC Universal input power supply
• High efficiency thermoelectric design
• Power saving air to air heat exchanger mode (ECO-Mode)
• Heavy duty full perimeter mounting
• Lower profile intrusion into enclosure
• Central input cord for easy mounting
• Closed loop design
• Condensate control and evaporation system
• Compact
• Increased efficiency at higher ambients by as much as 10%
• Virtually maintenance free
• No compressor
• Environmentaly friendly and safe
• Stainless Steel exterior housing
• Mounts and operates in any orientation
• Integral temperature controller
• Weight 60 LBS.
Resources:
TECA Model AHP-1801XPHC-1 Thermoelectric Air Conditioner is used to enable the safe installation of a gas chromatography system into hazardous locations. Most installations are rated Class 1, Groups C & D, Division II. However in some cases the installations require Group B and/or Group A. TECA’s AHP-1801XPHC-1 maintains the interior of the Process Analyzer Enclosure at a control temperature of around 70o °F. It meets the various requirements of all the installation environments.
This system is installed in Refining, Petrochemical, Upstream and other applications requiring the aforementioned safety ratings. Controlling the temperature of the equipment enclosure rather than the entire shelter allows for far more economical plant installations even in very cold or very hot environments.
Our customer reports:
“Simply protecting our Process Analyzer Enclosure from direct sunlight and precipitation is enough using the AHP-1801XPHC-1. The TECA Air Conditioner has plenty of capacity to handle the most demanding environments such as the Texas Gulf Coast and even in Alberta, CA. See the actual plant installation picture where 3 Process Enclosures are shown. The TECA Air Conditioners are clearly evident below each analyzer. These units have been in operation for more than 2 years without maintenance, without downtime. This says a lot about the capability and capacity of the TECA product in a tough environment. And the analyzers have performed flawlessly delivering control quality composition data to the plant process control computer.
A manufacturer of specialty materials required cooling and heating of small enclosures. The system pictured here is used for the mixing of helium and hydrogen with dew point control.
TECA Model AHP-301FFHC is used with a TECA PID temperature controller to regulate the temperature of the enclosure in order to establish the moisture content of the “wet gas”, which is blended with dry gas to fix the dew point by way of the Buck Equation.
The customer is pleased with the results and continues to build more systems using TECA air conditioners and temperature controllers.
the AHP-301FF series is now replaced by newer model the AHP-401 series.
A user of the Model AHP-6250 Solid-State Air Conditioner gives a wonderful example of the benefit of TECA’s newly introduced line of high-capacity thermoelectric air conditioners.
Designed to cool larger enclosures than was previously practical with thermoelectric technology, the AHP-6250 is one of the largest models in this group. For example, the enclosure pictured here is about 8 x 6 x 3 feet. The customer is able to achieve large enclosure cooling with a single thermoelectric air conditioner. Thermoelectric cooling is reliable and maintenance free.
TECA’s new high-capacity line has some thoughtful design features, as seen pictured here on the installed AHP-6250. The cold side (internal to enclosure) has a low profile, which translates into less intrusion into the enclosure, giving the user more room for whatever the enclosure is meant to hold. The robust mounting flange, gasket and hardware and centrally located power input contribute to user-friendly installation. Finally, high air-flow fans and high fin-density heat sinks on the cold side maximize performance and minimize condensation. An integral condensate removal system absorbs condensation and transports it to the hot side, where it gets evaporated into the ambient.
Maintain the temperature of a battery bank in a Class 1 Division 2 explosion proof environment to power portable communications equipment. A special purpose vehicle manufacturer needed to maintain the temperature of a bank of batteries to maintain maximum performance.
With our recommendation, the customer selected the TECA Model AHP-1800XP, because it is the only NEMA4X air conditioner available off-the-shelf, which is also certified for C1D2 use. The power source was able to meet the requirement of operation in a Class 1 Division 2 explosion proof environment, to support portable communications systems at car racing venues.
A custom design solution based on a standard thermoelectric air conditioner AHP-1801X was developed to meet European hazardous environment specification (ATEX) for a customer that was in need of such a system in a very short time.