TECA Corp.
4048 W. Schubert
Chicago, IL 60639
T: (773) 342-4900
T: (888) 832-2872
F: (773) 342-0191
|
|
Accessories For AHP-1800XP Series Air Conditioners |
|
|
|
- DVA-1800
- Quote Request
- Picture
- Installation Drawing
- View Solid Model
|
DVA-1800
Designation: Drip Pan
Cold Side Fin Orientation: Veritical
Includes: Wicking Cord & Hose
Material:
Stainless Steel Type 304 |
Click on the image for a larger view
Click on the image for larger view
Click on the image to view DVA-1800 3D PDF file: |
|
|
|
|
|
- DHA-1800
- Quote Request
- Picture
- Installation Drawing
- View Solid Model
|
DHA-1800
Designation: Drip Pan
Cold Side Fin Orientation: Horizontal
Includes: Wicking Cord & Hose
Material:
Stainless Steel Type 304 |
Click on the image for a larger view
Click on the image for larger view
Click on the image to view DHA-1800 3D PDF file: |
|
|
|
|
|
- Fixed Point controls
- TC-1
- TC-3F
- TC-6F
- Quote Request
- Literature
|
Fixed Point Controls
TC-1C: Single set point for cooling
TC-1H: Single set point for heating
TC-6F: Three preset set points for cooling
TC-3F: Two preset set points for cooling and heating |
Model TC-1C and TC-1H power temperature controllers with its small tolerance and reset differential is the simplest and most cost effective way to control a cooling or heating device (VAC or VDC) without a need for a relay. For circuits that have higher current draw simply use them in conjunction with a solid state relay.
Model TC-6F (cool only) and TC-3F (heat/cool) thermostats are designed using two temperature power switches in conjunction with a solid state relay. For TC-6F a three position switch is provided to adjust temperature settings. |
Model TC-1C and TC-1H power temperature controllers with its small tolerance and reset differential is the simplest and most cost effective way to control a cooling or heating device (VAC or VDC) without a need for a relay. For circuits that have
higher current draw simply use them in conjunction with a solid state relay.
Part Numbers:
Mode |
Part Number |
Note |
Cool |
TC-1C-XX |
Switch closes on temperature rise |
Heat |
TC-1H-XX |
Switch closes on temperature drop |
XX: Specify temperatures 20 °C, 25 °C, 30 °C, 35 °C for cool mode and 10 °C, 15 °C for heat mode
Examples: TC-1C-20, TC-1H-10 |
Spcifications:
Voltage |
Current
(Amps) |
Set Point Tolerance
°C |
Reser Differential
°C
|
125 VAC |
2 |
+/- 3 |
3 - 6 |
250 VAC |
1.3 |
+/- 3 |
3 - 6 |
12 VDC |
2 |
+/- 3 |
3 - 6 |
24 VDC |
1.3 |
+/- 3 |
3 - 6 |
Model TC-3F (Heat/Cool) thermostat incorporates the same technology as the TC-6F. It contains a single setting each for both heating and cooling as referenced below:
Spcifications:
Model Number |
Part
Numer
|
Note |
Cool Temp. °C |
Heat Temp°C. |
Rest (MAX) °C |
Rest (TYP) °C |
Operating
Voltage |
Switching
Voltage |
Switching
Current |
TC-3F-AC |
|
VAC Version |
35 +/- 5 |
15 +/- 5 |
6.5 |
3 |
85-250 VAC |
24-280 VAC |
10 AMPS |
TC-3F-DC |
|
12/24 VDC |
35 +/-5 |
15 +/-5 |
6.5 |
3 |
3.5-32 |
0-100 VDC |
.02-20 AMPS |
Model TC-3F (Heat/Cool) thermostat incorporates the same technology as the TC-6F. It contains a single setting each for both heating and cooling as referenced below:
Spcifications:
Model Number |
Part
Numer
|
Note |
Temp @ T1 °C |
Temp @ T2 °C. |
Rest (TYP) °C |
Rest °C |
Temp @ T3 |
Operating
Voltage |
Switching
Voltage |
Switching
Current |
TC-6F |
|
No relay |
35 +/- 5 |
25 +/- 5 |
6.5 |
3 |
continuous |
N/A |
N/A |
N/A |
TC-6F-AC |
|
VAC version |
35 +/- 5 |
25 +/- 5 |
6.5 |
3 |
continuous |
85-250 VAC |
24-280 VAC |
10 AMPS |
TC-6F-DC |
|
12/24 VDC |
35 +/- 5 |
25 +/- 5 |
6.5 |
3 |
continuous |
3.5-32 VDC |
0-100 VDC |
.02 -20 AMPS |
TC-6F-DC |
|
48 VDC |
35 +/- 5 |
25 +/- 5 |
6.5 |
3 |
continuous |
3.5-32 VDC |
0-100 VDC |
.02 - 20 AMPS |
Click on the image to open the PDF file
|
|
|
|
- TC-3400
- Part Numbers
- Quote Request
- Picture
- Drawing
- Literature
|
TC-3400 PID Temperature Control
Input Voltage: 85 - 264 VAC, 12-40 VDC
Environment: -18 - 65 °C operating temprature, 0 - 90 percent RH, none-condensing
Agency /approvals: UL®/EN 61010 listed, UL® 1604 Class 1 Div 2, UL® 50 N
|
The TC-3400 temperature controller series simplifies your temperature control requirements.
The controller options reduce system complexity and the cost of control loop ownership.
The TC-3400 is a high performance PID temperature controller in space-saving, panel-mount 1/32 DIN size EIA 485 communications and standard NEMA-4X IP66 sealing make the TC-3400 versatile and suitable for wide range of environments. |
Build your own TC-3400 part number to meet your application requirments:
|
|
|
34 |
- |
X |
|
X |
|
X |
- |
X |
|
X |
- |
X |
X |
X |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input Voltage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
Universal AC - 85 to 264 VAC, 47 to 63 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
12/24 VDC - 12 to 40 VDC, 20 to 28 VAC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Functions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
Heat/Cool -No relay |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
Cool only, with relays |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
Heat/Cool, with relays |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Switching Volts & Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A |
None, drive signal only - no relays |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B |
Cool only, VAC switching, 120/240Vac, 10 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C |
Cool Only, VDC switching, 0-100 VDC, 12 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D |
Cool Only, VDC switching, 0-100 VDC, 20 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
E |
Cool Only, VDC switching, 0-100 VDC, 40 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
F |
Heat/Cool, VDC switching, 0-100 VDC, 12 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G |
Heat/Cool, VDC switching, 0-100 VDC, 20 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
H |
Heat/Cool, VDC switching, 0-100 VDC, 40 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
I |
Heat/Cool, Heat: 120/240 VAC, 10 amps Cool: VDC switching, 0-100 VDC, 12 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
J |
Heat/Cool, Heat: 120/240 VAC, 10 amps Cool: VDC switching, 0-100 VDC, 20 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K |
Heat/Cool, Heat: 120/240 VAC, 10 amps Cool: VDC switching, 0-100 VDC, 40 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
L |
Heat/Cool, Heat: 0-100 VDC, 12 Amps Cool: VAC switching, 120/240 VAC, 10 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M |
Heat/Cool, Heat: 0-100 VDC, 20 Amps Cool: VAC switching, 120/240 VAC, 10 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N |
Heat/Cool, Heat: 0-100 VDC, 40 Amps Cool: VAC switching, 120/240 VAC, 10 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
O |
Heat/Cool, Reverse Polarity, 0-100 VDC, 12 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P |
Heat/Cool, Reverse Polarity, 0-100 VDC, 20 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Q |
Heat/Cool, Reverse Polarity, 0-100 VDC, 40 Amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R |
Heat/Cool, VAC switching, 120/240 VAC, 10 amps |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sensor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
None |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
3- Wire RTD - RTD-Probe |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
T type thermocouple (ring mount) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Communications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 |
Basic communications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
RS-232 external option, same as 2 with addition of RS-232/RS-485 converter |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
RS-485 internal option, full feature communication |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Custom Features |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Click on the image for larger view
Click on the imae to open the PDF file
|
|
|
|
- Enclosure Heaters
- Part Numbers
- Quote Request
- Literature
|
Enclosure Heaters
Input Voltage: 120 VAC, 240 VAC 50/60 Hz
Power Rating: 200, 400 Watts
Mounting Style: Internal (inside enclosure)
|
TECA Enclosure heaters are the easiest and most cost effective way to add needed heat to enclosures.
These heaters come in 120 VAC and 240 VAC configurations in both 200 WATTS and 400 WATTS versions.
The integral thermostat reduces the complexity and the integral overheat safety ensures that the temperature rise is kept within safe margin. |
Click on the part numbers to request a quote
PART NUMBER |
NOTES |
POWER RATING WATTS |
INPUT VOLTAGE VAC 50/60 Hz |
CURRENT AMPS |
WEIGHT LBS. |
TEMPERATURE CONTROL °C |
OVERHEAT SAFETY °C |
EH-2001 |
single fan |
200 |
120 |
1.7 |
7 |
15 |
75 |
EH-2002 |
single fan |
200 |
240 |
0.83 |
7 |
15 |
75 |
EH-4001 |
dual fans |
400 |
240 |
3.4 |
7 |
15 |
75 |
EH-4002 |
dual fans |
400 |
240 |
1.7 |
7 |
15 |
75 |
Click on the image to open the PDF file
|
|
|
|
|
|
|
|
|
|
|
|
|
Catalog | Sizing Software | Manuals | Applications | Site Map | Privacy Policy | Testimonials | Contact