TLC-900
 

chiller

Applications:
         Bench top, laboratory, medical, laser, X-ray
  


Features:

  • Heat and cool
  • Universal 90-265 VAC input power supply
  • Compact (only 15.5" X 7.6" bench top footprint)
  • Weighs 42 lbs. (19 kg)
  • Integral PID "tunable" temperature control
  • Ambient up to +50°C
  • No compressor, fluorocarbons or filters
  • Virtually maintenance-free operation
  • Painted exterior housing
  • Low fluid level and low flow warning
  • Variable fan speed for quieter operation
  • Easy front fill design
  • RS-232 communication
  • Remote sense capability
  • Maximum operating ambient 50 °C
peltier chiller

Cooling capacity:
         310 Watts @ 0°C ΔT
         360 Watts @ 0°C ΔT (high capacity version)


Pump options:

  • Option #1 - Standard Magnetic Drive, Can Pump, 0 to 50 °C process temperature

  • Option #2 - Low Temperature Magnetic Drive, Impeller Pump, -20 to 90 °C process temperature

  • Option #3 - Gear pump, 3.75 Liter/Min, -20 to 90 °C process temperature

  • Option #4 - High FLow Magnetic Drive, Can Pump, 0 to 50 °C process temperature

Includes:

  • Integral power supply
  • Self priming pump/reservoir
  • TC-4300 temperature control
  • Low pressure drop fluid quick connects
  • Tubing and insulation

 

MODEL PART
NUMBER
CAPACITY
Watts
PUMP
OPTION
VOLTAGE
VAC
(VDC)
CURRENT
AMPS
FLUID
TEMP.
RANGE °C
MAX.
OPERATING
AMBIENT °C
Download PDF Files 3D SOLID
MODEL
QUICK
QUOTE
DRAWING PERFORMANCE
CURVE
DATA SHEET PRODUCT
MANUAL
TLC-900 6-E4EB-1-0A1 310 1 90-265 3.5 0 to 50 50    
TLC-900 6-E5EB-1-0A1 360 1 90-265 4.0 0 to 50 50    
TLC-900 6-E4EB-1-0A2 310 2 90-265 3.5 -20 to 90 50    
TLC-900 6-E5EB-1-0A2 360 2 90-265 4.0 -20 to 90 50    
TLC-900 6-E4EB-1-0A3 310 3 90-265 3.5 -20 to 90 50    
TLC-900 6-E5EB-1-0A3 360 3 90-265 4.0 -20 to 90 50    
TLC-900 6-E4EB-1-0A4 310 4 90-265 3.5 0 to 50 50    
TLC-900 6-E5EB-1-0A4 360 4 90-265 4.0 0 to 50 50    
TLC-900 6-E4E5-1-0A1 310 1 (24) 22 0 to 50 50    
TLC-900 6-E4E5-1-0A2 310 2 (24) 22 -20 to 90 50    
TLC-900 6-E4E5-1-0A3 310 3 (24) 22 -20 to 90 50    
TLC-900 6-E4E5-1-0A4 310 4 (24) 22 0 to 50 50    
 For other voltages and configurations please contact TECA.