Accessories For Temperature Controllers

Sinlg relay pack

Single Relay Pack (cool only applications)

Switching Voltage: 120/240 VAC, 0-100 VDC
Includes: Heat sink and wiring harness

Click on the part numbers to request a quick quote

PART # FUNCTION DRIVE SIGNAL SWITCHING VOLTAGE SWITCHING CURRENT
RELAY-B cool only 3-32 VDC 120/240 VAC 10 AMPS
RELAY-C cool only 3-32 VDC 0-100 VDC 12 AMPS
RELAY-D cool only 3-32 VDC 0-100 VDC 20 AMPS
RELAY-E cool only 3-32 VDC 0-100 VDC 40 AMPS
RELAY-T cool only 120 VAC 120/240 VAC 10 AMPS

Single realy pack

Click on the image to open the PDF file

Relay pack data sheet

 
Dual relay pack Dual Relay Pack (heat and cool applications)

Switching Voltage: 120/240 VAC, 0-100 VDC
Includes: Heat sink and wiring harness

Click on the part numbers to request a quick quote

PART # FUNCTION DRIVE SIGNAL SWITCHING VOLTAGE SWITCHING CURRENT
RELAY-F heat & cool 3-32 VDC 0-100 VDC 12 AMPS
RELAY-G heat & cool 3-32 VDC 0-100 VDC 20 AMPS
RELAY-H heat & cool 3-32 VDC 0-100 VDC 40 AMPS
RELAY-I heat & cool 3-32 VDC cool: 0-100 VDC heat: 120/240 VAC cool: 12 AMPS heat: 10 AMPS
RELAY-J heat & cool 3-32 VDC cool: 0-100 VDC heat: 120/240 VAC cool: 20 AMPS heat: 10 AMPS
RELAY-K heat & cool 3-32 VDC cool: 0-100 VDC heat: 120/240 VAC cool: 40 AMPS heat: 10 AMPS

RELAY-L

heat & cool 3-32 VDC cool: 120/240 VAC; heat: 0-100 VDC cool: 10 AMPS heat: 12 AMPS
RELAY-M heat & cool 3-32 VDC cool: 120/240 VAC; heat: 0-100 VDC cool: 10 AMPS heat: 20 AMPS
RELAY-N heat & cool 3-32 VDC cool: 120/240 VAC; heat: 0-100 VDC cool: 10 AMPS heat: 40 AMPS
RELAY-R heat & cool 3-32 VDC 120/240 VAC 10 AMPS
Dual relay pack dimensions

Click on the image to open the PDF file

Relay pack data sheet

 
Thermocouple Quad Relay Pack (heat/cool via reverse polarity)

Switching Voltage: 0-100 VDC
Includes: Heat sink and wiring harness

Click on the part numbers to request a quick quote

PART # FUNCTION DRIVE SIGNAL SWITCHING VOLTAGE SWITCHING CURRENT
RELAY-O heat/cool via reverse polarity 3-32 VDC 0-100 VDC 12 AMPS
RELAY-P heat & cool via reverse polarity 3-32 VDC 0-100 VDC 20 AMPS
RELAY-Q heat & cool via reverse polarity 3-32 VDC 0-100 VDC 40 AMPS

Click on the image to open the PDF file

Relay pack data sheet

 

 
RTD-Probe

RTD-Probe

Sensor Type: Three wire RTD, 100 Ω with connector
Length: 6' Minumum
Probe Size: 1/8 DIA X 6" long

Click on the image for larger view

RTD-Probe

 
RTD-Ring sensor

RTD-Ring

Sensor Type: Three wire RTD, 100 Ω with connector
Length: 6' Minumum
Mounting Style: Surface Mount

Click on the image for larger view

RTD-Ring

 
Thermocouple

Thermocouple-Ring

Sensor Type: "T" Type Thermocouple with connector
Length: 6' Minimum
Mounting Style: Surface Mount

Click on the image for larger view

T Type thermocouple

 
 
C-USB C-485/232

Function: Bi directional RS-232 to RS-485
The C-485/232 is an industrial grade (wide temperature range with surge & static protection) port-powered
bi-directional RS-232 to RS-485 converter, which can be used to convert any standard RS-232C port into a two-wire RS-485 port and vice versa.
The unit is powered from the RS-232 data line; it also supports data direction auto-turnaround. Therefore, no external power or flow control is required.

FEATURES
• Industrial grade with wide temperature range, surge and static protection.
• Port-powered, no external power or RTS, DTR required.
• Plug and play (hot-pluggable, data format auto-sensing and self-adjusting).
• Data direction auto-turnaround, no flow control is required.
• Built-in surge protection, static protection and circuit protection.
• Built-in 1201 end-of-line terminator for easy installation.
• Surface Mount Technology manufactured to ISO-9001 standards.
• CE certified.

INSTALLATION NOTES
• Connect PC’s (or other DTE device’s) COM port (or use a straight-through cable) to the RS-232 side of C-485/232, use a cross-over (Null-Modem) cable for DCE device.
• The 1201 end-of-line terminator adds heavy DC loading to a system; connect it only when the RS-485’s distance is over 660ft (200m).
• If C-485/232 is connected to any outdoor devices, please ensure that proper lightning protection is employed to prevent your devices from being damaged by lightning strikes.

C-485/232 wiring

 
C-RS232 C-RS232

Function: RS-232 M/F extension cable
Cable Length: 10 ft
Connectors: DB9 Male to DB9 Female
Note: All lines are wired straight through

 

 

 

 
   
Catalog Sizing Software | Manuals | Applications Site Map | Privacy Policy | Testimonials Contact