TECA Corp.
4048 W. Schubert
Chicago, IL 60639
T: (773) 342-4900
T: (888) 832-2872
F: (773) 342-0191
|
|
Liquid Cooled Air Conditioners
Liquid-cooled Peltier air conditioners (Peltier Coolers) use water as a coolant. A water source is necessary and
there is no air exhaust. These products can be used in indoor, outdoor and harsh environments ... read more ►
|
|
|
| |
- LHP-1700FF
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
LHP-1700FF Series
Mounting Style: Through Mounted
Voltages: 120, 240 VAC
Environments:
NEMA-12 IP40 (maintains IP 52)
* Adaptable to NEMA-4/4X & explosion proof apps.
|
Rating Traditional:
1050 BTU/hr @ 0 °F ΔT
1320 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
312 Watts L35 L35
225 Watts L35 L50
|
| * The LHP-1700FF thermoelectric air conditioner can be mounted completely inside a NEMA-4X or purged enclosure to meet the application requirements. |
Click on part number to request a quick quote
| MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC |
CURRENT AMPS. |
MIN. COOLANT FLOW GPM |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
| LHP-1700FF |
2-1090-0-000 |
Cool only |
120 |
7 |
0.3 |
None |
0/+70 |
-10/+60 |
| LHP-1700FF |
2-1080-0-000 |
Cool only |
120 |
7 |
0.3 |
TC-6F |
0/+70 |
-10/+60 |
| LHP-1700FF |
2-1050-0-000 |
Cool only |
120 |
7 |
0.3 |
EXT* |
0/+70 |
-10/+60 |
| LHP-1700FFHC |
2-1030-1-000 |
Heat/Cool |
120 |
7 |
0.3 |
TC-3F |
0/+70 |
-10/+60 |
| LHP-1700FFHC |
2-1050-1-000 |
Heat/Cool |
120 |
7 |
0.3 |
EXT* |
0/+70 |
-10/+60 |
| LHP-1702FF |
2-1092-0-000 |
Cool only |
240 |
4.7 |
0.3 |
None |
0/+70 |
-10/+60 |
| LHP-1702FF |
2-1082-0-000 |
Cool only |
240 |
4.7 |
0.3 |
TC-6F |
0/+70 |
-10/+60 |
| LHP-1702FF |
2-1052-0-000 |
Cool only |
240 |
4.7 |
0.3 |
EXT* |
0/+70 |
-10/+60 |
| LHP-1702FFHC |
2-1032-1-000 |
Heat/Cool |
240 |
4.7 |
0.3 |
TC-3F |
0/+70 |
-10/+60 |
| LHP-1702FFHC |
2-1052-1-000 |
Heat/Cool |
240 |
4.7 |
0.3 |
EXT* |
0/+70 |
-10/+60 |
EXT: Unti is set up for 5-32 VDC external signal, relay(s) included
Click on the image for a larger view

Click on the image for a larger view

Click on the image to open the PDF file

|
|
|
| |
- LHP-1200XE
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
LHP-1200XE Series
Mounting Style: Through Mounted
Voltages: 120 VAC
Environments:
NEMA-4/4X IP56
* Adaptable to explosion proof applications
|
Rating Traditional:
613 BTU/hr @ 0 °F ΔT
770 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
180 Watts L35 L35
125 Watts L35 L50
|
| * The LHP-1200XE thermoelectric air conditioner can be mounted completely inside a purged enclosure to meet the application requirements. |
Click on part number to request a quick quote.
| MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC |
CURRENT AMPS. |
MIN. COOLANT FLOW GPM |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
| LHP-1200XE |
2-3090-4-000 |
Cool only |
120 |
3.7 |
0.3 |
None |
0/+70 |
-10/+60 |
| LHP-1200XE |
2-3080-4-000 |
Cool only |
120 |
3.7 |
0.3 |
TC-6F |
0/+70 |
-10/+60 |
| LHP-1200XE |
2-30F0-4-000 |
Cool only |
120 |
3.7 |
0.3 |
85°F (30°) |
0/+70 |
-10/+60 |
| LHP-1200XE |
2-3050-4-000 |
Cool only |
120 |
3.7 |
0.3 |
EXT* |
0/+70 |
-10/+60 |
| LHP-1200XEHC |
2-3030-5-000 |
Heat/Cool |
120 |
3.7 |
0.3 |
TC-3F |
0/+70 |
-10/+60 |
| LHP-1200XEHC |
2-3050-5-000 |
Heat/Cool |
120 |
3.7 |
0.3 |
EXT* |
0/+70 |
-10/+60 |
EXT: Unti is set up for 5-32 VDC external signal, relay(s) included
Click on the image for a larger view

Click on the image for larger view of the performance curve
 |
Click on the image for a larger view

View or request 3D solid model files for this product:
Click on the image to open the PDF file

|
|
|
| |
- LHP-1200XP
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
LHP-1200XP Series
Mounting Style: Through Mounted
Voltage: 120 VAC
Environments:
Class 1 Div 2,
NEMA-4/4X IP56
Class 1 Div 1, ATEX Zone 1 |
Rating Traditional:
613 BTU/hr @ 0 °F ΔT
770 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
180 Watts L35 L35
125 Watts L35 L50
|
|
Click on part number to request a quick quote
|
MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC |
CURRENT AMPS. |
MIN. COOLANT FLOW GPM |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
C
I
D
2 |
LHP-1200XP † |
2-3090-2-027 |
Cool only |
120 |
3.7 |
0.3 |
None |
0/+71 |
-10/+50 |
| LHP-1200XP † |
2-3080-2-028 |
Cool only |
120 |
3.7 |
0.3 |
TC-6F |
0/+71 |
-10/+50 |
| LHP-1200XP † |
2-30F0-2-029 |
Cool only |
120 |
3.7 |
0.3 |
85°F (30°) |
0/+71 |
-10/+50 |
| LHP-1200XP † |
2-3050-2-030 |
Cool only |
120 |
3.7 |
0.3 |
SSR drive |
0/+71 |
-10/+50 |
| LHP-1200XPHC † |
2-3030-3-031 |
Heat/Cool |
120 |
3.7 |
0.3 |
TC-3F |
0/+71 |
-10/+50 |
| LHP-1200XPHC † |
2-3050-3-032 |
Heat/Cool |
120 |
3.7 |
0.3 |
SSR drive |
0/+71 |
-10/+50 |
C
I
D
1 |
LHP-1200XP † |
2-3090-2-021 |
Cool only |
120 |
3.7 |
0.3 |
none |
0/+50 |
-10/+50 |
| LHP-1200XP † |
2-3080-2-022 |
Cool only |
120 |
3.7 |
0.3 |
TC-6F |
0/+50 |
-10/+50 |
| LHP-1200XP † |
2-30F0-2-023 |
Cool only |
120 |
3.7 |
0.3 |
85°F (30°) |
0/+50 |
-10/+50 |
| LHP-1200XP † |
2-3050-2-024 |
Cool only |
120 |
3.7 |
0.3 |
SSR drive |
0/+50 |
-10/+50 |
| LHP-1200XPHC † |
2-3030-3-025 |
Heat/Cool |
120 |
3.7 |
0.3 |
TC-3F |
0/+50 |
-10/+50 |
| LHP-1200XPHC † |
2-3050-3-026 |
Heat/Cool |
120 |
3.7 |
0.3 |
SSR drive |
0/+50 |
-10/+50 |
Agency approvals pending; ATEX certification will require full system approval.
All specifications subject to change without notice.
Click on the image for a larger view

Click on the image for larger view of the performance curve

|
Click on the image for a larger view

View or request 3D solid model files for this product:
Click on the image to open the PDF file

|
|
| |
| |
- LHP-800FF
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
LHP-800FF Series
Mounting Style: Internal Mounted
Voltages: 24 VDC
Environments:
NEMA-12 IP40
* Adaptable to NEMA-4/4X & explosion proof apps.
|
Rating Traditional:
500 BTU/hr @ 0 °F ΔT
615 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
146 Watts L35 L35
105 Watts L35 L50
|
| * The LHP-800FF thermoelectric air conditioner can be mounted completely inside a NEMA-4X or purged enclosure to meet the application requirements. |
Click on part number to request a quick quote
| MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VDC |
CURRENT AMPS. |
MIN. COOLANT FLOW GPM |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
| LHP-800FF |
2-5095-0-000 |
Cool only |
24 |
14 |
0.3 |
0/+70 |
-10/+60 |
| LHP-800FFHC |
2-5099-1-000 |
Heat/Cool |
24 |
14 |
0.3 |
0/+70 |
-10/+60 |
Note: No provision for temperature control is included. Consult factory for options.
Click on the image for a larger view

Click on the image for a larger view

Click on the imge to open the PDF file

|
|
|
| |
- LHP-300FF
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
LHP-300FF Series
Mounting Style: Internal Mounted
Voltages: 24 VDC
Environments:
NEMA-12 IP40
* Adaptable to NEMA-4/4X & explosion proof apps.
|
Rating Traditional:
160 BTU/hr @ 0 °F ΔT
200 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
48 Watts L35 L35
34 Watts L35 L50
|
| * The LHP-300FF thermoelectric air conditioner can be mounted completely inside a NEMA-4X or purged enclosure to meet the application requirements. |
Click on part number to request a quick quote
MODEL NUMBER
|
PART NUMBER |
FUNCTION |
VOLTAGE VDC |
Current
AMPS. |
COOLANT FLOW MIN. GPM |
Ambient
RANGE
°C |
| LHP-300FF |
2-7098-0-000 |
Cool only |
12/24 |
12/6 |
0.3 |
0/70 |
| LHP-300FFHC |
2-7095-1-000 |
Heat/Cool |
24 |
6 |
0.3 |
0/70 |
Note: No provision for temperature control is included. Consult TECA for options.
Click on the image for a larger view

Click for larger view of the performance curve |
Click on the image for a larger view
Click on the image to open the PDF file

|
|
| |
| |
TECA offers a variety of liquid-cooled thermoelectric air conditioners (Peltier coolers). A water source is necessary. The water acts as a coolant, carrying heat away. There is no air exhaust on the hot side of the air conditioner. The liquid-cooled Peltier coolers (thermoelectric) air conditioners on this page are extremely versatile. They work well in tight enclosures and are rated for NEMA-12, NEMA-4X, Class 1 Division 2 and Class 1 Division 1. The LHP-1700FF Model solid-state (thermoelectric) air conditioner can even be mounted completely inside a purged enclosure.
Performance ratings range from 160 BTU/hr to 1,050 BTU/hr, which represents our largest liquid cooled thermoelectric panel cooler. Applications include equipment racks, PCs, drives, amplifiers, motor controls and other electronic equipment. The solid-state construction is the perfect low-maintenance solution for hard-to-access areas. There are no filters to change and no moving parts except for the cold side (inside) fan. Our Peltier coolers use robust thermoelectric modules and boast a long service life.
|
|
| |
| |
|
|
| |
|
|
| |
Catalog | Sizing Software | Manuals | Applications | Site Map | Privacy Policy | Testimonials | Contact
© 2010 Thermoelectric Cooling America Corporation. All Rights Reserved.
|
|
|