TECA Corp.
4048 W. Schubert
Chicago, IL 60639
T: (773) 342-4900
T: (888) 832-2872
F: (773) 342-0191
|
|
Flush Mounted Indoor Air Conditioners
The air conditioners on this page are flush-mounted and intended for NEMA-12enclosures.
The solid-state construction is a perfect low-maintenancesolution: no filtersto change and
no moving parts except for the fans ... read more ►
|
|
|
| |
- FHP-2850
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
FHP-2850 Series
Mounting Style: Flush Mounted
Voltages: 120 VAC, 240 VAC
Environments:
NEMA-12 IP40 (maintains IP 52)
|
Rating Traditional:
1700 BTU/hr @ 0 °F ΔT
2200 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
500 Watts L35 L35
325 Watts L35 L50
|
| |
Click on part number to request a quick quote
| MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC |
Current AMPS. |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
| FHP-2850 |
7-D580-0-000 |
Cool only |
120 |
12.5 |
TC-6F |
-15/+70 |
-10/+60 |
| FHP-2850 |
7-D550-0-000 |
Cool only |
120 |
12.5 |
EXT |
-15/+70 |
-10/+60 |
| FHP-2852 |
7-D582-0-000 |
Cool only |
240 |
7.5 |
TC-6F |
-15/+70 |
-10/+60 |
| FHP-2852 |
7-D552-0-000 |
Cool only |
240 |
7.5 |
EXT |
-15/+70 |
-10/+60 |
EXT: Unti is set up for 5-32 VDC external signal, relay(s) included
Click on the image for a larger view

Click for larger view of the performance curve

|
Other test curves for FHP-2850 which might be of interest:
- FHP-2852 248 VAC 30 C amb
|
Click on the image for a larger view

Click on the image to open the PDF file

|
|
|
| |
- FHP-1501
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
FHP-1501 Series
Mounting Style: Flush Mounted
Voltage: 120/240 VAC, 24 VDC
Environments:
NEMA-12 IP40 (maintains IP 52)
UL-1995/CSA 22.2, CE
ETL; TÜV
|
Rating Traditional:
950 BTU/hr @ 0 °F ΔT
1270 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
278 Watts L35 L35
162 Watts L35 L50
|
| |
NEMA-4 (outdoors) versions |
Click on part number to request a quick quote
| MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC (VDC) |
Current AMPS. |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
APPROVALS (NRTL) |
| FHP-1501 |
7-2181-0-000 |
Cool only |
120/240 |
8.0/5.5 |
TC-6F† |
-40/+65 |
-10/+60 |
Yes |
| FHP-1501 |
7-2151-0-000 |
Cool only |
120/240 |
8.0/5.5 |
EXT |
-40/+65 |
-10/+60 |
Yes |
| FHP-1501 |
7-21F1-0-000 |
Cool only |
120/240 |
8.0/5.5 |
85°F (30°C) |
-40/+65 |
-10/+60 |
Yes |
| FHP-1501HC |
7-2131-1-000 |
Heat/Cool |
120/240 |
8.0/5.5 |
TC-3F |
-40/+65 |
-10/+60 |
Yes |
| FHP-1501HC |
7-2151-1-000 |
Heat/Cool |
120/240 |
8.0/5.5 |
EXT |
-40/+65 |
-10/+60 |
Yes |
| FHP-1501 |
7-2185-0-000 |
Cool only |
(24) |
18 |
TC-6F |
-40/+70 |
-10/+60 |
No |
| FHP-1501 |
7-2155-0-000 |
Cool only |
(24) |
18 |
EXT |
-40/+70 |
-10/+60 |
No |
| FHP-1501 |
7-21F5-0-000 |
Cool only |
(24) |
18 |
85°F (30°C) |
-40/+70 |
-10/+60 |
No |
| FHP-1501HC |
7-2135-1-000 |
Heat/Cool |
(24) |
18 |
TC-3F |
-40/+70 |
-10/+60 |
No |
| FHP-1501HC |
7-21I5-1-000 |
Heat/Cool |
(24) |
18 |
TC-7F |
-40/+70 |
-10/+60 |
No |
| FHP-1501HC |
7-2155-1-000 |
Heat/Cool |
(24) |
18 |
EXT |
-40/+70 |
-10/+60 |
No |
| FHP-1501HC |
7-21H5-1-000 |
Heat/Cool |
(24) |
18 |
TC-4600 |
-40/+70 |
-10/+60 |
No |
EXT: Unti is set up for 5-32 VDC external signal, relay(s) included
† Unti evaluated by ETL
Click on the image for a larger view

Click on the image for a larger view

View or request 3D solid model files for this product:
Click on the image to open the PDF file

|
|
|
| |
- FHP-750
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
FHP-750 Series
Mounting Style: Flush Mounted
Voltage: 120, 240 VAC, 24 VDC
Environments:
NEMA-12 IP40 (maintains IP 52)
UL-1995/CSA 22.2, CE
ETL; TÜV
|
Rating Traditional:
430 BTU/hr @ 0 °F ΔT
560 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
125 Watts L35 L35
78 Watts L35 L50
|
| |
NEMA-4 (outdoors) versions |
Click on part number to request a quick quote
| MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC (VDC) |
Current AMPS. |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
APPROVALS (NRTL) |
| FHP-750 |
7-A580-0-000 |
Cool only |
120 |
4 |
TC-6F |
-15/+65 |
-10/+60 |
Yes |
| FHP-750 |
7-A550-0-000 |
Cool only |
120 |
4 |
EXT |
-15/+65 |
-10/+60 |
Yes |
| FHP-750 |
7-A5F0-0-000 |
Cool only |
120 |
4 |
85°F (30°C) |
-15/+65 |
-10/+60 |
Yes |
| FHP-752 |
7-A582-0-000 |
Cool only |
240 |
2.5 |
TC-6F |
-15/+65 |
-10/+60 |
Yes |
| FHP-752 |
7-A552-0-000 |
Cool only |
240 |
2.5 |
EXT |
-15/+65 |
-10/+60 |
Yes |
| FHP-752 |
7-A5F2-0-000 |
Cool only |
240 |
2.5 |
85°F (30°C) |
-15/+65 |
-10/+60 |
Yes |
| FHP-750 |
7-A585-0-000 |
Cool only |
(24) |
9 |
TC-6F |
-40/+70 |
-10/+60 |
No |
| FHP-750 |
7-A555-0-000 |
Cool only |
(24) |
9 |
EXT |
-40/+70 |
-10/+60 |
No |
| FHP-750 |
7-A5F5-0-000 |
Cool only |
(24) |
9 |
85°F (30°C) |
-40/+70 |
-10/+60 |
No |
| FHP-750HC |
7-A5I5-1-000 |
Heat/Cool Rev. Pol. |
(24) |
9 |
TC-7F |
-40/+70 |
-10/+60 |
No |
| FHP-750HC |
7-A595-1-000 |
Heat/Cool Rev. Pol. |
(24) |
9 |
EXT |
-20/+70 |
-10/+60 |
No |
EXT: Unti is set up for 5-32 VDC external signal, relay(s) included
Click on the image for a larger view

Click on the image for a larger view

View or request 3D solid model files for this product:
Click on the image to open the PDF file

|
|
| |
| |
- FHP-500
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
FHP-500 Series
Mounting Style: Flush Mounted
Voltages: 24 VDC
Environments:
NEMA-12 IP40 (maintains IP 52)
|
Rating Traditional:
251 & 416 BTU/hr @ 0 °F ΔT
372 & 536 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
75 & 124 Watts L35 L35
27 & 68 Watts L35 L50
|
| |
NEMA-4 (outdoors) versions
|
Click on part number to request a quick quote
| MODEL NUMBER |
PART NUMBER |
FUNCTION |
COP @ 0 °C ∆T L35 L35 |
VOLTAGE VDC |
Current AMPS. |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
| FHP-570 |
7-G0F5-0-000 |
Cool Only |
1 |
24 |
3 |
85°F (30°C) |
-10/+70 |
-10/+60 |
| FHP-570HC |
7-G095-1-000 |
Heat/Cool † |
1 |
24 |
3 |
None* |
-10/+70 |
-10/+60 |
| FHP-570HC |
7-G0I5-1-000 |
Heat/Cool |
1 |
24 |
3 |
TC-7F |
-10/+70 |
-10/+60 |
| FHP-590 |
7-G0F5-0-001 |
Cool Only |
0.72 |
24 |
6.9 |
85°F (30°C) |
-10/+70 |
-10/+60 |
| FHP-590HC |
7-G095-1-001 |
Heat/Cool † |
0.72 |
24 |
6.9 |
None* |
-10/+70 |
-10/+60 |
| FHP-590HC |
7-G0I5-1-001 |
Heat/Cool |
0.72 |
24 |
6.9 |
TC-7F |
-10/+70 |
-10/+60 |
* For controller options contact TECA
† Heating function via reverse polarity (controller dependent)
Click on the image for a larger view

Click for larger view of the performance curve

|
Other test curves for FHP-590/570 which might be of interest:
|
Click on the image for a larger view

Click on the imge to open the PDF file

|
|
|
| |
- FHP-401
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
FHP-401 Series
Mounting Style: Flus Mounted
Voltages: 120, 240 VAC
Environments:
NEMA-12 IP40 (maintains IP 52)
|
Rating Traditional:
302 BTU/hr @ 0 °F ΔT
447 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
91 Watts L35 L35
38 Watts L35 L50
|
| |
Click on part number to request a quick quote
| MODEL NUMBER |
PART NUMBER |
FUNCTION |
VOLTAGE VAC |
Current AMPS. |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
| FHP-401 |
7-F090-0-000 |
Cool only |
120 |
1.3 |
None |
-10/+70 |
-10/+60 |
| FHP-401 |
7-F080-0-000 |
Cool only |
120 |
1.3 |
TC-6F |
-40/+70 |
-10/+60 |
| FHP-401 |
7-F0F0-0-000 |
Cool only |
120 |
1.3 |
85°F (30°C) |
-40/+70 |
-10/+60 |
| FHP-401 |
7-F050-0-000 |
Cool only |
120 |
1.3 |
EXT |
-40/+70 |
-10/+60 |
| FHP-401HC |
7-F0I0-1-000 |
Heat/Cool |
120 |
1.3 |
TC-7F |
-40/+70 |
-10/+60 |
| FHP-402 |
7-F092-0-000 |
Cool only |
240 |
0.7 |
None |
-10/+70 |
-10/+60 |
| FHP-402 |
7-F082-0-000 |
Cool only |
120 |
0.7 |
TC-6F |
-40/+70 |
-10/+60 |
| FHP-402 |
7-F0F2-0-000 |
Cool only |
120 |
0.7 |
85°F (30°C) |
-40/+70 |
-10/+60 |
| FHP-402 |
7-F052-0-000 |
Cool only |
120 |
0.7 |
EXT |
-40/+70 |
-10/+60 |
| FHP-402HC |
7-F0I2-1-000 |
Heat/Cool |
120 |
0.7 |
TC-7F |
-40/+70 |
-10/+60 |
EXT: Unti is set up for 5-32 VDC external signal, relay(s) included
Click on the image for a larger view

Click for larger view of the performance curve

|
Other test curves for FHP-401 which might be of interest:
|
Click on the image for a larger view

Click on the imge to open the PDF file

|
|
| |
| |
- FHP-400
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
FHP-400 Series
Mounting Style: Through Mounted
Voltages: 24 VDC
Environments:
NEMA-12 IP40 (maintains IP 52)
|
Rating Traditional:
179 & 259 BTU/hr @ 0 °F ΔT
280 & 360 BTU/hr @ +20 °F ΔT
Rating DIN 3168:
55 & 80 Watts L35 L35
15 & 40 Watts L35 L50
|
| |
NEMA-4 (outdoors) versions |
Click on part number to request a quick quote
| MODEL NUMBER |
PART NUMBER |
FUNCTION |
COP @ 0 °C ∆T L35 L35 |
VOLTAGE VDC |
Current AMPS. |
CONTROL |
AMBIENT RANGE °C |
ENCLOSURE RANGE °C |
| FHP-450 |
7-F0F5-0-000 |
Cool Only |
0.99 |
24 |
2.3 |
85°F (30°C) |
-10/+70 |
-10/+60 |
| FHP-450HC |
7-F095-1-000 |
Heat/Cool † |
0.99 |
24 |
2.3 |
None* |
-10/+70 |
-10/+60 |
| FHP-450HC |
7-F0I5-1-000 |
Heat/Cool |
0.99 |
24 |
2.3 |
TC-7F |
-10/+70 |
-10/+60 |
| FHP-470 |
7-F0F5-0-001 |
Cool Only |
0.48 |
24 |
7 |
85°F (30°C) |
-10/+70 |
-10/+60 |
| FHP-470HC |
7-F095-1-001 |
Heat/Cool † |
0.48 |
24 |
7 |
None* |
-10/+70 |
-10/+60 |
| FHP-470HC |
7-F0I5-1-001 |
Heat/Cool |
0.48 |
24 |
7 |
TC-7F |
-10/+70 |
-10/+60 |
* For controller options contact TECA
† Heating function via reverse polarity (controller dependent)
Click on the image for a larger view

Click for larger view of the performance curve

|
Other test curves for FHP-450/470 which might be of interest:
|
Click on the image for a larger view

Click on the imge to open the PDF file

|
|
| |
| |
The indoor-use (for cooling NEMA-12 enclosures) thermoelectric air conditioners (Peltier coolers) on this page are all flush-mounted. The air conditioner will not intrude into your enclosure at all. This is ideal when internal cabinet space is sparse. Mounting gasket and hardware are always included.
All "FHP" (flush-mounted) models conveniently feature an internal condensate removal system. Thermoelectric cooling (Peltier cooling) capacity of these enclosure coolers ranges from the FHP-750 model which offers 430 BTU/hr to the FHP-2850 model which offers 1700 BTU/hr. The FHP-2850 is the largest Peltier cooler (thermoelectric cooler) we offer and it is available for 120 or 240 VAC input. Also of note is our FHP-1501 model. This thermoelectric air conditioner (electronic enclosure cooling) features dual-voltage (120/240 VAC) capability. All the Peltier coolers on this page can be installed in multiple units for incremental cooling capacity. 24 vdc configurations are available.
Our Peltier air conditioners (Peltier coolers) are often used to cool small enclosures such as control panels, kiosks, ATMs, crane controls, electronics enclosures, display signs and more.
The solid-state construction is the perfect low-maintenance solution for hard-to-access areas. There are no filters to change and no moving parts except for the fans. Our Peltier coolers use robust thermoelectric modules and boast a long service life.
|
|
| |
|
|
| |
Catalog | Sizing Software | Manuals | Applications | Site Map | Privacy Policy | Testimonials | Contact
© 2010 Thermoelectric Cooling America Corporation. All Rights Reserved.
|
|
|