Air Cooled Bench Top Thermoelectric Liquid Chillers
Bench top Recirculating Liquid Chillers are a compact and reliable solution for cooling and heating water and glycol/water solutions.
Suitable for laboratory and portable applications, many accessories, options and custom modifications are available... read more

through flow liquid chiller

TFC-2700 Series
Through Flow Liquid Chiller

Style: Wheeled Mobile Platform
Voltages: 100 - 240 VAC
Environments: Laboratory, Industrial

Cooling capacity:
830 Watts @ 0 °C ΔT (fluid out - ambient)
Includes:
Integral Power Supply
Temperature control (TC-3400)
Low pressure drop shut off fittings

Click on part number to request a quick quote

MODEL NUMBER PART NUMBER VOLTAGE VAC POWER WATTS WEIGHT LBS. (KG) OPERATING TEMP °C TEMP. CONTROL FLUID TEMP RANGE °C
TFC-2700 6-N0GB-1-0A0 100 - 240 1000 115 (52) 0 - 50 TC-3400 0 - 50
TFC-2700 6-N0GB-1-0A1* 100 - 240 1000 115 (52) 0 - 50 TC-3400 0 - 50

* TFC-2700 thermoelectric liquid chiller with dual speed fan option

Features:

• Integral PID “tunable” temperature control
• No pump, no reservoir, insert directly into your flow
• Through flow temperature controlled cooling and heating
• Always cold/warm, never freeze/boil for intermittent flows
• No compressor, fluorocarbons or filters
• Virtually maintenance-free operation
• Mobile platform on locking wheels
• Integral power supply for 100-240 VAC operation
• Painted stainless steel exterior
• Front to back air flow
• No Compressor, fluorocarbons or filters
• Virtually maintenance free operation

Click on the image for a larger view

mobile chiller

Click on the image for a larger view of the curves

mobile chiller


 

Peltier cooler

Click on the image for a larger view

TE chiller


TE chiller

View or request 3D solid model files for this product:

Click on the image to view TFC-2700 3D PDF file: water chiller

Click on the image to open the PDF file

laboratory chiller

 
thermoelectric liquid chiller

TLC-1400 Series
Recirculating Liquid Chiller

Style: Bench Top
Voltages: 120 VAC, 240 VAC
Environments: Bench Top, Laboratory, Industrial

Cooling capacity:
410 Watts @ 0 °C ΔT
Includes:
Pump and reservoir
Integral Power Supply
Temperature control (TC-3400)
RS-232 Communications (optional)
Remote Sensibility (optional)

Click on part number to request a quick quote

MODEL NUMBER PART NUMBER VOLTAGE VAC CURRENT AMPS. WEIGHT LBS. (KG) MAX OPERATING TEMP °C TEMP. CONTROL HEATING OPTION (HC SUFFIX) Watts FLUID TEMP RANGE °C
TLC-1400 6-B0G0-0-000 120 VAC 7 59(26.7) 50 °C(+122 F) TC-3400
-5/65
TLC-1400HC 6-B0G0-1-000 120 VAC 7 59(26.7) 50 °C(+122 F) TC-3400 400 Watt -5/65
TLC-1402 6-B0G2-0-000 240 VAC 4 59(26.7) 50 °C(+122 F) TC-3400
-5/65
TLC-1402HC 6-B0G2-1-000 240 VAC 4 59(26.7) 50 °C(+122 F) TC-3400 400 Watt -5/65

Features:
• Compact (only 12" X 14" bench top footprint)
• Weighs approximately 59 lbs. (27 kg)
• Integral PID "tunable" temperature control (two styles)
• Ambient temperature up to +50°C
• No compressor, fluorocarbons or filters
• Virtually maintenance-free operation
• Remote Sensibility™
• Un-cooled, 500mL reservoir
• Front to back air-flow system
• Stainless steel exterior housing
• Low fluid level and low flow warning
• Integral power supply
• Self priming pump/reservoir
• Low pressure drop fluid quick connects
• Tubing and insulation
• 3/8" CPC low pressure drop shut off fit

Click on the image for a larger view

peltier liquid chiller

Click on the image for a larger view of the performance curve

recirculating liquid chiller


Other test curves for TLC-1400 which might be of interest:

  1. Cooling Plas Lab glove box using a TLC-1400 liquid chiller and a Radiator (fan coil)

Click on the image for a larger view of the flow vs pressure curve

recirculating chiller

Click on the image for a larger view

liquid chiller

View or request 3D solid model files for this product:

Click on the image to view TLC-1400 3D PDF file: peltier coolers

Click on the image to open the PDF file

laboratory chiller

 
laboratory chillers

TLC-900 Series
Recirculating Liquid Chiller

Style: Bench Top
Voltages: 100-240 VAC, 24 VDC
Environments: Bench Top, Laboratory, Industrial

Cooling capacity:
350 Watts @ 0 °C ΔT
310 Watts @ 0 °C ΔT (24 VDC configuration)
Includes:
Pump and reservoir
Integral Power Supply
Integral PWM Temperature control
USB Communications
Remote Sensibility

Click on part number to request a quick quote

MODEL NUMBER PART NUMBER PUMP OPTION VOLTAGE VAC (VDC) CURRENT AMPS MAX. OPERATING TEMP. °C FLUID TEMP. RANGE °C
TLC-900 6-E5KB-1-0A1 1 100-240 4 50 °C (+122 F) 0 to 50
TLC-900 6-E5KB-1-0A2 2 100-240 4 50 °C (+122 F) -20 to 90
TLC-900 6-E5KB-1-0A3 3 100-240 4 50 °C (+122 F) -20 to 90
TLC-900 6-E5KB-1-0A4 4 100-240 4 50 °C (+122 F) 0 to 50
TLC-900 6-E4K5-1-0A1 1 (24) 22 50 °C (+122 F) 0 to 50
TLC-900 6-E4K5-1-0A2 2 (24) 22 50 °C (+122 F) -20 to 90
TLC-900 6-E4K5-1-0A3 3 (24) 22 50 °C (+122 F) -20 to 90
TLC-900 6-E4K5-1-0A4 4 (24) 22 50 °C (+122 F) 0 to 50

Pump Options:
• Option #1 - Standard Magnetic Drive, Can Pump,
0 to 50 °C process temperature

• Option #2 - Low Temperature Magnetic Drive, Impeller Pump, -20 to 90 °C process temperature

• Option #3 - Gear pump, 3.75 Liter/Min, -20 to 90 °C process temperature

• Option #4 - High Flow Magnetic Drive, Can Pump,
0 to 50 °C process temperature

Control Features:
•Integral "tunable" PWM temperature control
•Bi-directional Temperature Control for Thermoelectric applications
•4 Temperature zone with 4 independent PID settings
•Heating and Cooling
•Internal RTD sensor
•Remote Sensibility™ switchable exterior sensor
•Output PWM 1KHz, duty cycle resolution=1000 steps
•Labview VI examples available
•USB communications

Click on the image for a larger view

TEC chiller

Click on the image for larger view of the performance curve

lab chiller

Other test curves for TLC-900 which might be of interest:

  1. Cascade system using TLC-900 and LHP-150CP
  2. Cooling glove box using TLC-900 and FC10-01 fan coill
  3. Control test of glove box cooled with TLC-900 and FC10-01 fan coil

Click on the image for larger view of the pump curve

laboratory liquid chiller

Click on the image for a larger view

laboratory peltier chiller

 

View or request 3D solid model files for this product:

Click on the image to view TLC-900 3D PDF file: industrial liquid chiller

Click on the image to open the PDF file

industrial chiller

 
laboratory chiller

TLC-1200 Series
Style: Bench Top and wall mount
Voltages: 24 VDC
Environments: Bench Top, Laboratory, Industrial

Cooling capacity:
215 Watts @ 0 °C ΔT
Includes:
3/8" OD stainless steel tubing
Integral H-Bridge for heat/cool operation
Two separate flow paths

Rubber feet
Power input leads

Click on part number to request a quick quote

MODEL NUMBER PART NUMBER VOLTAGE VDC CURRENT AMPS HEATING OPTION CONTROL OPTION MAX. OPERATING TEMP. FLUID TEMP. RANGE
TLC-1200 6-3095-0-000 24 9 Cool Only None 50 °C(+122 F) -5/65
TLC-1200 6-3055-0-000 24 9 Cool Only EXT* 50 °C(+122 F) -5/65
TLC-1200HC 6-3055-1-000 24 9 Heat/Cool EXT** 50 °C(+122 F) -5/65

Click on the image for a larger view

OEM liquid chillers

Click on the image for larger view
TLC-1200 performance curve TEC liquid chiller

Click on the image for a larger view

peltier liquid chiller

View or request 3D solid model files for this product:

Click on the image to view TLC-1200 3D PDF file: thermoelectric liquid chiller

Click on the image to open the PDF file

industrial liquid chiller

 
industrial liquid chiller

TLC-700 Liquid Chiller
Recirculating Liquid Chiller
Style: Bench Top
Voltages: 120 VAC, 240 VAc, 24 VDC
Environments: Bench Top, Laboratory, Industrial

Cooling capacity:
215 Watts @ 0 °C ΔT
Includes:
Pump and reservoir
Integral Power Supply
Integral Temperature control (TC-3300)
RS-232 Communications (optional)
Remote Sensibility (optional)

Click on part number to request a quick quote

MODEL NUMBER PART NUMBER VOLTAGE VAC CURRENT AMPS WEIGHT LB (KG) MAX. OPERATING TEMP. °C (°F)

HEATING OPTION WATTS

TEMP. CONTROL FLUID TEMP. RANG °C APPROVALS (NRTL)
TLC-700 6-A0D0-0-000 120 4.2 32(14.5) 50 (122)
TC-3300 -5/65 UL3101-1 CSA22.2, CE
TLC-700HC 6-A0D0-1-000 120 4.2 32(14.5) 50 (122 ) 200 TC-3300 -5/65 UL3101-1 CSA22.2, CE
TLC-702 6-A0D2-0-000 240 2.9 42(19) 50 (122 )
TC-3300 -5/65 UL3101-1 CSA22.2, CE
TLC-702HC 6-A0D2-1-000 240 2.9 42(19) 50 (122 ) 200 TC-3300 -5/65 UL3101-1 CSA22.2, CE

Features:
• Compact (only 15.5" X 7.6" bench top footprint)
• Weighs approximately 32 lbs. (14.5 kg)
• Integral PID "tunable" temperature control (two styles)
• Ambient temperature up to +50°C
• No compressor, fluorocarbons or filters
• Virtually maintenance-free operation
• Remote Sensibility™
• Un-cooled, 500mL reservoir
• Front to back air-flow system
• Stainless steel exterior housing
• Low fluid level and low flow warning
• Integral power supply
• Self priming pump/reservoir
• Low pressure drop fluid quick connects
• Tubing and insulation
• 3/8" CPC low pressure drop shut off fittings

Click on the image for a larger view

industrial chillerslaboratory chillers

Click for larger view of the performance curve

liquid chiller

Other test curves for TLC-700 which might be of interest:

  1. Cooling 100 watts load plate using TLC-700 (temperature vs time)
  2. Cooling load plate with no active load using TLC-700 (temperature vs time)

Click for larger view of the pump curve

liquid chillers

Click on the image for a larger view

liquid cooler

 View or request 3D solid model files for this product:

Click on the image to view TLC-700 3D PDF file: laboratory chiller
Click on the image to view TLC-702 3D PDF file: laboratory chillers

Click on the image to open the PDF file

lab chillers

 
OEM liquid chillers

TLC Peltier Cooling Cubes
Description: Liquid chiller core
Voltages: Various DC inputs available
Requirement: Pump, Power Supply, Tubing, Fan and Housing

Notes:
TECA
model TLC³ cooling cubes are thermoelectric cooling “engines” that the engineer or designer can use in OEM systems.
Generally these are made in 100, 200 and 300 Watts capacity range, they work with a variety of fans.
Small or large quantities available.

Click on the image for a larger view

OEM liquid chillers

Click for larger view of the curves

peltier fluid coolers peltier liquid cooler

Click on the image for a larger view

industrial OEM chillers

 View or request 3D solid model files for this product:

Click on the image to view small TLC Cube 3D PDF file: Small TLC Cube solid model
Click on the image to view medium TLC Cube 3D PDF file: Medium TLC Cube solid model
Click on the image to view large TLC Cube 3D PDF file: LArge TLC Cube solid model

Click on the image to open the PDF file

TLC Cube cooling cores

 

 

TECA's solid-state Recirculating Liquid Chillers for bench top use offer versatility, reliability and performance. Applications include quality control, sample heating and cooling, laboratory testing, laser cooling, manufacturing and more. Notably, the TLC-900 has been used in published research (see 50 Years of Innovation section on this website for details, 2012).

Versatility: Various input voltages are available for each model. Most models include an integral, programmable temperature controller. Heating is an available option on all models. Accessories are available including fittings and low-temperature cold plate attachments (cascades). The TLC3 solid-state Cooling Cubes provide a thermoelectric cooling "engine" around which you can build your own system. The TLC-1200 offers two separate cooling circuits.

Reliability: The solid-state (Peltier) construction is the perfect low-maintenance solution. There are no filters to change and no moving parts except for the fans. Our Peltier coolers use robust thermoelectric modules and boast a long service life.

Performance: Low-temperature cold plate (cascade) attachments can reach temperatures as low as -50C. Multiple features including RS-232 communications and data-logging software is included with the TLC-900 model.

 
   
Catalog Sizing Software | Manuals | Applications Site Map | Privacy Policy | Testimonials Contact
© 2014 ThermoElectric Cooling America Corporation. All Rights Reserved.