TLC-1400 Series
Recirculating Liquid Chiller
Style: Bench Top
Voltages: 120 VAC, 240 VAC
Environments:
Bench Top
Laboratory
Industrial
|
Cooling capacity:
410 Watts @ 0 °C
ΔT
Includes:
Pump and reservoir
Integral Power Supply
Temperature control (TC-3400)
RS-232 Communications (optional)
Remote Sensibility (optional)
|
Click on part number to request a quick quote
| MODEL |
PART NUMBER |
VOLTAGE VAC |
CURRENT AMPS. |
WEIGHT LBS. (KG) |
MAX OPERATING TEMP °C |
TEMP. CONTROL |
HEATING OPTION (HC SUFFIX) Watts |
FLUID TEMP RANGE °C |
| TLC-1400 |
6-B0G0-0-000 |
120 VAC |
7 |
59(26.7) |
50 °C(+122 F) |
TC-3400 |
|
-5/65 |
| TLC-1400HC |
6-B0G0-1-000 |
120 VAC |
7 |
59(26.7) |
50 °C(+122 F) |
TC-3400 |
400 Watt |
-5/65 |
| TLC-1402 |
6-B0G2-0-000 |
240 VAC |
4 |
59(26.7) |
50 °C(+122 F) |
TC-3400 |
|
-5/65 |
| TLC-1402HC |
6-B0G2-1-000 |
240 VAC |
4 |
59(26.7) |
50 °C(+122 F) |
TC-3400 |
400 Watt |
-5/65 |
Features:
• Compact (only 12" X 14" bench top footprint)
• Weighs approximately 59 lbs. (27 kg)
• Integral PID "tunable" temperature control (two styles)
• Ambient temperature up to +50°C
• No compressor, fluorocarbons or filters
• Virtually maintenance-free operation
• Remote Sensibility™
• Un-cooled, 500mL reservoir
• Front to back air-flow system
• Stainless steel exterior housing
• Low fluid level and low flow warning
• Integral power supply
• Self priming pump/reservoir
• Low pressure drop fluid quick connects
• Tubing and insulation
• 3/8" CPC low pressure drop shut off fittings |
Click on the image for a larger view

Click on the image for a larger view
View or request 3D solid model files for this product:
| Click on the image to view TLC-1400 3D PDF file: |
 |
Click on the image to open the PDF file

|
|
|
| |
- TLC-900
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
TLC-900 Series
Recirculating Liquid Chiller
Style: Bench Top
Voltages: 100-240 VAC, 24 VDC
Environments:
Bench Top
Laboratory
Industrial
|
Cooling capacity:
310 Watts @ 0 °C
ΔT (standard capacity)
310 Watts @ 0 °C
ΔT (high capacity)
Includes:
Pump and reservoir
Integral Power Supply
Integral TC-4300 Temperature control
RS-232 Communications
Remote Sensibility
|
Click on part number to request a quick quote
| MODEL |
PART NUMBER |
PUMP OPTION |
VOLTAGE VAC (VDC) |
CURRENT AMPS. |
WEIGHT LBS. (KG) |
MAX OPERATING TEMP °C |
FLUID TEMP RANGE °C |
| TLC-900 |
6-E4EB-1-0A1 |
1 |
100-240 |
3.5 |
42 (19) |
50 °C (+122 F) |
0 to 50 |
| TLC-900 |
6-E5EB-1-0A1 |
1 |
100-240 |
4 |
42 (19) |
50 °C (+122 F) |
0 to 50 |
| TLC-900 |
6-E4EB-1-0A2 |
2 |
100-240 |
3.5 |
42 (19) |
50 °C (+122 F) |
-20 to 90 |
| TLC-900 |
6-E5EB-1-0A2 |
2 |
100-240 |
4 |
42 (19) |
50 °C (+122 F) |
-20 to 90 |
| TLC-900 |
6-E4EB-1-0A3 |
3 |
100-240 |
3.5 |
42 (19) |
50 °C (+122 F) |
-20 to 90 |
| TLC-900 |
6-E5EB-1-0A3 |
3 |
100-240 |
4 |
42 (19) |
50 °C (+122 F) |
-20 to 90 |
| TLC-900 |
6-E4EB-1-0A4 |
4 |
100-240 |
3.5 |
42 (19) |
50 °C (+122 F) |
0 to 50 |
| TLC-900 |
6-E5EB-1-0A4 |
4 |
100-240 |
4 |
42 (19) |
50 °C (+122 F) |
0 to 50 |
| TLC-900 |
6-E4E5-1-0A1 |
1 |
(24) |
22 |
42 (19) |
50 °C (+122 F) |
0 to 50 |
| TLC-900 |
6-E4E5-1-0A2 |
2 |
(24) |
22 |
42 (19) |
50 °C (+122 F) |
-20 to 90 |
| TLC-900 |
6-E4E5-1-0A3 |
3 |
(24) |
22 |
42 (19) |
50 °C (+122 F) |
-20 to 9 |
| TLC-900 |
6-E4E5-1-0A4 |
4 |
(24) |
22 |
42 (19) |
50 °C (+122 F) |
0 to 50 |
Pump Options:
• Option #1 - Standard Magnetic Drive, Can Pump,
0 to 50 °C process temperature
• Option #2 - Low Temperature Magnetic Drive, Impeller Pump, -20 to 90 °C process temperature
• Option #3 - Gear pump, 3.75 Liter/Min, -20 to 90 °C process temperature
• Option #4 - High Flow Magnetic Drive, Can Pump,
0 to 50 °C process temperature |
Control Features:
•Integral TC-4300 PID "tunable" temperature control
•One shot smart PID control tuning or Adaptive Smart Continuous Tuning
•EasyLog software for easy programming, tuning, charting and data acquisition
•Heating and Cooling
•Internal RTD sensor
•Remote Sensibility™ switchable exterior sensor
•Multi-segment ramp and soak programmable(4X8 or 2X16 or 1X32 segments)
•RS-232 communications |
Click on the image for a larger view

Click on the image for a larger view

View or request 3D solid model files for this product:
| Click on the image to view TLC-900 3D PDF file: |
 |
Click on the image to open the PDF file

|
|
|
| |
- TLC-1200
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
TLC-1200 Series
Style: Bench Top and wall mount
Voltages: 24 VDC
Environments:
Bench Top
Laboratory
Industrial
|
Cooling capacity:
215 Watts @ 0 °C
ΔT
Includes:
3/8" OD stainless steel tubing
Integral H-Bridge for heat/cool operation
Two separate flow paths
Rubber feet
Power input leads
|
Click on part number to request a quick quote.
| MODEL |
PART NUMBER |
VOLTAGE VDC |
CURRENT AMPS. |
WEIGHT LBS. (KG) |
MAX OPERATING TEMP °C |
HEATING OPTION |
TEMP. CONTROL |
FLUID TEMP RANGE °C |
| TLC-1200 |
6-3095-0-000 |
24 |
9 |
20 (9.1) |
50 °C(+122 F) |
Cool Only |
None |
-5/65 |
| TLC-1200 |
6-3055-0-000 |
24 |
9 |
20 (9.1) |
50 °C(+122 F) |
Cool Only |
EXT* |
-5/65 |
| TLC-1200HC |
6-3055-1-000 |
24 |
9 |
20 (9.1) |
50 °C(+122 F) |
Heat/Cool |
EXT** |
-5/65 |
Click on the image for a larger view

Click on the image for larger view of the performance curve

|
Click on the image for larger view of the flow characteristic curve

|
Click on the image for a larger view

View or request 3D solid model files for this product:
| Click on the image to view TLC-1200 3D PDF file: |
 |
Click on the image to open the PDF file

|
|
| |
| |
- TLC-700
- Quote
- Picture
- Curves
- Drawing
- Solid Models
- Literature
- Applications
- Accessories
 |
TLC-700 Liquid Chiller
Recirculating Liquid Chiller
Style: Bench Top
Voltages: 120 VAC, 240 VAc, 24 VDC
Environments:
Bench Top
Laboratory
Industrial
|
Cooling capacity:
215 Watts @ 0 °C
ΔT
Includes:
Pump and reservoir
Integral Power Supply
Integral Temperature control (TC-3300)
RS-232 Communications (optional)
Remote Sensibility (optional)
|
Click on part number to request a quick quote.
| MODEL |
PART NUMBER |
VOLTAGE VAC (VDC) |
CURRENT AMPS. |
WEIGHT LBS. (KG) |
MAX OPERATING TEMP °C |
TEMP. CONTROL |
HEATING OPTION (HC SUFFIX) Watts |
FLUID TEMP RANGE °C |
APPROVALS (NRTL) |
| TLC-700 |
6-A0D0-0-000 |
120 |
4.2 |
32(14.5) |
50 °C(+122 F) |
|
TC-3300 |
-5/65 |
UL3101-1 CSA22.2, CE |
| TLC-700HC |
6-A0D0-1-000 |
120 |
4.2 |
32(14.5) |
50 °C(+122 F) |
200 Watt |
TC-3300 |
-5/65 |
UL3101-1 CSA22.2, CE |
| TLC-702 |
6-A0D2-0-000 |
240 |
2.9 |
42(19) |
50 °C(+122 F) |
|
TC-3300 |
-5/65 |
UL3101-1 CSA22.2, CE |
| TLC-702HC |
6-A0D2-1-000 |
240 |
2.9 |
42(19) |
50 °C(+122 F) |
200 Watt |
TC-3300 |
-5/65 |
UL3101-1 CSA22.2, CE |
Features:
• Compact (only 15.5" X 7.6" bench top footprint)
• Weighs approximately 32 lbs. (14.5 kg)
• Integral PID "tunable" temperature control (two styles)
• Ambient temperature up to +50°C
• No compressor, fluorocarbons or filters
• Virtually maintenance-free operation
• Remote Sensibility™
• Un-cooled, 500mL reservoir
• Front to back air-flow system
• Stainless steel exterior housing
• Low fluid level and low flow warning
• Integral power supply
• Self priming pump/reservoir
• Low pressure drop fluid quick connects
• Tubing and insulation
• 3/8" CPC low pressure drop shut off fittings |
Click on the image for a larger view

Click on the image for a larger view

View or request 3D solid model files for this product:
| Click on the image to view TLC-700 3D PDF file: |
 |
| Click on the image to view TLC-702 3D PDF file: |
 |
Click on the image to open the PDF file

|
|
|
| |
- TLC Cubes
- Quote
- Picture
- Curves
- Drawings
- Solid Models
- Literature
- Applications
- Accessories
 |
TLC Peltier Cooling Cubes
Description: Liquid chiller core
Voltages: Various DC inputs available
Requirement:
Pump, Power Supply, Tubing,
Fan and
Housing
|
Notes:
TECA model TLC³ cooling cubes are thermoelectric cooling “engines” that the engineer or designer can use in OEM systems.
Generally these are made in 100, 200 and 300 Watts capacity range, they work with a variety of fans.
Small or large quantities available.
|
Click on the image for a larger view

Click for larger view of the performance curve

|
Click for larger view of the flow curve

|
Click on the image for a larger view
View or request 3D solid model files for this product:
| Click on the image to view small TLC Cube 3D PDF file: |
 |
| Click on the image to view medium TLC Cube 3D PDF file: |
 |
| Click on the image to view large TLC Cube 3D PDF file: |
 |
Click on the image to open the PDF file

|
|
| |
| |
TECA's solid-state Recirculating Liquid Chillers for bench top use offer versatility, reliability and performance. Applications include quality control, sample heating and cooling, laboratory testing, laser cooling, manufacturing and more. Notably, the TLC-900 has been used in published research (see 50 Years of Innovation section on this website for details, 2012).
Versatility: Various input voltages are available for each model. Most models include an integral, programmable temperature controller. Heating is an available option on all models. Accessories are available including fittings and low-temperature cold plate attachments (cascades). The TLC3 solid-state Cooling Cubes provide a thermoelectric cooling "engine" around which you can build your own system. The TLC-1200 offers two separate cooling circuits.
Reliability: The solid-state (Peltier) construction is the perfect low-maintenance solution. There are no filters to change and no moving parts except for the fans. Our Peltier coolers use robust thermoelectric modules and boast a long service life.
Performance: Low-temperature cold plate (cascade) attachments can reach temperatures as low as -50C. Multiple features including RS-232 communications and data-logging software is included with the TLC-900 model.
|
|
| |
| |
|
|
| |
|
|
| |
Catalog | Sizing Software | Manuals | Applications | Site Map | Privacy Policy | Testimonials | Contact
© 2010 Thermoelectric Cooling America Corporation. All Rights Reserved.
|
|
|