Accessories For RLC-1800 Liquid Chillers
|
|
LCP-10-06 Liquid Cooled Cold Plate
Material: Aluminum body and copper tubing
Size: 6" X 5" X 0.7"
Includes: 12' Hose, insulation and fittings |
Turn your TLC water chiller into a direct contact cooler using this cold plate. Modify them with your required taps and machining, mount your components, run the flexible hose to the chiller and turn it on.
With care the remote sensor feature can be used to control the temperature of the plate or the item being cooled. |
|
|
|
LCP-10-12 Liquid Cooled Cold Plate
Material: Aluminum body and copper tubing
Size:12" X 5" X 0.7"
Includes: 12' Hose, insulation and fittings |
Turn your TLC water chiller into a direct contact cooler using this cold plate. Modify them with your required taps and machining, mount your components, run the flexible hose to the chiller and turn it on.
With care the remote sensor feature can be used to control the temperature of the plate or the item being cooled. |
|
|
|
FC10-01 Fan Coil
Material: Aluminum body and copper tubing
Size: 7.80" X 5.84" X 3.30"
Includes: 12' Hose, insulation and fittings |
Use your liquid chiller to cool an enclosure or a flow of air. Cool the inside of your glove box with little vibration and no big holes or air conditioner on the back. Mount the fan coils in your glove box, run the flexible tubing through a port or bulkhead fitting on your glove box to the TLC and begin cooling. |
|
|
|
FC10-01 Fan Coil
Material: Aluminum body and copper tubing
Size: 13" X 5.84" X 3.30"
Includes: 12' Hose, insulation and fittings |
Use your liquid chiller to cool an enclosure or a flow of air. Cool the inside of your glove box with little vibration and no big holes or air conditioner on the back. Mount the fan coils in your glove box, run the flexible tubing through a port or bulkhead fitting on your glove box to the TLC and begin cooling. |
|
|
|
RTD-Probe
Sensor Type: Three wire RTD, 100 Ω with connector
Length: 6' Minumum
Probe Size: 1/8 DIA X 6" long |
Click on the image for larger view
|
|
|
RTD-Ring
Sensor Type: Three wire RTD, 100 Ω with connector
Length: 6' Minumum
Mounting Style: Surface Mount |
Click on the image for larger view
|
|
|
C-USB
Function: USB to RS-232 converter (DB9 male) powered by USB port
Cable Length: 4"
Inculeds: Driver CD included
Supports: Windows, MAC, Linux |
· Special high gloss white finish enclosure design
· Looks and works great with MAC, PC and Linux platforms
· Enhanced RS232 transciever gives serial port speed of up to 1000K bps
· Adds one RS-232 serial port by connecting to USB port
· Installed as standard Windows COM port
· FIFO: 128 byte transmit buffer 384 byte receive buffer
· Works with USB 1.1 & 2.0 host port
· One DB9 male connector
· Serial Communication Parameters
· Parity: None, Even, Odd
· Data bits: 7, 8
· Flow control: RTS/CTS , DSR/DTR, X-ON/ X-OFF, None
· Gold plated USB and DB9 connectors for enhanced connection reliability
· Side-lit blue RX and TX traffic indicators
· integral 10cm USB cable with moulded strain relief
· Quality 4-layer pcb design
· COM Port Number assignment is configurable
· Uses latest FTDI "R" type chip set & drivers for maximum compatibility
· Compatible drivers for all current Windows, Mac and Linux operating systems.
· Full RS-232 modem control signals
· RS-232 data signals: TxD, RxD, RTS, CTS, DSR, DTR, DCD, RI, GND
· Powered by USB port. No external power adapter required.
|
|
|
C-485/232
Function: Bi directional RS-232 to RS-485 |
The C-485/232 is an industrial grade (wide temperature range with surge & static protection) port-powered
bi-directional RS-232 to RS-485 converter, which can be used to convert any standard RS-232C port into a two-wire RS-485 port and vice versa.
The unit is powered from the RS-232 data line; it also supports data direction auto-turnaround. Therefore, no external power or flow control is required. |
FEATURES
• Industrial grade with wide temperature range, surge and static protection.
• Port-powered, no external power or RTS, DTR required.
• Plug and play (hot-pluggable, data format auto-sensing and self-adjusting).
• Data direction auto-turnaround, no flow control is required.
• Built-in surge protection, static protection and circuit protection.
• Built-in 1201 end-of-line terminator for easy installation.
• Surface Mount Technology manufactured to ISO-9001 standards.
• CE certified.
INSTALLATION NOTES
• Connect PC’s (or other DTE device’s) COM port (or use a straight-through cable) to the RS-232 side of C-485/232, use a cross-over (Null-Modem) cable for DCE device.
• The 1201 end-of-line terminator adds heavy DC loading to a system; connect it only when the RS-485’s distance is over 660ft (200m).
• If C-485/232 is connected to any outdoor devices, please ensure that proper lightning protection is employed to prevent your devices from being damaged by lightning strikes.
|
|
|
C-RS232
Function: RS-232 M/F extension cable
Cable Length: 10 ft
Connectors: DB9 Male to DB9 Female
Note: All lines are wired straight through |
|
|
|
Quick Connect Fittings
Type: Standard and high temperature |
|
|
|
Filter And Screens
Low profile filter and filter screens |
|
|
|
Hose And Hose Insulation
Hose Type: Reinforced standard and high temperature
Insulation: Hose insulation (6' long) |
Click on the part number to order
Part Number |
Description |
HOSE-01 |
Standard hose, 3/8" ID (order by the foot) |
HOSE-02 |
High temperature hose, 3/8" ID (order by the foot) |
INS-01 |
Insulation for hose, 6' long segments |
|
|
|
|
|
|
|
|
|
|