FHP-3250 Series

Large Capacity Thermoelectric Air Conditioner

Large Capacity Thermoelectric Air Conditioner 1978 BTU/HR (580 watts) Enclosure Cooling, 48 VDC or 120 VAC Input with Power Save Mode:

Cool NEMA-12 enclosures, NEMA-4 enclosures and NEMA-4X/Harsh Environment enclosures with the thermoelectric FHP-3250-Series. This advanced Peltier-driven air conditioner will maintain both efficient cooling and the NEMA rating of your enclosure. The flush-mounted design of the FHP-3250 is ideal for control cabinets with little to no room for added equipment. The ECO-Mode temperature control feature helps save on power use. Designed to protect control cabinets, thermoelectric cooling technology (a.k.a. Peltier) is reliable and low-maintenance. Cool controls, electrical equipment, enclosures, and other heat sensitive equipment. Ideal for indoor or outdoor environments.

Protect your equipment from failure due to overheating. Choose low maintenance thermoelectric enclosure coolers from TECA for superior performance and reliability.

  • Mounting Style:Flush Mounted Voltage: 120 VAC, (48 VDC)
    Current: 7.0 AMPS, (22 AMPS)
    Operating Ambient: -40/+70 °C
    Operating Enclosure: -10/+60 °C
    Environments: Nema-12, Nema-4, Nema-4X/Harsh Environment

    Performance Rating:
    Cooling (Traditional):
    1978 BTU/HR
    Cooling (Din 3168): 580 WATTS
    Cooling COP (at L35 L35): 0.7
    Heating (Traditional): >2780 BTU/HR
    Heating (Din 3168): >815 WATTS
    Heating COP: >1.0

      

    Includes:
    • Power supply
    • Temperature controller
    • Power saving heat exchanger mode (ECO-Mode)
    • Mounting gasket
    • Mounting hardware
    • Power input cord
    • Circuit breaker

    Controller Features:
    TC-4F: Active cool 35 °C; ECO-Mode 25 °C
    TC-7F: Active cool 35 °C; Active heat 15 °C; ECO-Mode 25 °C

  • Click on the part numbers to request a quick quote:
    MODEL NUMBERPART NUMBERNOTESCONTROLLERENVIRONMENTCURRENT
    AMPS
    ENVIRONMENT
    FHP-32507-I4J0-0-000
    Cool onlyTC-4F1207NEMA-12, IP 52
    FHP-32507-I450-0-000
    Cool only3-32 VDC External signal1207NEMA-12, IP 52
    FHP-3250HC7-I4I0-1-000
    Heat/CoolTC-7F1207NEMA-12, IP 52
    FHP-3250HC7-I450-1-000
    Heat/Cool3-32 VDC External signal1207NEMA-12, IP 52
    FHP-3250XE7-I4J0-4-000
    Cool onlyTC-4F1207NEMA-4/4X, IP 56
    FHP-3250XE7-I450-4-000
    Cool only3-32 VDC External signal1207NEMA-4/4X, IP 56
    FHP-3250XEHC7-I4I0-5-000
    Heat/CoolTC-7F1207NEMA-4/4X, IP 56
    FHP-3250XEHC7-I450-5-000
    Heat/Cool3-32 VDC External signal1207NEMA-4/4X, IP 56
    FHP-3250X7-I4J0-2-000
    Cool onlyTC-4F1207NEMA-4X/Harsh Environment, IP 56
    FHP-3250X7-I450-2-000
    Cool only3-32 VDC External signal1207NEMA-4X/Harsh Environment, IP 56
    FHP-3250XHC7-I4I0-3-000
    Heat/CoolTC-7F1207NEMA-4X/Harsh Environment, IP 56
    FHP-3250XHC7-I450-3-000
    Heat/Cool3-32 VDC External signal1207NEMA-4X/Harsh Environment, IP 56
    FHP-32507-I5J6-0-000
    Cool onlyTC-4F(48)22NEMA-12, IP 52
    FHP-32507-I556-0-000
    Cool only3-32 VDC External signal(48)22NEMA-12, IP 52
    FHP-3250HC7-I5I6-1-000
    Heat/CoolTC-7F(48)22NEMA-12, IP 52
    FHP-3250HC7-I556-1-000
    Heat/Cool3-32 VDC External signal(48)22NEMA-12, IP 52
    FHP-3250XE7-I5J6-4-000
    Cool onlyTC-4F(48)22NEMA-4/4X, IP 56
    FHP-3250XE7-I556-4-000
    Cool only3-32 VDC External signal(48)22NEMA-4/4X, IP 56
    FHP-3250XEHC7-I5I6-5-000
    Heat/CoolTC-7F(48)22NEMA-4/4X, IP 56
    FHP-3250XEHC7-I556-5-000
    Heat/Cool3-32 VDC External signal(48)22NEMA-4/4X, IP 56
    FHP-3250X7-I5J6-2-000
    Cool onlyTC-4F(48)22NEMA-4X/Harsh Environment, IP 56
    FHP-3250X7-I556-2-000
    Cool only3-32 VDC External signal(48)22NEMA-4X/Harsh Environment, IP 56
    FHP-3250XHC7-I5I6-3-000
    Heat/CoolTC-7F(48)22NEMA-4X/Harsh Environment, IP 56
    FHP-3250XHC7-I556-3-000
    Heat/Cool3-32 VDC External signal(48)22NEMA-4X/Harsh Environment, IP 56
  • Click to download:

    Solid Model files:
    TypeFile NameDate ModifiedSize

    IGS
    Fhp 3200 9:17 am 09/01/201619.2M

    PDF
    Fhp 3200 9:17 am 09/01/2016665.8k

    SLDP
    Fhp 3200 9:17 am 09/01/20163.8M

    STEP
    Fhp 3200 9:18 am 09/01/201612.6M

    dwg
    Fhp 3200 9:16 am 09/01/20164M
  • Part NumberDescriptionDrawingData Sheet
    EH-2001200 Watts Enclosure heater
    120 VAC
    dwgpdf
    EH-2002200 Watts Enclosure heater
    240 VAC
    dwgpdf
    EH-4001400 Watts Enclosure heater
    120 VAC
    dwgpdf
    EH-4002400 Watts Enclosure heater
    240 VAC
    dwgpdf
    D-100Condensate discharge, plasticpdf
    D-200Condensate discharge, ST.ST.pdf

Features:
• High capacity thermoelectric design
• Power saving air to air heat exchanger mode (ECO-Mode)
• Heavy duty full perimeter mounting
• No intrusion into enclosure
• Central input cord for easy mounting
• Closed loop design
• Condensate control and evaporation system
• Increased efficiency at higher ambients
• Virtually maintenance free
• No compressor
• Environmentaly friendly and safe
• Stainless Steel exterior housing
• Mounts and operates in any orientation
• Integral temperature controller
• Weight 93 LBS.
• UL 60335-1 & 2-40; CSA C22.2#60335-1 & 2-40
• IEC 60335-1 & 2-40
• CENELEC EN 61000-6-2 & EN 61000-6-4


Resources: