Magnetic Stirring Cold/Hot Plate For Laboratory Use
Style: Bench Top, Laboratory
Voltage: 100-240 VAC
Current: 6.0-2.5 AMPS
Operating Ambient: 0/+45 °C
Requirements:
The AHP-1200MSP must be used with either ICE-1200MSP Ice Bucket or one of the SLV-XXXMSP Cold Shoe accessories.
• SLV-XXXMSP Cold Shoe accessory for direct contact cooling/heating of specific beakers and vessels
OR
•ICE-1200MSP Ice Bucket accessory for cooling/heating of beakers and vessels of various sizes and shapes without the need for special fixture or rackIncludes:
• Integral Power Supply
• Integral PWM Temperature control
• USB comms port
• Remote SensibilityController Features:
• Integral “tunable” PWM temperature control
• PWM, Bi-directional temperature control
• 4 Temperature zone with 4 independent PID settings
• Multi-segment ramp and soak programmable
• Internal RTD sensor
• Remote Sensibility™ switchable to exterior accessory RTD sensor
• USB Communication with easy to use software
• Labview VI examples- Click on the part numbers to request a quick quote:
MODEL NUMBER PART NUMBER VOLTAGE
VAC (VDC)CURRENT
AMPSAHP-1200MSP 9-35KB-1-MSP
100-240 6.0 - 2.5 The AHP-1200MSP must be used with either ICE-1200MSP Ice Bucket or one of the SLV-XXXMSP Cold Shoe accessories (order separately)!3.15 [80]
SLV-XXXMSP Cold Shoe accessories part numbers and specifications:
PART NUMBER BEAKER
TYPEVOLUME
mLBEAKER DIAMETER
in [mm]BEAKER
Height
in [mm]SLV-1000LMSP Griffin Low Form 1000 4.25 [108] 6.2 [158] SLV-1000HMSP Berzelius Tall Form 1000 3.5 [89] 7.36 [187] SLV-1500MSP Griffin Low Form 1500 4.76 [121] 6.5 [166] SLV-2000MSP Griffin Low Form 2000 5.16 [131] 7.6 [193] SLV-3000MSP Griffin Low Form 3000 5.75 [146] 8.5 [216] SLV-4000MSP Griffin Low Form 4000 6.3 [160] 9.8 [250] SLV-5000MSP Griffin Low Form 5000 6.7 [170] 10.6 [270] - Click to open files:
- Click to download:
Solid Model files:
Product Manuals, Software:
- • tecaLAB Thermal Lab Beads™ for ICE-1200MSP Ice Bucket (ICE-1200MSP includes 3 liters of thermal Lab Beads™)
PART NUMBER BEAKER
TYPEVOLUME
mLBEAKER DIAMETER
in [mm]BEAKER
Height
in [mm]SLV-1000LMSP Griffin Low Form 1000 4.25 [108] 6.2 [158] SLV-1000HMSP Berzelius Tall Form 1000 3.5 [89] 7.36 [187] SLV-1500MSP Griffin Low Form 1500 4.76 [121] 6.5 [166] SLV-2000MSP Griffin Low Form 2000 5.16 [131] 7.6 [193] SLV-3000MSP Griffin Low Form 3000 5.75 [146] 8.5 [216] SLV-4000MSP Griffin Low Form 4000 6.3 [160] 9.8 [250] SLV-5000MSP Griffin Low Form 5000 6.7 [170] 10.6 [270] Features:
• PWM temperature control
• Fluid process temperature range 0 °C to 50 °C
• Internal and external RTD sensor
• Adjustable stirring from 100 to 1000 RPM
• Accommodates many vessel sizes
• Stainless steel, aluminum and acrylic construction
• Doubles as an Electric Ice BucketTM when not used for stirring
• Always On, Always Cold design: plug it in and leave it on indefinitely
• Samples stay where you place them without racks or fixtures
• No more floating or tipping samples
• Holds capped and non-watertight vessels in place
• Certified to CSA STDS C22.2 # 61010-1 & 61010-2-010
• FCC 47CFR PT 15: 2019; IEC 61326-1