TEMPERATURE PREFERENCE TESTING

Temperature Preference Testing:

temperature preference temperature preference temperature preference

 

Creating Microclimates for Insect Subjects

Using TECA’s Gradient Bar System, a biology department at a U.S. university created a temperature preference device for small insects.

The insects were infected with various pathogens. The researchers wanted to create an environment where the insects chose a temperature benefiting pathogen replication/transmission and not host survival, thus determining whether pathogens alter their hosts’ temperature preferences.

Insulating their petri dishes and setting the entire gradient machine inside a larger incubator, the researchers created a microclimate and had excellent control over temperature fluctuations.

TEMPERATURE GRADIENT

Agricultural Research Using Temperature Gradient:

temperature gradient temperature gradient

 

A department of the Canadian government uses two TECA Thermal Gradient Bar (TGB-5030) systems to conduct thermal behavior research on insects.

In the photographs shown here, the customer used two AHP-1200CPV Cold/Hot plates plus one Large Gradient Plate (p/n TGB-5030) and created a gradient area spanning from 4 °C to 33 °C. Two groups of insects were placed side-by-side on the gradient bar, in separate cages. This allowed the researchers to test two groups at the same time.

THERMAL GRADIENT BAR

Thermal Gradient Bar:

thermal gradient bar

The gradient plate shown is not TECA’s. It’s from a University. They had been running a hot plate on one end and a liquid cooled LHP-300CP with the plate in the evaluation of temperature preference in insects.

They needed better control and a wider temperature range and they wanted it on their existing plate. Many tests were run with the AHP-301CPV (shown) and the AHP-1200CPV to evaluate temperature uniformity and differential.

More and more researchers are looking into the versatile CPV line of cold plates to improve their tests with the CPV line of products and accessories. Call us. Maybe we can help you too.

BATTERY COOLING

R & D Battery Cooling:

battery cooling

In this example, the customer is using TECA’s AHP-1800CPV to keep a 60 pound lithium ion battery cool during R&D testing. This saves the customer the trouble of using a plate with pumped coolant to cool the battery, which was the original method.

The customer reports that upgrading to the TECA AHP-1800CPV “makes testing much easier”.

The AHP-1800CPV is the largest thermoelectric cold plate on the market with a plate surface area of 12.80 x 13.30 inches.  The large surface area and robust cooling power were ideal for this application.

FIBER OPTICS

Fiber Optics:

optics optics

 

A research and development team in Europe uses the TECA Model AHP-1200CPV Cold Plate with a TECA Model TC-1 Tube Chiller attached.

Their process is proprietary but involves optical material and measurements. The TC-1 Tube Chiller is designed to heat or cool fluid without introducing contaminants to the fluid.

The fluid flows through the flexible tubing (various tubing diameters are possible) within the plate surface.

FIBER OPTICS

Fiber Optics:

fiber optics

The customer makes fiber optics and related components and subsystems, they use an AHP-1200CPV cold plate for testing components.

They are using it to run temperature test on them, they set the temperature, and it goes to temperature and sits there, heating or cooling.

“It works well”.  Before they were cobbling together home brew solutions with a heater here, a circuit and a fan there but it’s nice to have a system that does it all.

COOLING ASPHALT SAMPLES

Cooling Asphalt Samples:

cooling asphalt samples

An oil refinery runs tests on asphalt samples at different temperatures.

TECA Model AHP-301CPV Cold Plate is currently being used during the course of the customer’s testing.

The customer says, “We have used this unit at different temperatures, and it has performed well. Thank you for your follow-up on the performance of this device.”

HIGH SPEED CRYSTAL OSCILLATORS

High Speed Crystal Oscillators:

High Speed Crystal Oscillators

The customer makes high performance crystal oscillators and atomic clocks for satellites and laboratories and they needed something for temperature control and stabilization.

They found TECA and the AHP-301CPV, tried one and say it is “working fantastic”. Well enough to order more for production, quality and engineering tests. They use them to maintain a stable temperature of the oscillator which in turn provides a stable frequency.

COOLING MOUNTING WAX

Cooling Mounting Wax:

cooling mounting wax cooling mounting wax

 

A product design engineer at a medical device company needed a way to cool wax blocks holding film. The wax is printed directly onto the customer’s aluminum tray. Before discovering TECA products, the customer was placing the aluminum tray in a refrigerator and mechanically removing the wax by scraping it off with a metal blade.

TECA’s AHP-1200CP Cold Plate is a better solution. The customer is happy to have found an affordable cold plate to dedicate to his cooling task.

Please view the video provided by our customer to see how quickly and easily the wax is now removed (no more scraping!).

CHEMICAL WASTE TRANSPORT

Chemical Waste Transport:

chemical waste transport

Here’s an application that our engineering crew would love to put into greater use if they could figure out where and how. A specialty gas company called. They wanted to transfer toxic and corrosive liquids from big to small containers for lab use. The process had been taking several minutes with too much wasted product.

They knew because of the conditions a natural head pressure in the big container that they could use a cold plate to cool at the receiving vessel (Ø 1.5″ x 12″ bottle) to create a driving force which moves the fluid.

We didn’t go into the physics of this, we trusted what the customer said and worked with them. When they tried an AHP-1200CP it was fantastic. It turned 4 minutes and a lot of waste into no waste and 40 seconds.