Thermoelectric Air Conditioner
Climate Control for NEMA-12, NEMA-4/4X, Harsh/Mil Duty, CID2 and CID1 530 BTU/HR (154 watts), For AC or DC Input Voltage:
For cooling NEMA cabinets, the AHP-1200-Series is an important and incredibly popular legacy product. The AHP-1200-Series is a thermoelectric air conditioner designed to protect electronics equipment boxes from overheating. Utilizing reliable Peltier cooling (and heating when needed!) technology, AHP-1200 coolers protect electronic controls, electrical equipment, equipment cabinets, railway controls, alarms, crane controls, automation equipment controls, and other heat sensitive equipment.
Versatile choices allow for use in 24 vdc, 48 vdc, 120 VAC and 240 VAC areas. Serving every environment rating including NEMA-12/4/4X, Harsh/Mil Duty, and Hazardous Locations. Protect against equipment box failure due to overheating. Choose low maintenance TECA air conditioners for superior performance and reliable climate control.
Mounting Style: Through Mounted
The through mounted (AHP) enclosure coolers will intrude a few inches into and out of the enclosure
Voltage: 120 VAC, 240 VAC, 24 VDC, 48 VDC
Current: 4.5 AMPS, 2.5 AMPS, 9 AMPS, 4.5 AMPS
Operating Ambient: -40°C up to +71°C (see data sheets)
Operating Enclosure: -10/+60 °C
Environments: Nema-12Nema-12 enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids., Nema-4/4XNema-4/4X enclosures are intended for indoor or outdoor use to provide protection against windblown dust and rain, splashing and hose-directed water and ice forming damage., Nema-4X/Harsh EnvironmentNema-4X/Harsh Environment enclosures are intended for indoor and outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose directed water TECA products carrying the “X” designation use Mil-Spec fans, o-ring sealed power supplies, no exposed electronic components, stud/gasket mounting and Mil-Spec finishes.
Performance Rating:
Cooling (Traditional): 530 BTU/HR
Cooling (Din 3168): 154 WATTS
Cooling COP (at L35 L35): 0.71 (DC version)

Includes:
• Temperature controller
• Mounting gasket
• Mounting hardware
• Power input lead or cord
Controller Features:
TC-1F: Active cool 35 °C
TC-6F: Active cool 25 °C or 35 °C
TC-3F: Active cool 35 °C; Active heat 15 °C
TC-7F: Active cool 35 °C; Active heat 15 °C; ECO-Mode 25 °C
- Click on the part numbers to request a quick quote:
NEMA-12/IndoorsNEMA-4/4X/OutdoorsNEMA-4X/Harsh EnvironmentHaz. Loc.
| MODEL |
PART NUMBER |
VOLTAGE VAC |
CURRENT AMPS |
WEIGHT LB. (KG) |
TEMPERATURE CONTROL |
OPERATING AMBIENT TEMPERATURE RANGE °C |
OPERATING ENCLOSURE TEMPERATURE RANGE °C |
ENVIRONMENT |
| AHP-1200EP |
0-3080-0-003 |
120 |
4.0 |
21(9.5) |
TC-6F |
-40/+63 |
-10/+60 |
NEMA-12 |
| AHP-1200EP |
0-30F0-0-004 |
120 |
4.0 |
21(9.5) |
85°F (30°C) |
-40/+63 |
-10/+60 |
NEMA-12 |
| AHP-1200EP-1 |
0-3070-0-010 |
120 |
4.0 |
21(9.5) |
EXT* |
-40/+63 |
-10/+60 |
NEMA-12 |
| AHP-1200EPHC |
0-3030-1-007 |
120 |
4.0 |
21(9.5) |
TC-3F |
-40/+63 |
-10/+60 |
NEMA-12 |
| AHP-1200EPHC-1 |
0-3070-1-009 |
120 |
4.0 |
21(9.5) |
EXT* |
-40/+63 |
-10/+60 |
NEMA-12 |
| AHP-1200XEP |
0-3080-4-003 |
120 |
4.0 |
21(9.5) |
TC-6F |
-40/+63 |
-10/+60 |
NEMA-4/4X |
| AHP-1200XEP |
0-30F0-4-004 |
120 |
4.0 |
21(9.5) |
85°F (30°C) |
-40/+63 |
-10/+60 |
NEMA-4/4X |
| AHP-1200XEP-1 |
0-3070-4-010 |
120 |
4.0 |
21(9.5) |
EXT* |
-40/+63 |
-10/+60 |
NEMA-4/4X |
| AHP-1200XEPHC |
0-3030-5-007 |
120 |
4.0 |
21(9.5) |
TC-3F |
-40/+63 |
-10/+60 |
NEMA-4/4X |
| AHP-1200XEPHC-1 |
0-3070-5-009 |
120 |
4.0 |
21(9.5) |
EXT* |
-40/+63 |
-10/+60 |
NEMA-4/4X |
| AHP-1200XP |
0-3080-2-003 |
120 |
4.0 |
21(9.5) |
TC-6F |
-40/+71 |
-10/+60 |
NEMA-4X/Harsh |
| AHP-1200XP |
0-30F0-2-004 |
120 |
4.0 |
21(9.5) |
85°F (30°C) |
-40/+71 |
-10/+60 |
NEMA-4X/Harsh |
| AHP-1200XP-1 |
0-3070-2-010 |
120 |
4.0 |
21(9.5) |
EXT* |
-40/+71 |
-10/+60 |
NEMA-4X/Harsh |
| AHP-1200XPHC |
0-3030-3-007 |
120 |
4.0 |
21(9.5) |
TC-3F |
-40/+71 |
-10/+60 |
NEMA-4X/Harsh |
| AHP-1200XPHC-1 |
0-3070-3-009 |
120 |
4.0 |
21(9.5) |
EXT* |
-40/+71 |
-10/+60 |
NEMA-4X/Harsh |
| AHP-1201EP |
0-3081-0-003 |
120/240 |
4.0/2.0 |
29(13.2) |
TC-6F |
-40/+63 |
-10/+60 |
NEMA-12 |
| AHP-1201EP |
0-30F1-0-004 |
120/240 |
4.0/2.0 |
29(13.2) |
85°F (30°C) |
-40/+63 |
-10/+60 |
NEMA-12 |
| AHP-1201EP-1 |
0-3071-0-010 |
120/240 |
4.0/2.0 |
29(13.2) |
EXT* |
-40/+63 |
-10/+60 |
NEMA-12 |
| AHP-1201EPHC |
0-3031-1-007 |
120/240 |
4.0/2.0 |
29(13.2) |
TC-3F |
-40/+63 |
-10/+60 |
NEMA-12 |
| AHP-1201EPHC-1 |
0-3071-1-009 |
120/240 |
4.0/2.0 |
29(13.2) |
EXT* |
-40/+63 |
-10/+60 |
NEMA-12 |
| AHP-1201XEP |
0-3081-4-003 |
120/240 |
4.0/2.0 |
29(13.2) |
TC-6F |
-40/+63 |
-10/+60 |
NEMA-4/4X |
| AHP-1201XEP |
0-30F1-4-004 |
120/240 |
4.0/2.0 |
29(13.2) |
85°F (30°C) |
-40/+63 |
-10/+60 |
NEMA-4/4X |
| AHP-1201XEP-1 |
0-3071-4-010 |
120/240 |
4.0/2.0 |
29(13.2) |
EXT* |
-40/+63 |
-10/+60 |
NEMA-4/4X |
| AHP-1201XEPHC |
0-3031-5-007 |
120/240 |
4.0/2.0 |
29(13.2) |
TC-3F |
-40/+63 |
-10/+60 |
NEMA-4/4X |
| AHP-1201XEPHC-1 |
0-3071-5-009 |
120/240 |
4.0/2.0 |
29(13.2) |
EXT* |
-40/+63 |
-10/+60 |
NEMA-4/4X |
| AHP-1201XP |
0-3081-2-014 |
120/240 |
4.0/2.0 |
29(13.2) |
TC-6F |
-40/+71 |
-10/+60 |
NEMA-4X/Harsh |
| AHP-1201XP |
0-30F1-2-020 |
120/240 |
4.0/2.0 |
29(13.2) |
85°F (30°C) |
-40/+71 |
-10/+60 |
NEMA-4X/Harsh |
| AHP-1201XP-1 |
0-3071-2-012 |
120/240 |
4.0/2.0 |
29(13.2) |
EXT* |
-40/+71 |
-10/+60 |
NEMA-4X/Harsh |
| AHP-1201XPHC |
0-3031-3-011 |
120/240 |
4.0/2.0 |
29(13.2) |
TC-3F |
-40/+71 |
-10/+60 |
NEMA-4X/Harsh |
| AHP-1201XPHC-1 |
0-3071-3-013 |
120/240 |
4.0/2.0 |
29(13.2) |
EXT* |
-40/+71 |
-10/+60 |
NEMA-4X/Harsh |
-