COOLING GAS FLOW

Cooling Gas FLow:

A potential customer expressed interest in a cooling/heating system for an aerosol flow tube envisioning a 1 inch OD, 0.875 inch ID stainless steel flow tube mounted inside a 2-2.5 inch ID pipe (likely also stainless steel and insulated on the outside) capable of controlling the tube at temperatures ranging from roughly 5 °C to 40 °C at an ambient temperature of 25-30 °C.  We are measuring the change in particulates in the air due to the temp change.

cooling gas flow cooling gas flow

Standard liquid chillers were first offered along with technical design assistance. The requirements led to direct contact cooling as being a good solution. Standard cold plate products and controllers were offered which led to this request for a custom package. “We would like to have the flow tube sandwiched between the cold plates with the temperature controller and power supplies attached in a similar manner so that we only need attach the temperature controller (the TC-3400 appears as if it will work) to a computer so that we can change the set points remotely.

Is any of this even possible or am I dreaming in Technicolor?” We advised him that the best dreams were in color. Preliminary design work was done and a quote prepared. Shortly thereafter an order was received; design documents were completed and sent to production. Less than 3 months after the initial contact the product was shipped. Several months later a follow up was made with this response.

“Things are doing really well. It does exactly what we wanted it to do, and is much more efficient and better than we hoped for. We’re very happy!

BEVERAGE COOLING IN A BARREL

Beverage Cooling in a barrel:

beverage cooling in a barrel beverage cooling in a barrel

Here’s an application that TECA’s engineering team was particularly excited about. Not because of the economics or the potential new business. Frankly we didn’t think the market was there. But as soon as they found out that a ½ barrel of beer would be needed for testing they were all over it. While none was ever sold, good lessons regarding contact methods and material stratification were learned. To see the result of the test click here.
We used an AHP-1200CP thermoelectric cold plate and a TLC-700 thermoelectric liquid chiller for testing purpose.

FLUID DISPENSING

Fluid Dispensing:

fluid dispensing

A leading manufacturer of fluid dispensing systems uses one of our Thermoelectric Cold Plate and Temperature Controller for controlling the fluid temperature of adhesives, sealants, lubricants and other materials in meter, mix and dispensing systems.
Unlike other larger, higher cost and less accurate heating and cooling devices, which use heater cartridges, refrigerant or water to heat and cool, these thermoelectric-effect temperature controllers use the Peltier-Seebeck effect to directly convert electrical voltage to thermal differentials. This effect, which is reversible, either heats or cools fluid materials with precision to the temperature set point. The compact Peltier thermoelectric device, temperature sensor and the temperature control is mounted to a manifold where the fluid passes through to be precisely heated, maintained or cooled.

COOLING PURE FLUID FLOW

Cooling Pure Fluid Flow:

cooling pure fluid flow cooling pure fluid flow

The customer needed to cool a very low flow rate of a very pure fluid. Passing tubing through an ice bath did not provide close enough and consistent enough temperature control. However by using the AHP-1200CPV with tube chiller option and by determining the optimum set point a consistently cooled flow of the pure fluid was obtained.

FLUE GAS ANALYSIS

Flue Gas Analysis:

flue gas analysis flue gas analysis

The customer uses the TECA TLC-702HC in a heating and cooling process in a laboratory setting. The customer’s PSA system is removing CO2 from flue gas and drying and analyzing the flue gas. The TLC-702HC is available in 120 or 240 VAC versions. Heat/Cool or Cool-Only configurations are available.

FHP-3250 Series

Large Capacity Thermoelectric Air Conditioner

Large Capacity Thermoelectric Air Conditioner 1978 BTU/HR (580 watts) Enclosure Cooling, 48 VDC or 120 VAC Input with Power Save Mode:

Cool NEMA-12 enclosures, NEMA-4 enclosures and NEMA-4X/Harsh Environment enclosures with the thermoelectric FHP-3250-Series. This advanced Peltier-driven air conditioner will maintain both efficient cooling and the NEMA rating of your enclosure. The flush-mounted design of the FHP-3250 is ideal for control cabinets with little to no room for added equipment. The ECO-Mode temperature control feature helps save on power use. Designed to protect control cabinets, thermoelectric cooling technology (a.k.a. Peltier) is reliable and low-maintenance. Cool controls, electrical equipment, enclosures, and other heat sensitive equipment. Ideal for indoor or outdoor environments.

Protect your equipment from failure due to overheating. Choose low maintenance thermoelectric enclosure coolers from TECA for superior performance and reliability.

  • Mounting Style:Flush Mounted Voltage: 120 VAC, (48 VDC)
    Current: 7.0 AMPS, (22 AMPS)
    Operating Ambient: -40/+70 °C
    Operating Enclosure: -10/+60 °C
    Environments: Nema-12, Nema-4, Nema-4X/Harsh Environment

    Performance Rating:
    Cooling (Traditional):
    1978 BTU/HR
    Cooling (Din 3168): 580 WATTS
    Cooling COP (at L35 L35): 0.7
    Heating (Traditional): >2780 BTU/HR
    Heating (Din 3168): >815 WATTS
    Heating COP: >1.0

      

    Includes:
    • Power supply
    • Temperature controller
    • Power saving heat exchanger mode (ECO-Mode)
    • Mounting gasket
    • Mounting hardware
    • Power input cord
    • Circuit breaker

    Controller Features:
    TC-4F: Active cool 35 °C; ECO-Mode 25 °C
    TC-7F: Active cool 35 °C; Active heat 15 °C; ECO-Mode 25 °C

  • Click on the part numbers to request a quick quote:
    MODEL NUMBERPART NUMBERNOTESCONTROLLERENVIRONMENTCURRENT
    AMPS
    ENVIRONMENT
    FHP-32507-I4J0-0-000
    Cool onlyTC-4F1207NEMA-12, IP 52
    FHP-32507-I450-0-000
    Cool only3-32 VDC External signal1207NEMA-12, IP 52
    FHP-3250HC7-I4I0-1-000
    Heat/CoolTC-7F1207NEMA-12, IP 52
    FHP-3250HC7-I450-1-000
    Heat/Cool3-32 VDC External signal1207NEMA-12, IP 52
    FHP-3250XE7-I4J0-4-000
    Cool onlyTC-4F1207NEMA-4/4X, IP 56
    FHP-3250XE7-I450-4-000
    Cool only3-32 VDC External signal1207NEMA-4/4X, IP 56
    FHP-3250XEHC7-I4I0-5-000
    Heat/CoolTC-7F1207NEMA-4/4X, IP 56
    FHP-3250XEHC7-I450-5-000
    Heat/Cool3-32 VDC External signal1207NEMA-4/4X, IP 56
    FHP-3250X7-I4J0-2-000
    Cool onlyTC-4F1207NEMA-4X/Harsh Environment, IP 56
    FHP-3250X7-I450-2-000
    Cool only3-32 VDC External signal1207NEMA-4X/Harsh Environment, IP 56
    FHP-3250XHC7-I4I0-3-000
    Heat/CoolTC-7F1207NEMA-4X/Harsh Environment, IP 56
    FHP-3250XHC7-I450-3-000
    Heat/Cool3-32 VDC External signal1207NEMA-4X/Harsh Environment, IP 56
    FHP-32507-I5J6-0-000
    Cool onlyTC-4F(48)22NEMA-12, IP 52
    FHP-32507-I556-0-000
    Cool only3-32 VDC External signal(48)22NEMA-12, IP 52
    FHP-3250HC7-I5I6-1-000
    Heat/CoolTC-7F(48)22NEMA-12, IP 52
    FHP-3250HC7-I556-1-000
    Heat/Cool3-32 VDC External signal(48)22NEMA-12, IP 52
    FHP-3250XE7-I5J6-4-000
    Cool onlyTC-4F(48)22NEMA-4/4X, IP 56
    FHP-3250XE7-I556-4-000
    Cool only3-32 VDC External signal(48)22NEMA-4/4X, IP 56
    FHP-3250XEHC7-I5I6-5-000
    Heat/CoolTC-7F(48)22NEMA-4/4X, IP 56
    FHP-3250XEHC7-I556-5-000
    Heat/Cool3-32 VDC External signal(48)22NEMA-4/4X, IP 56
    FHP-3250X7-I5J6-2-000
    Cool onlyTC-4F(48)22NEMA-4X/Harsh Environment, IP 56
    FHP-3250X7-I556-2-000
    Cool only3-32 VDC External signal(48)22NEMA-4X/Harsh Environment, IP 56
    FHP-3250XHC7-I5I6-3-000
    Heat/CoolTC-7F(48)22NEMA-4X/Harsh Environment, IP 56
    FHP-3250XHC7-I556-3-000
    Heat/Cool3-32 VDC External signal(48)22NEMA-4X/Harsh Environment, IP 56
  • Click to download:

    Solid Model files:
    TypeFile NameDate ModifiedSize

    IGS
    Fhp 3200 9:17 am 09/01/201619.2M

    PDF
    Fhp 3200 9:17 am 09/01/2016665.8k

    SLDP
    Fhp 3200 9:17 am 09/01/20163.8M

    STEP
    Fhp 3200 9:18 am 09/01/201612.6M

    dwg
    Fhp 3200 9:16 am 09/01/20164M
  • Part NumberDescriptionDrawingData Sheet
    EH-2001200 Watts Enclosure heater
    120 VAC
    dwgpdf
    EH-2002200 Watts Enclosure heater
    240 VAC
    dwgpdf
    EH-4001400 Watts Enclosure heater
    120 VAC
    dwgpdf
    EH-4002400 Watts Enclosure heater
    240 VAC
    dwgpdf
    D-100Condensate discharge, plasticpdf
    D-200Condensate discharge, ST.ST.pdf

Features:
• High capacity thermoelectric design
• Power saving air to air heat exchanger mode (ECO-Mode)
• Heavy duty full perimeter mounting
• No intrusion into enclosure
• Central input cord for easy mounting
• Closed loop design
• Condensate control and evaporation system
• Increased efficiency at higher ambients
• Virtually maintenance free
• No compressor
• Environmentaly friendly and safe
• Stainless Steel exterior housing
• Mounts and operates in any orientation
• Integral temperature controller
• Weight 93 LBS.
• UL 60335-1 & 2-40; CSA C22.2#60335-1 & 2-40
• IEC 60335-1 & 2-40
• CENELEC EN 61000-6-2 & EN 61000-6-4


Resources:

Air conditioner Notes

Applications

Accessories

Manuals

Sizing Software

Contact Us

AHP-1800 Series

Thermoelectric Air Conditioner

Cooling Industrial and Military Enclosures NEMA-4/4X, NEMA-12, Hazardous Location CID2 & CID1, Harsh and Mil Duty 1098 BTU/HR (322 watts), AC or DC Input Voltage:

For cooling and heating NEMA-12/4/4X cabinets, the AHP-1800-Series is an important and incredibly popular legacy product for climate control. The AHP-1800-Series is a Peltier air conditioner designed to protect electronics equipment boxes from overheating. Thermoelectric cooling technology reliably cools (or heats) your enclosures to protect electronic controls, electrical equipment, control cabinets, and other heat sensitive equipment.

This thermoelectric cabinet cooler accepts 24 vdc, 48 vdc, 120 VAC and 240 VAC input. It can cool while maintaining environment ratings: NEMA-12/4/4X, Harsh/Mil Duty, and Hazardous Locations CID1/CID2. Protect against equipment failure due to overheating. Choose low maintenance TECA air conditioners for superior performance and reliable climate control.

  • Mounting Style: Through Mounted

    Voltage: 120/240 VAC, 24 VDC, 48 VDC
    Current: 8/5 AMPS, 18 AMPS, 9 AMPS
    Operating Ambient: -40°C up to +75°C (see data sheets)
    Operating Enclosure: -10/+60 °C
    Environments: Nema-12, Nema-4/4X, Nema-4X/Harsh Environment

    Performance Rating:
    Cooling (Traditional):
    1100 BTU/HR
    Cooling (Din 3168): 322 WATTS
    Cooling COP (at L35 L35): 0.74 (DC version)
    Heating (Traditional): >1473 BTU/HR (DC version)
    Heating (Din 3168): >432 WATTS (DC version)
    Cooling COP (at L35 L35): >1 (DC version)

      

    Includes:
    • Temperature controller
    • Mounting gasket
    • Mounting hardware
    • Power input cord

    Controller Features:
    TC-1F: Active cool 35 °C
    TC-6F: Active cool 25 °C or 35 °C
    TC-3F: Active cool 35 °C; Active heat 15 °C
    TC-7F: Active cool 35 °C; Active heat 15 °C; ECO-Mode 25 °C

  • Click on the part numbers to request a quick quote:
    NEMA-12/IndoorsNEMA-4/4X OutdoorsNEMA-4X/Harsh EnvironmentHaz. Loc.
    MODEL NUMBERPART NUMBERNOTESCONTROLLERVOLTAGE VAC (VDC)CURRENT AMPS
    AHP-18000-0180-0-000
    Cool onlyTC-6F1208
    AHP-18000-0150-0-000
    Cool only3-32 VDC External signal1208
    AHP-18000-01F0-0-000
    Cool onlyTC-1F1208
    AHP-1800HC0-0130-1-000
    Heat/CoolTC-3F1208
    AHP-1800HC0-0150-1-000
    Heat/Cool3-32 VDC External signal1208
    AHP-18020-0182-0-000
    Cool onlyTC-6F2405
    AHP-18020-0152-0-000
    Cool only3-32 VDC External signal2405
    AHP-18020-01F2-0-000
    Cool onlyTC-1F2405
    AHP-1802HC0-0132-1-000
    Heat/CoolTC-3F2405
    AHP-1802HC0-0152-1-000
    Heat/Cool3-32 VDC External signal2405
    AHP-18010-0181-0-000
    Cool onlyTC-6F120/2408.0/5.0
    AHP-18010-01F1-0-000
    Cool onlyTC-1F120/2408.0/5.0
    AHP-1801HC0-0131-1-000
    Heat/CoolTC-3F120/2408.0/5.0
    AHP-18000-0195-0-000
    Cool onlyNone(24)18
    AHP-18000-0185-0-000
    Cool onlyTC-6F(24)18
    AHP-18000-01F5-0-000
    Cool onlyTC-1F(24)18
    AHP-18000-0155-0-000
    Cool only3-32 VDC External signal(24)18
    AHP-1800HC0-0135-1-000
    Heat/CoolTC-3F(24)18
    AHP-1800HC0-01I5-1-000
    Heat/CoolTC-7F(24)18
    AHP-1800HC0-0155-1-000
    Heat/Cool3-32 VDC External signal(24)18
    AHP-1800HC0-01H5-1-000
    Heat/CoolTC-4600(24)18
    AHP-18000-0196-0-000
    Cool onlyNone(48)9
    AHP-18000-0186-0-000
    Cool onlyTC-6F(48)9
    AHP-18000-01F6-0-000
    Cool onlyTC-1F(48)9
    AHP-18000-0156-0-000
    Cool only3-32 VDC External signal(48)9
    AHP-1800HC0-0136-1-000
    Heat/CoolTC-3F(48)9
    AHP-1800HC0-01I6-1-000
    Heat/CoolTC-7F(48)9
    AHP-1800HC0-0156-1-000
    Heat/Cool3-32 VDC External signal(48)9
    MODEL NUMBERPART NUMBERNOTESCONTROLLERVOLTAGE VAC (VDC)CURRENT AMPS
    AHP-1800XE0-0180-4-000
    Cool onlyTC-6F1208
    AHP-1800XE0-0150-4-000
    Cool only3-32 VDC External signal1208
    AHP-1800XE0-01F0-4-000
    Cool onlyTC-1F1208
    AHP-1800XEHC0-0130-5-000
    Heat/CoolTC-3F1208
    AHP-1800XEHC0-0150-5-000
    Heat/Cool3-32 VDC External signal1208
    AHP-1802XE0-0182-4-000
    Cool onlyTC-6F2405
    AHP-1802XE0-0152-4-000
    Cool only3-32 VDC External signal2405
    AHP-1802XE0-01F2-4-000
    Cool onlyTC-1F2405
    AHP-1802XEHC0-0132-5-000
    Heat/CoolTC-3F2405
    AHP-1802XEHC0-0152-5-000
    Heat/Cool3-32 VDC External signal2405
    AHP-1800XE0-0195-4-000
    Cool onlyNone(24)18
    AHP-1800XE0-0185-4-000
    Cool onlyTC-6F(24)18
    AHP-1800XE0-01F5-4-000
    Cool onlyTC-1F(24)18
    AHP-1800XE0-0155-4-000
    Cool only3-32 VDC External signal(24)18
    AHP-1800XEHC0-0135-5-000
    Heat/CoolTC-3F(24)18
    AHP-1800XEHC0-01I5-5-000
    Heat/CoolTC-7F(24)18
    AHP-1800XEHC0-0155-5-000
    Heat/Cool3-32 VDC External signal(24)18
    AHP-1800XEHC0-01H5-5-000
    Heat/CoolTC-4600(24)18
    AHP-1800XE0-0196-4-000
    Cool onlyNone(48)9
    AHP-1800XE0-0186-4-000
    Cool onlyTC-6F(48)9
    AHP-1800XE0-01F6-4-000
    Cool onlyTC-1F(48)9
    AHP-1800XE0-0156-4-000
    Cool only3-32 VDC External signal(48)9
    AHP-1800XEHC0-0136-5-000
    Heat/CoolTC-3F(48)9
    AHP-1800XEHC0-01I6-5-000
    Heat/CoolTC-7F(48)9
    AHP-1800XEHC0-0156-5-000
    Heat/Cool3-32 VDC External signal(48)9
    MODEL NUMBERPART NUMBERNOTESCONTROLLERVOLTAGE VAC (VDC)CURRENT AMPS
    AHP-1800X0-0180-2-000
    Cool onlyTC-6F1208
    AHP-1800X0-0150-2-000
    Cool only3-32 VDC External signal1208
    AHP-1800X0-01F0-2-000
    Cool onlyTC-1F1208
    AHP-1800XHC0-0130-3-000
    Heat/CoolTC-3F1208
    AHP-1800XHC0-0150-3-000
    Heat/Cool3-32 VDC External signal1208
    AHP-1801X0-0181-2-000
    Cool onlyTC-6F120/2408.0/6.0
    AHP-1801X0-01F1-2-000
    Cool onlyTC-1F120/2408.0/6.0
    AHP-1801XHC0-0131-3-000
    Heat/CoolTC-3F120/2408.0/6.0
    AHP-1800X0-0195-2-000
    Cool onlyNone(24)18
    AHP-1800X0-0185-2-000
    Cool onlyTC-6F(24)18
    AHP-1800X0-01F5-2-000
    Cool onlyTC-1F(24)18
    AHP-1800X0-0155-2-000
    Cool only3-32 VDC External signal(24)18
    AHP-1800XHC0-0135-3-000
    Heat/CoolTC-3F(24)18
    AHP-1800XHC0-01I5-3-000
    Heat/CoolTC-7F(24)18
    AHP-1800XHC0-0155-3-000
    Heat/Cool3-32 VDC External signal(24)18
    AHP-1800XHC0-01H5-3-000
    Heat/CoolTC-4600(24)18
    AHP-1800X0-0196-2-000
    Cool onlyNone(48)9
    AHP-1800X0-0186-2-000
    Cool onlyTC-6F(48)9
    AHP-1800X0-01F6-2-000
    Cool onlyTC-1F(48)9
    AHP-1800X0-0156-2-000
    Cool only3-32 VDC External signal(48)9
    AHP-1800XHC0-0136-3-000
    Heat/CoolTC-3F(48)9
    AHP-1800XHC0-01I6-3-000
    Heat/CoolTC-7F(48)9
    AHP-1800XHC0-0156-3-000
    Heat/Cool3-32 VDC External signal(48)9
    MODEL PART NUMBER VOLTAGE    VAC 50/60 Hz CURRENT AMPS WEIGHT LBS. (KG) TEMP. CONTROL OPERATING AMBIENT TEMPERATURE RANGE C OPERATING ENCLOSURE TEMPERATURE RANGE C ENVIRONMENT
    AHP-1800EP 0-0180-0-002 120 8  46 (21)  TC-6F  -40/+63   -10/+60  NEMA-12
    AHP-1800EP 0-01F0-0-002 120 8  46 (21) TC-1F  -40/+63   -10/+60  NEMA-12
    AHP-1800EP-1 0-0170-0-004 120 8  46 (21) EXT*  -40/+63   -10/+60  NEMA-12
    AHP-1800EPHC  0-0130-1-003 120 8  46 (21) TC-3F  -40/+63   -10/+60  NEMA-12
    AHP-1800EPHC-1 0-0170-1-006 120 8  46 (21) EXT*  -40/+63   -10/+60  NEMA-12
    AHP-1800XEP 0-0180-4-002 120 8  46 (21)  TC-6F  -40/+63   -10/+60  NEMA-4/4X
    AHP-1800XEP 0-01F0-4-002 120 8  46 (21) TC-1F  -40/+63   -10/+60  NEMA-4/4X
    AHP-1800XEP-1 0-0170-4-004 120 8  46 (21) EXT*  -40/+63   -10/+60  NEMA-4/4X
    AHP-1800XEPHC  0-0130-5-003 120 8  46 (21) TC-3F  -40/+63   -10/+60  NEMA-4/4X
    AHP-1800XEPHC-1 0-0170-5-006 120 8  46 (21) EXT*  -40/+63   -10/+60  NEMA-4/4X
    AHP-1801EP 0-0181-0-002 120/240 8/5  46 (21)  TC-6F  -40/+63   -10/+60  NEMA-12
    AHP-1801EP 0-01F1-0-002 120/240 8/5  46 (21) TC-1F  -40/+63   -10/+60  NEMA-12
    AHP-1801EP-1 0-0171-0-002 120/240 8/5  46 (21) EXT*  -40/+63   -10/+60  NEMA-12
    AHP-1801EPHC  0-0131-1-003 120/240 8/5  46 (21) TC-3F  -40/+63   -10/+60  NEMA-12
    AHP-1801EPHC-1 0-0171-1-006 120/240 8/5  46 (21) EXT*  -40/+63   -10/+60  NEMA-12
    AHP-1801XEP 0-0181-4-002 120/240 8/5  46 (21)  TC-6F  -40/+63   -10/+60  NEMA-4/4X
    AHP-1801XEP 0-01F1-4-002 120/240 8/5  46 (21) TC-1F  -40/+63   -10/+60  NEMA-4/4X
    AHP-1801XEP-1 0-0171-4-002 120/240 8/5  46 (21) EXT*  -40/+63   -10/+60  NEMA-4/4X
    AHP-1801XEPHC  0-0131-5-003 120/240 8/5  46 (21) TC-3F  -40/+63   -10/+60  NEMA-4/4X
    AHP-1801XEPHC-1 0-0171-5-006 120/240 8/5  46 (21) EXT*  -40/+63   -10/+60  NEMA-4/4X
    AHP-1800XP 0-0180-2-002 120 8 47 (21.4)  TC-6F  -40/+75   -10/+60  NEMA-4X/Harsh
    AHP-1800XP 0-01F0-2-002 120 8 47 (21.4) TC-1F  -40/+75   -10/+60  NEMA-4X/Harsh
    AHP-1800XP-1 0-0170-2-004 120 8 47 (21.4) EXT*  -40/+75   -10/+60  NEMA-4X/Harsh
    AHP-1800XPHC 0-0130-3-003 120 8 47 (21.4) TC-3F  -40/+75   -10/+60  NEMA-4X/Harsh
    AHP-1800XPHC-1 0-0170-3-006 120 8 47 (21.4) EXT*  -40/+75   -10/+60  NEMA-4X/Harsh
    AHP-1801XP 0-0181-2-002 120/240 8/5 47 (21.4)  TC-6F  -40/+75   -10/+60  NEMA-4X/Harsh
    AHP-1801XP 0-01F1-2-002 120/240 8/5 47 (21.4) TC-1F  -40/+75   -10/+60  NEMA-4X/Harsh
    AHP-1801XP-1 0-0171-2-005 120/240 8/5 47 (21.4) EXT*  -40/+75   -10/+60  NEMA-4X/Harsh
    AHP-1801XPHC 0-0131-3-003 120/240 8/5 47 (21.4) TC-3F  -40/+75   -10/+60  NEMA-4X/Harsh
    AHP-1801XPHC-1 0-0171-3-004 120/240 8/5 47 (21.4) EXT*  -40/+75   -10/+60  NEMA-4X/Harsh

     

  • Click to download:

    Solid Model files:
    TypeFile NameDate ModifiedSize

    IGS
    AHP 1801 8:49 am 09/01/201624.8M

    STEP
    AHP 1801 8:49 am 09/01/201610.8M

    sldp
    AHP 1801 8:49 am 09/01/20162M

    SLDP
    AHP 1802XP 1:26 pm 08/01/201912.5M

    IGS
    Ahp 1800 8:48 am 09/01/201625.2M

    SLDP
    Ahp 1800 8:48 am 09/01/20162.3M

    STEP
    Ahp 1800 8:48 am 09/01/201610.9M

    dwg
    Ahp 1800 8:48 am 09/01/20162M

    pdf
    Ahp 1800 8:48 am 09/01/20161.1M

    dwg
    Ahp 1801 8:48 am 09/01/20162M

    pdf
    Ahp 1801 8:49 am 09/01/20161.1M
    Product Manuals:
    MA 1800 (113.9k)
    PIP 0-0150-1-000 ECN004C (630.1k)
    PIP 0-01F0-0-000 (2M)
    PIP 0-01F0-2-000 (2.1M)
    PIP 0-01F0-2-002 (1.2M)
    PIP 0-01F1-0-002 (1.3M)
    PIP 0-01F1-2-000 (1.6M)
    PIP 0-01F1-2-002 (1.2M)
    PIP 0-01F5-4-000 (731.1k)
    PIP 0-01H5-1-000 (860.6k)
    PIP 0-013C 5-000 (622.2k)
    PIP 0-0130-1-000 ECN004D (745.4k)
    PIP 0-0130-1-003 (1.2M)
    PIP 0-0130-3-000 ECN004C (769.5k)
    PIP 0-0130-3-003 ECN000A (1.2M)
    PIP 0-0130-3-003 ECN004D (1.3M)
    PIP 0-0130-5-000 ECN004D (880.5k)
    PIP 0-0130-5-003 (1.3M)
    PIP 0-0131-1-000 ECN007D (683.8k)
    PIP 0-0131-1-003 (1.3M)
    PIP 0-0131-3-000 ECN007C (696.3k)
    PIP 0-0131-3-003 ECN006D (3.3M)
    PIP 0-0132-1-000 ECN004E (815k)
    PIP 0-0132-5-000 ECN005E (972.2k)
    PIP 0-0135-1-000 (1.2M)
    PIP 0-0135-3-000 (1.2M)
    PIP 0-0135-5-000 (1.2M)
    PIP 0-0150-0-000 ECN004C (733.6k)
    PIP 0-0150-1-000 ECN004C (741.6k)
    PIP 0-0150-2-000 ECN004B (724.5k)
    PIP 0-0150-3-000 ECN004B (732.5k)
    PIP 0-0150-4-000 ECN004C (841.5k)
    PIP 0-0150-5-000 ECN004C (864.2k)
    PIP 0-0152-0-000 ECN004C (781.5k)
    PIP 0-0152-1-000 ECN004C (787.1k)
    PIP 0-0152-4-000 ECN005C (889.2k)
    PIP 0-0152-5-000 ECN005C (900.6k)
    PIP 0-0155-0-000 (1.2M)
    PIP 0-0155-1-000 (1.2M)
    PIP 0-0155-2-000 (1.2M)
    PIP 0-0155-3-000 (1.2M)
    PIP 0-0155-4-000 (1.2M)
    PIP 0-0155-5-000 (1.2M)
    PIP 0-0170-0-004 (1.2M)
    PIP 0-0170-1-006 (981.1k)
    PIP 0-0170-2-004 ECN004 (815.4k)
    PIP 0-0170-3-006 ECN004 (1.1M)
    PIP 0-0171-2-005 ECN004 (1.4M)
    PIP 0-0171-3-004 ECN008C (3.4M)
    PIP 0-0171-3-007 ECN002 (1.4M)
    PIP 0-0172-3-006 (1002k)
    PIP 0-0172-3-010 (1.5M)
    PIP 0-018C 4-000 (822.8k)
    PIP 0-0180-0-000 ECN004C (2.7M)
    PIP 0-0180-0-002 (985.1k)
    PIP 0-0180-2-000 ECN002B (1.2M)
    PIP 0-0180-2-002 ECN004C (1.1M)
    PIP 0-0180-4-000 ECN004C (911.8k)
    PIP 0-0181-0-000 ECN006D (655.3k)
    PIP 0-0181-0-001 (1.6M)
    PIP 0-0181-0-002 (1.6M)
    PIP 0-0181-2-000 ECN006C (685.3k)
    PIP 0-0181-2-002 ECN006D (3.3M)
    PIP 0-0181-2-008 ECN001A (980.9k)
    PIP 0-0182-0-000 ECN002B (1.6M)
    PIP 0-0182-2-007 (1.6M)
    PIP 0-0182-4-000 ECN005C (934.5k)
    PIP 0-0185-0-000 (1.3M)
    PIP 0-0185-2-000 (1.3M)
    PIP 0-0185-4-000 (1.3M)
    PIP 0-0195-0-000 (1.2M)
  • Part NumberDescriptionFor use with air conditioner seriesDrawingData Sheet
    EH-2001200 Watts Enclosure heater
    120 VAC
    dwgpdf
    EH-2002200 Watts Enclosure heater
    240 VAC
    dwgpdf
    EH-4001400 Watts Enclosure heater
    120 VAC
    dwgpdf
    EH-4002400 Watts Enclosure heater
    240 VAC
    dwgpdf
    DVA-1800Drip pan, vertical cold side finsAHP-1800, AHP-1801, AHP-1802dwgpdf
    DHA-1800Drip pan, horizontal cold side finsAHP-1800, AHP-1801, AHP-1802dwgpdf
    D-100Condensate discharge, plasticpdf
    D-200Condensate discharge, ST.ST.pdf
    MA-1800Mounting bracketAHP-1800, AHP-1801, AHP-1802pdf
    SP500-24Switching power supply
    500 Watts, 24 VDC
    pdf
    SP800-24Switching power supply
    800 Watts, 24 VDC
    pdf

Features:
• Compact, (18” L X 12.35” W X 9.69”D)
• Excels in high ambient temperatures
• Environmentally Safe
• Dual voltage versions available, consult factory.
• No compressor, fluorocarbons or filters
• Virtually maintenance-free operation
• Stainless steel exterior housing
• Versions to withstand corrosive environments,
shock and vibration
• Mounts and operates in any orientation
• Easy to use Pivot Clean feature
• Weight 52 LBS.
• Agency approvals: ETL Intertek


Resources:

Air conditioner Notes

Applications

Accessories

Manuals

Sizing Software

Contact Us

IHP-570 Series

Compact Internal Mount Thermoelectric Air Conditioner

Enclosure Cooling for NEMA-12, NEMA-4/4X, NEMA-4X/Harsh Environment 70 Watts (240 BTU/HR):

TECA’s IHP-570 Series air conditioner cools electrical cabinets and enclosures, protecting heat sensitive equipment from overheating. Utilizing reliable thermoelectric cooling technology, IHP-570 air conditioners are suitable for NEMA-12, NEMA-4/4X, and NEMA-4X/Harsh Environment in industries such as kiosk, communications, surveillance, food and beverage, transit, military and more. Internally mounted design offers closed loop cooling without cooling equipment extruding into the ambient. TECA’s air conditioners for NEMA-4X/Harsh Environment enclosure cooling use military grade fans for superior performance and reliability. Protect your investment with reliable and low maintenance Peltier (thermoelectric) coolers.


  • Mounting Style: Internal Mounted
    Voltage: 24 VDC
    Current: 3 AMPS, 0.3 AMPS (Eco-Mode)
    Operating Ambient: -40/+70 °C
    Operating Enclosure: -10/+60 °C
    Environments: Nema-12, Nema-4, Nema-4X/Harsh Environment

    Performance Rating:
    Cooling (Traditional):
    240 BTU/HR
    Cooling (Din 3168): 70 WATTS
    Cooling COP (at L35 L35): 0.97
    Heating (Traditional): > 245 BTU/HR
    Heating (Din 3168): > 72 WATTS
    Heating COP: > 1.0

    Includes:
    • Temperature controller
    • Mounting gasket
    • Mounting hardware
    • Power input leads
    • Power saving heat exchanger mode (ECO-Mode)

    Controller Features:
    TC-4F: Active cool 35 °C; ECO-Mode 25 °C
    TC-7F: Active cool 35 °C; Active heat 15 °C; ECO-Mode 25 °C

  • Click on the part numbers to request a quick quote:
    MODEL NUMBERPART NUMBERNOTESINSTALLATION STYLECONTROLLERENVIRONMENT
    IHP-570B-G0J5-0-000
    Cool onlyATC-4FIndoors
    IHP-570B-G0J5-0-100
    Cool onlyBTC-4FIndoors
    IHP-570HCB-G095-1-000
    Heat/CoolANoneIndoors
    IHP-570HCB-G095-1-100
    Heat/CoolBNoneIndoors
    IHP-570HCB-G0I5-1-000
    Heat/CoolATC-7FIndoors
    IHP-570HCB-G0I5-1-100
    Heat/CoolBTC-7FIndoors
    IHP-570XEB-G0J5-4-000
    Cool onlyATC-4FOutdoors
    IHP-570XEB-G0J5-4-100
    Cool onlyBTC-4FOutdoors
    IHP-570XEHCB-G095-5-000
    Heat/CoolANoneOutdoors
    IHP-570XEHCB-G095-5-100
    Heat/CoolBNoneOutdoors
    IHP-570XEHCB-G0I5-5-000
    Heat/CoolATC-7FOutdoors
    IHP-570XEHCB-G0I5-5-100
    Heat/CoolBTC-7FOutdoors
    IHP-570XB-G0J5-2-000
    Cool onlyATC-4FOutdoors/Military
    IHP-570XB-G0J5-2-100
    Cool onlyBTC-4FOutdoors/Military
    IHP-570XHCB-G095-3-000
    Heat/CoolANoneOutdoors/Military
    IHP-570XHCB-G095-3-100
    Heat/CoolBNoneOutdoors/Military
    IHP-570XHCB-B0I5-3-000
    Heat/CoolATC-7FOutdoors/Military
    IHP-570XHCB-G0I5-3-100
    Heat/CoolBTC-7FOutdoors/Military
  • Click to download:

    Solid Model files:
    TypeFile NameDate ModifiedSize

    IGS
    IHP 400-500 Style A 9:30 am 09/01/201652.6M

    PDF
    IHP 400-500 Style A 9:30 am 09/01/20163.4M

    SLDP
    IHP 400-500 Style A 9:30 am 09/01/20168.5M

    STEP
    IHP 400-500 Style A 9:30 am 09/01/201625.6M

    IGS
    IHP 400-500 Style B 9:31 am 09/01/201614.6M

    PDF
    IHP 400-500 Style B 9:31 am 09/01/20161.2M

    SLDP
    IHP 400-500 Style B 9:31 am 09/01/20163M

    STEP
    IHP 400-500 Style B 9:31 am 09/01/20168.5M
  • Part NumberDescriptionDrawingData Sheet
    DVA-500Drip pan, vertical cold side finsdwgpdf
    DHA-500Drip pan, horizontal cold side finsdwgpdf
    D-100Condensate discharge, plasticpdf
    D-200Condensate discharge, ST.ST.pdf
    AS150-12Switching power supply
    150 Watts, 12 VDC
    pdf
    AS150-24Switching power supply
    150 Watts, 24 VDC
    pdf
    SP300-12Switching power supply
    300 Watts, 12 VDC
    pdf
    SP300-24Switching power supply
    300 Watts, 24 VDC
    pdf

Features:
• Compact (only 17.4” X 8” X 7.8”)
• Mounts and operates in any orientation, inside enclosure
• Available in two installation styles:
– Style A: Installs from inside of the enclosure
– Style B: Installs from outside of the enclosure
• Low vibration and noise
• No moving parts except fans
• Environmentally safe
• No compressor, fluorocarbons or filters
• Virtually maintenance-free operation
• Stainless steel housing
• Efficient heat exchanger mode (ECO-Mode)
• Weight 16 LBS.


Resources:

Air conditioner Notes

Applications

Accessories

Manuals

Sizing Software

Contact Us

WELCOME TO TECA

TECA Corporation in Chicago began as a department of the Borg-Warner Corporation and developed the first commercially available thermoelectric enclosure cooler in 1978. A privately held company since 1984, TECA remains the market innovator of thermoelectric cooling products for industry, military, and laboratories.

We manufacture the broadest range of solid-state thermoelectric cooling products including air-conditioners, cold plates, liquid chillers, and custom assemblies. We proudly build all our products in our Chicago factory and ship directly to our customers around the globe. TECA is committed to using premium components from original source manufacturers and their certified distributors.


Our Customers

From small companies to global giants, from university laboratories to underground mining, our clients are incredibly diverse. We are grateful to be able to serve so many different industries. It is a testament to the value of thermoelectric cooling technology that it is used for so many purposes.

Some of the industries we most frequently serve include:

Automation Laboratory Military
Aerospace Life Science Oil & Gas
Communications Manufacturing R&D
Construction Engineering Satellite
Kiosk Healthcare Surveillance

Quality Mission Statement

The fundamental purpose of TECA is to serve its customers by providing world-class products of the best possible quality.
It is our promise to continually build with premium components from original source manufacturers and their licensed distributors.
It is our promise to continually monitor and improve our own operations.
It is our promise to meet and exceed our customers’ needs.


Guiding Values
Teamwork: Our success depends upon the safety, involvement, commitment, and performance of each team member.
Excellence: Without sacrificing health, safety, or the environment in which we live, we prioritize our efforts to ensure product quality and customer service.
Cooperation: Suppliers are a crucial factor of TECA quality. Their performance will be measured and controlled to ensure on-time, acceptable deliveries.
Accountability: We are dedicated to the continual improvement of our product offerings, our internal practices, and our customer relationships.

Quarterly eNewsletter