A major manufacturer of communications equipment was to go into production of special equipment enclosures, then encountered unforeseen problems with overheating electronics deep inside. The customer wanted air conditioning, but specified that no part of the air conditioner could protrude outside of their enclosure.

TECA designed a little air conditioner inside ducts for hot air exhaust. This way the air conditioner is actually housed entirely inside the enclosure and our customer continues production.

COMPACT MILITARY AIR CONDITIONER

Compact Military Air Conditioner:

compact military air conditioner

The contact to engineering read pretty much like this:

  • Wants A/C, 17.5 x 5.5 footprint, 150 W @ 0 Dt, He is in a hurry
  • Desert Application
  • Unit will require transport in, then it will sit for months, then it will go somewhere else
  • Single set point 35 °C control?
  • Size, can go 6″ on the outside

We suggested AHP-1200X, he said they didn’t choose because of no DC.  We could make it DC!  Nope, won’t fit, air flows are bad, 24 VDC, running off generator, NEMA 4X, Mil grade fans, 50 °C max, urgent need!

A little more than month later the order was placed and about 6 weeks after that a batch of custom air conditioners was being shipped.