The AHP-1200CPV is used in a customer’s Quality Control inspection process. The customer required a specific piece of equipment that would allow for bench top inspection of solution samples contained in small vials. Maintaining a 5C temperature throughout the QC inspection process was crucial.

Ease of use and dependable control by TECA Model AHP-1200CPV Cold Plate has made the customer’s process more efficient.

CONSUMER ELECTRONICS

Consumer electronics:

consumer electronics

They manufacture navigation devices for land, road, trail and water and they needed to evaluate circuit boards @ various temperatures (-30 °C to -40 °C, no or minimal heat load, room temperature ambient) and on recommendation of a person who joined them from a controls company and had been using the solid state cold plate AHP-1200CAS. The system required the cold plate, cascade, cascade control and tapped plate. The tapped plate is built into the cold plate in place of a smooth plate surface to attach to the cascade plate.

The cascade control facilitates power and temperature control to the cascade. The system also included an acrylic cover and insulation block. They received the system and liked how it is built.

HEARING AID

Hearing Aid:

hearing aid

A global leader in developing and manufacturing cochlear implant systems uses the AHP-1200CPV to cool down silicone molds after the curing process so the operators can safely handle the mold. So far the cold plate has been performing perfectly.

BROADCAST MICROWAVE SYSTEM

Broadcast Microwave System:

broadcast microwave system

Customer uses TECA AHP-1200CPV cold plate for a very accurate temperature control of a transmitter. The temperature of the unit under test is always the same, no matter what power it dissipates.

The thermal control loop works great and there is never a problem going cold or hot or switching power on or off.

CASCADE COLD PLATE

Cascade Cold Plate:

cascade cold plate cascade cold plate

 

Here’s a step by step of an AHP-1200CAS/CCP-22 Cascade system our engineers were playing with. They took a purple EasySep magnetic nano particle vessel, set it on the cascade, insulated it and then cycled it up and down for kicks. The curve shows the results. Faster times can be achieved by thinning out the plates and building the cascade into the AHP-1200CAS rather than having it as an option.

Talk to TECA engineers if your interested.

LABORATORY EQUIPMENT

Laboratory Equipment:

laboratory equipment laboratory equipment

A research organization had a problem with overheating of their equipment in a chemical-vapor deposition reactor TECA’s AHP-301CPV Cold Plate cooled the equipment and improved the performance of the customer’s system.

The customer was able to avoid system failures, which allowed the completion of a research project.

ANODIZING ALUMINUM

Anodizing Aluminum:

anodizing aluminum
A technological university in Asia chose TECA’ s thermoelectric cooling Model AHP-800MSP Magnetic Stirring Cold/Hot Plate to anodize aluminum. The researcher’s process required a temperature of 10 °C.

The AHP-800MSP‘s universal input voltage feature (100-240 VAC) allows it to be used anywhere, making it a perfect, off the shelf choice for our customer in Asia. He wrote to us: “It is quite good. Also the manual is quite clear and quite user-friendly. Thank you.”
Unique to this product is the adjustable nature of many of its features: stir-bar speed, fan speed (for noise reduction), temperature sensing (internal or external) and more.

The AHP-800MSP can even accept beakers of various size by adding optional sleeves. The solid-state thermoelectric construction is low-maintenance. There are no filters to change and no moving parts except for the fans. Our products use robust thermoelectric modules and boast a long service life.

QUICK COOLING OF A LOAD FROM 100 °C

Quick Cooling of a load from 100 °C

quick cooling quick cooling

 

A company specializing in hydrogen fuel cell technology required fast cooling of a fixture. The fixture is bonding multiple thin materials and can be heated up to 100 °C. The fixture needed to be cooled to the point where it could be handled by technicians—within a 5 minute time frame. Using two AHP-1200CP Cold Plates from TECA, the customer has created a system where a heat sink is cooled on one AHP-1200CP Cold Plate while a hot fixture is sandwiched between a second AHP-1200CP Cold Plate and a pre-cooled heat sink.

The customer reports being very happy with the TECA Cold Plates—the system is cooling in about 4 minutes!  The AHP-1200CP Cold Plate is an economical, easy to use product when maximum cooling is required, without a temperature controller. 120 VAC, 240 VAC and 24 VDC versions are available.

ELECTRONICS ENCLOSURE COOLING

Electronics Enclosure Cooling:

electronics enclosure cooling

Customer plans to use the TEC unit to regulate the temperature of some electronics in an outdoor enclosure. The electronics will be mounted to a cold plate where they can be cooled by direct contact with the TEC. The walls of the enclosure will be insulated to reduce thermal losses to the outside world. The hot side of the TEC will be in a separate, ventilated part of the enclosure to carry away waste heat. Customer will provide longitudinal air flow along the heat sink, so the built-in fan will not be necessary.

Originally considered using a solid-state air conditioner to cool the entire enclosure, but now prefers the direct-contact method for lower cooling requirements and smaller size. The active load that needs to be cooled is about 50 W. It will consist of a number of RF components (amps, sources, etc) mounted to a common cold plate. Several passive components will also be mounted to the plate. The whole temperature-controlled assembly will be insulated by an inch or so of foam or something similar. The ambient temperature range is roughly 0 to 100 °F at the extremes.

MANUFACTURING

Manufacturing:

manufacturing

Here’s another example of an AHP-1200CP thermoelectric cooler plate (Peltier cooler plate) used in a manufacturing station. The adjustable feet provide vertical flexibility in lining up the cold plate with the workstation. Parts slide easily from the hot plate to the work surface to the cold plate.