LOW TEMPERATURE CASCADE

Low Temperature Cascade

low temperature cascade

 

A cascade sandwich is what we called this that day, built using two AHP-300CP cold plates. The customer needed a fairly large mass cycle between two extremes. The mass and size of the load were limiting factors. The pictures and assembly look crude, and it was, but they were also effective.

It was determined that a final design based on standard components would be successful and it was.

The AHP-300CP series is now replaced by a newer and more efficient model the AHP-470CP series.

OEM LABORATORY EQUIPMENT

OEM Laboratory Equipment:

OEM laboratory equipment
AHP-150CP
OEM laboratory equipment
AHP-250CP

 

As a component in an OEM laboratory chamber, the AHP-150CP condenses out moisture to control humidity. The chamber is primarily used in hospital laboratories. The small size of the AHP-150CP helped reduce the footprint of the chamber and helped increase the work space within the chamber.

The AHP-150CP is maintenance free and the reliability of its thermoelectric cooling technology made our smallest cold plate the perfect OEM solution for this customer.

The AHP-150CP has been replaced by a newer and more efficient model the AHP-250CP series.

INDUSTRIAL ADHESIVE COOLING

Industrial Adhesive Cooling:

industrial adhesive cooling

These folks needed to cool a thick fluid that ends up being gaskets when robotically dispensed. A custom version of our AHP-1200CP fit the bill perfectly. Now the product is dispensed consistently because of the temperature control provided by thermoelectrics.

PORTABLE MEDICINE COOLER

Portable Medicine Cooler:

Portable medicine cooler needed for carrying emergency intravenous solutions, all components must be enclosed within the case. TECA designed a custom thermoelectric (peltier) based cold plate built into a Pelican™ Box.

portable medicine cooler portable medicine cooler box

 

TECA is developing this product for a new customer. We have taken a standard Pelican™ Box and configured a battery powered thermoelectric cooling system which is installed totally inside. This cooled box is for the purpose of transporting up to 4 liters of emergency intravenous solutions safely.

There are fitted compartments inside as well for transporting other necessary items for patient care. Since nothing is exposed or protruding from the box, our customer has ended up with a good looking and very rugged, functional thermoelectric product.

FLOW CHEMISTRY / OEM PRODUCT

Flow chemistry/OEM products application:

flow chemistry, cascaded thermoelectric cold plate

A European company specializing in equipment for the continuous flow chemistry market required extreme temperatures for a new product. Integrating a customized version of TECA’s Liquid Cooled Cascaded Cold Plate made the customer’s product possible: they are able to reach temperatures from minus 70 °C to plus 80 °C.

The customer reports that their new continuous flow reactor allows for the use of flow chemistry in many applications, achieving quicker results safely and with better control.

LIQUID CHILLER COLD PLATE CASCADE

Liquid Chiller Cold Plate Cascade:

Here are pictures of the TLC-900 thermoelectric liquid chiller with LHP-150CP Peltier liquid cooled cold plate set up run in the lab. The “load” is a plate with 10 power resistors mounted to the top and a series of thermocouples measuring the surface of the LHP-150CP’s thermoelectric cold plate.

liquid chiller cold plate cascade liquid chiller

 

During the test the power to the resistors is increased in steps with enough time in between for the temperatures to stabilize. Plotting the data resulted in performance curves. The test was made with the load insulated and with the load simply covered.

Later on we used a TLC-900CAS, a version of the TLC-900 made specifically for running and controlling secondary cold plates like the LHP-150CP and ran some step, ramp and soak profiles.

BEVERAGE COOLER

Beverage Cooler application:

beverage cooler system beverage cooler TE cooler

 

The beverage cooler application challenge was to keep concentrated beverage container located next to a hot water tank cool in a high volume OEM application. TECA has the flexibility and resources to manufacture custom OEM thermoelectric cooler (peltier coolers) assemblies intended for use as part of a customer machine, apparatus, or system. This OEM assembly is made by TECA in production runs in the thousands. It is not ours, so to protect the privacy and identity of our customers we can’t give too many details here.

This assembly is part of a beverage service product which is shipped worldwide by a well known consumer products company. TECA furnishes the cooling “engine” which refrigerates the beverage product to be dispensed, and the OEM builds finished machinery in their own plants.

FLUID DISPENSING

Fluid Dispensing:

fluid dispensing

A leading manufacturer of fluid dispensing systems uses one of our Thermoelectric Cold Plate and Temperature Controller for controlling the fluid temperature of adhesives, sealants, lubricants and other materials in meter, mix and dispensing systems.
Unlike other larger, higher cost and less accurate heating and cooling devices, which use heater cartridges, refrigerant or water to heat and cool, these thermoelectric-effect temperature controllers use the Peltier-Seebeck effect to directly convert electrical voltage to thermal differentials. This effect, which is reversible, either heats or cools fluid materials with precision to the temperature set point. The compact Peltier thermoelectric device, temperature sensor and the temperature control is mounted to a manifold where the fluid passes through to be precisely heated, maintained or cooled.

AHP-800MSP STIRRING COLD/HOT PLATE