SAMPLE COOLING IN CLEAN ROOM

Sample Cooling (Clean Room):

Sample Cooling Clean Room Sample Cooling Clean Room

 

A research lab in Europe needed to stabilize the temperature of an acid solution within +-0.5 °C. TECA’s AHP-301CPV Cold/Hot Plate was the ideal solution due to its small footprint, versatile features and programmable temperature controller. The customer offered the following comments:

  • The AHP-301CPV is installed in our big clean room*. Here we fabricate our micro/nano devices for electronic and photonic applications.
  • we have now the possibility to do experiments at controlled temperatures and in a really wide range of temperatures. This allow us to increase the reproducibility of our results, which often are so dependent by Temperature.
  • AHP-301CPV keeps stable the temperature of an acid solution inside a beaker (max 6 or 7cm in diameter and max 10cm in height).
  • The possibility to program the temperature controller it’s really interesting, and it will be worthwhile for future experiments. (The customer is referring to the ability to program ramp & soak profiles)

TECA’s cold/hot plates are not specifically designed for clean room use however the customer determined this product would be suitable given the restrictions in this particular clean room.

COOLING WAFER

Cooling Wafer:

The adjustable feet on this AHP-1200CP Peltier cooling plate (thermoelectric cooling plate) made life easier on the factory floor.

Customer wafers needed cooling at the end of processing and the feet brought the cold plate up to the perfect height to match the production mechanisms. Just a little option that TECA is ready to provide to make the products we build work for you.

INDUSTRIAL MATERIAL

Industrial Material:

industrial material

In this example of an AHP-1200CP application a box surrounds the cold plate area. Materials are set directly upon the cold plate and the lid is closed. The material is cooled and temperature controlled without the large air cooling refrigerator.

EQUIPMENT TESTING AND MAINTENANCE

Equipment Testing & Maintenance:

equipment testing

Three AHP-1200CPV Cold Plates are running continuously and in tandem at 17 °C to monitor satellite equipment. The customer has added air deflectors of his own design. TECA offers standard air deflectors as well. The customer applies approximately 50 Watts of heat to the cold plate.

QUALITY CONTROL

Quality Control:

quality control quality control

 

The AHP-1200CPV is used in a customer’s Quality Control inspection process. The customer required a specific piece of equipment that would allow for bench top inspection of solution samples contained in small vials. Maintaining a 5C temperature throughout the QC inspection process was crucial.

Ease of use and dependable control by TECA Model AHP-1200CPV Cold Plate has made the customer’s process more efficient.

CONSUMER ELECTRONICS

Consumer electronics:

consumer electronics

They manufacture navigation devices for land, road, trail and water and they needed to evaluate circuit boards @ various temperatures (-30 °C to -40 °C, no or minimal heat load, room temperature ambient) and on recommendation of a person who joined them from a controls company and had been using the solid state cold plate AHP-1200CAS. The system required the cold plate, cascade, cascade control and tapped plate. The tapped plate is built into the cold plate in place of a smooth plate surface to attach to the cascade plate.

The cascade control facilitates power and temperature control to the cascade. The system also included an acrylic cover and insulation block. They received the system and liked how it is built.

CASCADE COLD PLATE

Cascade Cold Plate:

cascade cold plate cascade cold plate

 

Here’s a step by step of an AHP-1200CAS/CCP-22 Cascade system our engineers were playing with. They took a purple EasySep magnetic nano particle vessel, set it on the cascade, insulated it and then cycled it up and down for kicks. The curve shows the results. Faster times can be achieved by thinning out the plates and building the cascade into the AHP-1200CAS rather than having it as an option.

Talk to TECA engineers if your interested.

3D PRINTING

3D Printing Process:

3d printing

A customer heard about TECA’s Thermoelectric Cold Plates through word-of-mouth and placed an order within a week. The AHP-301CP Cold Plate is used in the customer’s 3D printing process. Parts are printed on an aluminum plate which is then set on the AHP-301CP Cold Plate.

As the AHP-301CP Cold Plate cools the aluminum plate, the 3D prints just pop right off of the aluminum plate. The customer is pleased with the performance, ease of use and low purchase price of this basic model.

The AHP-301CP series is replaced by the newer AHP-401CP series.

COOLING LED CHIPS

Cooling LED Chips:

cooling led chips

The customer was looking for a cooling solution for LED chips. With a heat load as high as 45 watts at times, the customer needed to cool the chips quickly. The customer was able to utilize TECA’s Loaner Program and test the AHP-301CP cold plate before purchasing.

Satisfied with the AHP-301CP performance, the customer has since purchased several more and sold them as a part of his total system to his clients.

The AHP-301CP series is replaced by the newer and updated AHP-401CP series.

TITER PLATE COOLING

Titer Plate Cooling:

titer plate cooling AHP-300CP

The WWW brings many to TECA’s door. These particular customer requirements were filled by an AHP-300CP Peltier cold plate. He needed to control the temperature of a 96 well titer plate in a new product design. But he needed just a few things the standard unit didn’t provide and he didn’t need some that it did provide. He wanted a 24 VDC heat cool system with continuous fan operation and a custom tap pattern on the cold plate.

In short order the TECA sales team assigned a preliminary part number, passed the requirements through to engineering and together the first units were modified and shipped. This gave the customer plenty of time to work with the solid state cold plates and refine his requirements into the custom design he uses today.

The AHP-300CP series is now replaced by a newer and more efficient model the AHP-470CP series.

Quarterly eNewsletter