STIRRING COLD PLATE

Stirring Cold Plate:

A Peltier stirring cold plate was needed to cool liquid inside a standard 1000 ml plastic tank and maintain the class 100 clean room rating. They desired a custom designed thermoelectric stirring cold plate with integral variable stir speed control, temperature control, alarm and remote sense capability.

stirring cold plate stirring cold plate

TECA is glad to participate in custom and OEM product development. Over the years we have come up with some innovative and novel solutions for our customers. This product was developed from scratch for a start-up company in the field of pharmaceutical development. This TECA cold plate apparatus was designed and built for use in a clean room facility. The controls are ergonomic. The user can easily adjust controls for stir speed, timing and temperature even while wearing clean room garb and sterile gloves.

COOLING GAS FLOW

Cooling Gas FLow:

A potential customer expressed interest in a cooling/heating system for an aerosol flow tube envisioning a 1 inch OD, 0.875 inch ID stainless steel flow tube mounted inside a 2-2.5 inch ID pipe (likely also stainless steel and insulated on the outside) capable of controlling the tube at temperatures ranging from roughly 5 °C to 40 °C at an ambient temperature of 25-30 °C.  We are measuring the change in particulates in the air due to the temp change.

cooling gas flow cooling gas flow

Standard liquid chillers were first offered along with technical design assistance. The requirements led to direct contact cooling as being a good solution. Standard cold plate products and controllers were offered which led to this request for a custom package. “We would like to have the flow tube sandwiched between the cold plates with the temperature controller and power supplies attached in a similar manner so that we only need attach the temperature controller (the TC-3400 appears as if it will work) to a computer so that we can change the set points remotely.

Is any of this even possible or am I dreaming in Technicolor?” We advised him that the best dreams were in color. Preliminary design work was done and a quote prepared. Shortly thereafter an order was received; design documents were completed and sent to production. Less than 3 months after the initial contact the product was shipped. Several months later a follow up was made with this response.

“Things are doing really well. It does exactly what we wanted it to do, and is much more efficient and better than we hoped for. We’re very happy!

AHP-800MSP STIRRING COLD/HOT PLATE

COLD WELL

Cold Well:

cold well cold well

The CWB-01 cold well was first developed as an AHP-1200CPV custom accessory for the petrochemical industry. It replaced the need to maintain ice baths for the storage of chemicals. It has the advantage of good temperature control in either heating or cooling modes. The temperature of the cold plate can be referenced to the fluid temperature or the remote sensibility feature of the CPV can be used to control based on the actual fluid temperatures.

Cold Wells can be made to accommodate many vessel sizes.

COOLING FLUID FLOW

Cooling Fluid Flow:

cooling fluid flow cooling fluid flow

Chilling liquids being circulated by a peristaltic pump under ultra-clean conditions. When handling and processing various fluids in laboratory and electronic environments cleanliness is a must. Peristaltic pumps have been developed for the purpose of creating a fluid flow without contacting the fluid itself. TECA developed a liquid chiller to cool fluids, while satisfying the same cleanliness requirements.

The solution, based on our successful cold plate product line, has proven to be versatile and effective. Pictured here is the first prototype of a multiple-pass tube cooler for use with a peristaltic pump. Applications range from laboratory to medical to industrial.

R & D LABORATORY

R & D Laboratory:

r & d laboratory
An R&D laboratory needed to quickly cool beakers of high-concentration sucrose samples to 10 °C.  The customer reports that using TECA’s AHP-800MSP Magnetic Stirring Cold/Hot Plate system has been successful.

The customer has different sizes of samples, which are accommodated by TECA’s sleeve accessories. The customer uses 2L, 1.5L, 1L and 800mL sleeves at different times with the AHP-800MSP system. The sleeves are easy to switch in and out and add versatility to the system.

In fact, unique to this product is the adjustable nature of many of its features: stir-bar speed, fan speed (for noise reduction), and temperature sensing (internal or external).

CRYOGENIC FLUID CONTROL

Cryogenic Fluid Control:

cryogenic fluid control cryogenic fluid control

 

Cryogenic fluid is extremely sensitive to temperature and pressure changes within an experimental environment. A custom-modified version of TECA’s LHP-300CPHC Liquid-Cooled Cold Plate is installed as part of a system which allows the customer to closely monitor and control temperature.

The long life expectancy and low maintenance requirements of the LHP-300CPHC offer reliability and convenience to the customer’s long-term research experiment.