COOLING LED CHIPS

Cooling LED Chips:

cooling led chips

The customer was looking for a cooling solution for LED chips. With a heat load as high as 45 watts at times, the customer needed to cool the chips quickly. The customer was able to utilize TECA’s Loaner Program and test the AHP-301CP cold plate before purchasing.

Satisfied with the AHP-301CP performance, the customer has since purchased several more and sold them as a part of his total system to his clients.

The AHP-301CP series is replaced by the newer and updated AHP-401CP series.

TITER PLATE COOLING

Titer Plate Cooling:

titer plate cooling AHP-300CP

The WWW brings many to TECA’s door. These particular customer requirements were filled by an AHP-300CP Peltier cold plate. He needed to control the temperature of a 96 well titer plate in a new product design. But he needed just a few things the standard unit didn’t provide and he didn’t need some that it did provide. He wanted a 24 VDC heat cool system with continuous fan operation and a custom tap pattern on the cold plate.

In short order the TECA sales team assigned a preliminary part number, passed the requirements through to engineering and together the first units were modified and shipped. This gave the customer plenty of time to work with the solid state cold plates and refine his requirements into the custom design he uses today.

The AHP-300CP series is now replaced by a newer and more efficient model the AHP-470CP series.

LOW TEMPERATURE CASCADE

Low Temperature Cascade

low temperature cascade

 

A cascade sandwich is what we called this that day, built using two AHP-300CP cold plates. The customer needed a fairly large mass cycle between two extremes. The mass and size of the load were limiting factors. The pictures and assembly look crude, and it was, but they were also effective.

It was determined that a final design based on standard components would be successful and it was.

The AHP-300CP series is now replaced by a newer and more efficient model the AHP-470CP series.

COLD PROBE

Cold Probe Medical Application:

cold probe

A Medial Doctor was interested in a Peltier based “Cold Probe” to anesthetize the skin prior to treatment. He wanted an instrument that ran on batteries based around the Otoscope or the Ophthalmoscope with interchangeable heads. It was a medical application, a prototype and a long shot one at that.

He came to TECA with some rather limiting criteria to do a big job considering the load human skin presents. We did our best and gave the good Doctor his cold probe. We designed it, packaged it, powered it and built it. But not many folks really needed it. Not a complete market success but a technical one.

AVIONICS

Avionics cooling application:

avionics cold plate
avinoics TE cold plate

 

A branch of the US military had an overheating problem with a high-tech radio inside the wing of a fighter aircraft. TECA developed a custom, high-performance cold plate that withstand the shock, vibration, and G forces created by one of the most technically advanced aircraft.

In order to assure maximum strength with minimum weight, TECA’s Advanced Machining Center machines the finned heat sinks for each cooler from a single blocks of material

PORTABLE MEDICINE COOLER

Portable Medicine Cooler:

Portable medicine cooler needed for carrying emergency intravenous solutions, all components must be enclosed within the case. TECA designed a custom thermoelectric (peltier) based cold plate built into a Pelican™ Box.

portable medicine cooler portable medicine cooler box

 

TECA is developing this product for a new customer. We have taken a standard Pelican™ Box and configured a battery powered thermoelectric cooling system which is installed totally inside. This cooled box is for the purpose of transporting up to 4 liters of emergency intravenous solutions safely.

There are fitted compartments inside as well for transporting other necessary items for patient care. Since nothing is exposed or protruding from the box, our customer has ended up with a good looking and very rugged, functional thermoelectric product.

NEUROSCIENCE RESEARCH

Neuroscience Research:

neuroscience research

 

At a prominent U.S. university, neuroscience research team choose TECA’s economical AHP-270CP Cold Plate.

The customer reports: “We cool a fly to 8 deg Celsius, and also use vacuum to attach it to the device during a brain dissection procedure. Essentially, the cooling is anesthetizing the fly, making it possible to attach the fly to the dissecting chamber in a very precise manner, using a manipulator (also in the picture).” The AHP-270CP is a great solution because it is small, inexpensive and yet offers reliable and effective cooling on the bench top.

FLOW CHEMISTRY / OEM PRODUCT

Flow chemistry/OEM products application:

flow chemistry, cascaded thermoelectric cold plate

A European company specializing in equipment for the continuous flow chemistry market required extreme temperatures for a new product. Integrating a customized version of TECA’s Liquid Cooled Cascaded Cold Plate made the customer’s product possible: they are able to reach temperatures from minus 70 °C to plus 80 °C.

The customer reports that their new continuous flow reactor allows for the use of flow chemistry in many applications, achieving quicker results safely and with better control.

TISSUE DISSECTION

Tissue Dissection Application:

AHP-1200CAS used in tissue dissection

We used TECA’s AHP-1200CAS three stage cascaded thermoelectric cold plate system to facilitate dissection of frozen human postmortem brain slices for extraction of protein for Proteomics research. Because we were trying to select specific regions without damaging the rest of each small specimen, it was important for us to maintain the integrity of the specimen during dissection.

Working in a lab at normal room temperature, we found that a constant temperature of -18 °C was ideal for this work (-20 °C was too cold, and warmer than -18  °C made the tissue start to melt). It would have been impossible to maintain such a precise temperature outside of a Cryostat without the cold table. It was immensely easier to perform the dissection on the cold table, and of course also much easier to wipe down the cold table than to clean a Cryostat.

LIQUID CHILLER COLD PLATE CASCADE

Liquid Chiller Cold Plate Cascade:

Here are pictures of the TLC-900 thermoelectric liquid chiller with LHP-150CP Peltier liquid cooled cold plate set up run in the lab. The “load” is a plate with 10 power resistors mounted to the top and a series of thermocouples measuring the surface of the LHP-150CP’s thermoelectric cold plate.

liquid chiller cold plate cascade liquid chiller

 

During the test the power to the resistors is increased in steps with enough time in between for the temperatures to stabilize. Plotting the data resulted in performance curves. The test was made with the load insulated and with the load simply covered.

Later on we used a TLC-900CAS, a version of the TLC-900 made specifically for running and controlling secondary cold plates like the LHP-150CP and ran some step, ramp and soak profiles.