OEM LABORATORY EQUIPMENT

OEM Laboratory Equipment:

OEM laboratory equipment
AHP-150CP
OEM laboratory equipment
AHP-250CP

 

As a component in an OEM laboratory chamber, the AHP-150CP condenses out moisture to control humidity. The chamber is primarily used in hospital laboratories. The small size of the AHP-150CP helped reduce the footprint of the chamber and helped increase the work space within the chamber.

The AHP-150CP is maintenance free and the reliability of its thermoelectric cooling technology made our smallest cold plate the perfect OEM solution for this customer.

The AHP-150CP has been replaced by a newer and more efficient model the AHP-250CP series.

LIQUID COOLED COLD PLATE

Liquid Cooled Cold Plate:

liquid cooled cold plate

Our customer asked for a quote on delivery and price for the LHP-800CPHC. He then asked if we had a liquid cooled version of the AHP-1200CPHC (15″ x 7.3″ plate)? The product had been in the works but on the back burner. This customers request pulled it to the front.

We offered an LHP1200CP. It would be liquid cooled with 15 x 7.3 cold plate requiring 24 VDC input. The customer later set it up with a water pump and a radiator/fan arrangement to provide a recirculation cooling water path rather than connecting to the tap and sending it down the drain.

INDUSTRIAL ADHESIVE COOLING

Industrial Adhesive Cooling:

industrial adhesive cooling

These folks needed to cool a thick fluid that ends up being gaskets when robotically dispensed. A custom version of our AHP-1200CP fit the bill perfectly. Now the product is dispensed consistently because of the temperature control provided by thermoelectrics.

NEUROSCIENCE RESEARCH

Neuroscience Research:

neuroscience research

 

At a prominent U.S. university, neuroscience research team choose TECA’s economical AHP-270CP Cold Plate.

The customer reports: “We cool a fly to 8 deg Celsius, and also use vacuum to attach it to the device during a brain dissection procedure. Essentially, the cooling is anesthetizing the fly, making it possible to attach the fly to the dissecting chamber in a very precise manner, using a manipulator (also in the picture).” The AHP-270CP is a great solution because it is small, inexpensive and yet offers reliable and effective cooling on the bench top.

TISSUE DISSECTION

Tissue Dissection Application:

AHP-1200CAS used in tissue dissection

We used TECA’s AHP-1200CAS three stage cascaded thermoelectric cold plate system to facilitate dissection of frozen human postmortem brain slices for extraction of protein for Proteomics research. Because we were trying to select specific regions without damaging the rest of each small specimen, it was important for us to maintain the integrity of the specimen during dissection.

Working in a lab at normal room temperature, we found that a constant temperature of -18 °C was ideal for this work (-20 °C was too cold, and warmer than -18  °C made the tissue start to melt). It would have been impossible to maintain such a precise temperature outside of a Cryostat without the cold table. It was immensely easier to perform the dissection on the cold table, and of course also much easier to wipe down the cold table than to clean a Cryostat.

LIQUID CHILLER COLD PLATE CASCADE

Liquid Chiller Cold Plate Cascade:

Here are pictures of the TLC-900 thermoelectric liquid chiller with LHP-150CP Peltier liquid cooled cold plate set up run in the lab. The “load” is a plate with 10 power resistors mounted to the top and a series of thermocouples measuring the surface of the LHP-150CP’s thermoelectric cold plate.

liquid chiller cold plate cascade liquid chiller

 

During the test the power to the resistors is increased in steps with enough time in between for the temperatures to stabilize. Plotting the data resulted in performance curves. The test was made with the load insulated and with the load simply covered.

Later on we used a TLC-900CAS, a version of the TLC-900 made specifically for running and controlling secondary cold plates like the LHP-150CP and ran some step, ramp and soak profiles.

STIRRING COLD PLATE

Stirring Cold Plate:

A Peltier stirring cold plate was needed to cool liquid inside a standard 1000 ml plastic tank and maintain the class 100 clean room rating. They desired a custom designed thermoelectric stirring cold plate with integral variable stir speed control, temperature control, alarm and remote sense capability.

stirring cold plate stirring cold plate

TECA is glad to participate in custom and OEM product development. Over the years we have come up with some innovative and novel solutions for our customers. This product was developed from scratch for a start-up company in the field of pharmaceutical development. This TECA cold plate apparatus was designed and built for use in a clean room facility. The controls are ergonomic. The user can easily adjust controls for stir speed, timing and temperature even while wearing clean room garb and sterile gloves.

COOLING FLUID FLOW

Cooling Fluid Flow:

cooling fluid flow

A customer needed to cool high pressure flow of fluid in a single pass. Using expanded Aluminum foam and attaching it to the surface of AHP-301CP thermoelectric cold plate (peltier cold plate) provided a way to maximize the thermal contact surface and eliminated the need to complex fluid path and larger cold plate.

FLUID DISPENSING

Fluid Dispensing:

fluid dispensing

A leading manufacturer of fluid dispensing systems uses one of our Thermoelectric Cold Plate and Temperature Controller for controlling the fluid temperature of adhesives, sealants, lubricants and other materials in meter, mix and dispensing systems.
Unlike other larger, higher cost and less accurate heating and cooling devices, which use heater cartridges, refrigerant or water to heat and cool, these thermoelectric-effect temperature controllers use the Peltier-Seebeck effect to directly convert electrical voltage to thermal differentials. This effect, which is reversible, either heats or cools fluid materials with precision to the temperature set point. The compact Peltier thermoelectric device, temperature sensor and the temperature control is mounted to a manifold where the fluid passes through to be precisely heated, maintained or cooled.