COLD PROBE

Cold Probe Medical Application:

cold probe

A Medial Doctor was interested in a Peltier based “Cold Probe” to anesthetize the skin prior to treatment. He wanted an instrument that ran on batteries based around the Otoscope or the Ophthalmoscope with interchangeable heads. It was a medical application, a prototype and a long shot one at that.

He came to TECA with some rather limiting criteria to do a big job considering the load human skin presents. We did our best and gave the good Doctor his cold probe. We designed it, packaged it, powered it and built it. But not many folks really needed it. Not a complete market success but a technical one.

CUSTOM COLD PLATE

Custom Cold Plate Application:

custom cold plate

The people at MIT who wanted a custom cold plate with plain black anodized cold plate never did tell us what it was for. We think maybe they are using it to calibrate or adjust infra red temperature detectors. We could be wrong. They might have thought it just looked cool.

For whatever reason, they told us what they wanted and we did our best to meet their requirement.

NEUROSCIENCE RESEARCH

Neuroscience Research:

neuroscience research

 

At a prominent U.S. university, neuroscience research team choose TECA’s economical AHP-270CP Cold Plate.

The customer reports: “We cool a fly to 8 deg Celsius, and also use vacuum to attach it to the device during a brain dissection procedure. Essentially, the cooling is anesthetizing the fly, making it possible to attach the fly to the dissecting chamber in a very precise manner, using a manipulator (also in the picture).” The AHP-270CP is a great solution because it is small, inexpensive and yet offers reliable and effective cooling on the bench top.

FLOW CHEMISTRY / OEM PRODUCT

Flow chemistry/OEM products application:

flow chemistry, cascaded thermoelectric cold plate

A European company specializing in equipment for the continuous flow chemistry market required extreme temperatures for a new product. Integrating a customized version of TECA’s Liquid Cooled Cascaded Cold Plate made the customer’s product possible: they are able to reach temperatures from minus 70 °C to plus 80 °C.

The customer reports that their new continuous flow reactor allows for the use of flow chemistry in many applications, achieving quicker results safely and with better control.

LIQUID CHILLER COLD PLATE CASCADE

Liquid Chiller Cold Plate Cascade:

Here are pictures of the TLC-900 thermoelectric liquid chiller with LHP-150CP Peltier liquid cooled cold plate set up run in the lab. The “load” is a plate with 10 power resistors mounted to the top and a series of thermocouples measuring the surface of the LHP-150CP’s thermoelectric cold plate.

liquid chiller cold plate cascade liquid chiller

 

During the test the power to the resistors is increased in steps with enough time in between for the temperatures to stabilize. Plotting the data resulted in performance curves. The test was made with the load insulated and with the load simply covered.

Later on we used a TLC-900CAS, a version of the TLC-900 made specifically for running and controlling secondary cold plates like the LHP-150CP and ran some step, ramp and soak profiles.

STIRRING COLD PLATE

Stirring Cold Plate:

A Peltier stirring cold plate was needed to cool liquid inside a standard 1000 ml plastic tank and maintain the class 100 clean room rating. They desired a custom designed thermoelectric stirring cold plate with integral variable stir speed control, temperature control, alarm and remote sense capability.

stirring cold plate stirring cold plate

TECA is glad to participate in custom and OEM product development. Over the years we have come up with some innovative and novel solutions for our customers. This product was developed from scratch for a start-up company in the field of pharmaceutical development. This TECA cold plate apparatus was designed and built for use in a clean room facility. The controls are ergonomic. The user can easily adjust controls for stir speed, timing and temperature even while wearing clean room garb and sterile gloves.

COOLING FLUID FLOW

Cooling Fluid Flow:

cooling fluid flow

A customer needed to cool high pressure flow of fluid in a single pass. Using expanded Aluminum foam and attaching it to the surface of AHP-301CP thermoelectric cold plate (peltier cold plate) provided a way to maximize the thermal contact surface and eliminated the need to complex fluid path and larger cold plate.

BEVERAGE COOLING IN A BARREL

Beverage Cooling in a barrel:

beverage cooling in a barrel beverage cooling in a barrel

Here’s an application that TECA’s engineering team was particularly excited about. Not because of the economics or the potential new business. Frankly we didn’t think the market was there. But as soon as they found out that a ½ barrel of beer would be needed for testing they were all over it. While none was ever sold, good lessons regarding contact methods and material stratification were learned. To see the result of the test click here.
We used an AHP-1200CP thermoelectric cold plate and a TLC-700 thermoelectric liquid chiller for testing purpose.

AHP-800MSP STIRRING COLD/HOT PLATE

COLD WELL

Cold Well:

cold well cold well

The CWB-01 cold well was first developed as an AHP-1200CPV custom accessory for the petrochemical industry. It replaced the need to maintain ice baths for the storage of chemicals. It has the advantage of good temperature control in either heating or cooling modes. The temperature of the cold plate can be referenced to the fluid temperature or the remote sensibility feature of the CPV can be used to control based on the actual fluid temperatures.

Cold Wells can be made to accommodate many vessel sizes.